Description

5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections).Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    Culvert

    Notice bb96c3149fbc427fbb1d5490a1f639b7 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationCurrent

    Culvert

    Notice 15f7c39798ef49af91118f94e96c3710 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections). Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering.
100%
Combined Synopsis06/22/2026
5? wide x 6? high x 57.1? length Box Culvert to include:Approximately (57.1) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8 sections).Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprenegaskets will be installed on each box section prior to delivery. Exterior waterproofing byothers. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PEstamp w/ supporting Calculations provided). Drawings/submittals stamped by a PElicensed in NY with supporting engineering
100%
Combined Synopsis02/03/2026
Amended to change NAICS code. RCP, ASTM C-76 (8ft Lengths)30in RCP, Class 4, O-Ring Gasket (64 ft) 30in Flared End Section - Bell Connection (2 ea) 30in Flared End Section - Spigot Connection (2 ea) RCP, ASTM C-76 (8ft Lengths), 24in RCP, Class 4, O-Ring Gasket (40ft) 24in Flared End Section - Bell Connection (1ea) 24in Flared End Section - Spigot Connection (1 ea)
74%
Combined Synopsis06/03/2026
40FT CLASS 3 STEEL POLE
48%
Combined Synopsis11/16/2026
40FT CLASS 3 STEEL POLE
48%
Combined Synopsis11/16/2026

Additional Details

Solicitation Number

W911S226U3116

Archive Date

May 11, 2027

Office Address

FORT DRUM, NY, 13602-5220