Notice ID: ff669974393f44dcb36dd46c10ae57e8Combined Synopsis/Solicitation
Culvert
Responses closed . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM EDT
- Posted
- May 27, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 331210: Iron and Steel Pipe and Tube Manufacturing from Purchased Steel
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
- Place of performance
- 4525 Camp Hale Rd Fort Drum, NY 13602 , 13602
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W911S226U3320
- Notice ID
- ff669974393f44dcb36dd46c10ae57e8
Description
Amended to change NAICS code. RCP, ASTM C-76 (8ft Lengths)30in RCP, Class 4, O-Ring Gasket (64 ft) 30in Flared End Section - Bell Connection (2 ea) 30in Flared End Section - Spigot Connection (2 ea) RCP, ASTM C-76 (8ft Lengths), 24in RCP, Class 4, O-Ring Gasket (40ft) 24in Flared End Section - Bell Connection (1ea) 24in Flared End Section - Spigot Connection (1 ea)
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for W911S226U3320piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 1
- 2Version 2Combined Synopsis/SolicitationCurrent
Culvert
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections). Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering. | 74% | Combined Synopsis | 06/22/2026 |
5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections).Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering. | 74% | Combined Synopsis | 05/13/2026 |
5? wide x 6? high x 57.1? length Box Culvert to include:Approximately (57.1) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8 sections).Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprenegaskets will be installed on each box section prior to delivery. Exterior waterproofing byothers. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PEstamp w/ supporting Calculations provided). Drawings/submittals stamped by a PElicensed in NY with supporting engineering | 74% | Combined Synopsis | 02/03/2026 |
40FT CLASS 3 STEEL POLE | 48% | Combined Synopsis | 11/16/2026 |
40FT CLASS 3 STEEL POLE | 48% | Combined Synopsis | 11/16/2026 |
Additional Details
Solicitation Number
W911S226U3320
Archive Date
May 27, 2027
Office Address
FORT DRUM, NY, 13602-5220