Notice ID: c1c6f8bca5cc41568697b63693498e5eSolicitationArchived
N--Minuteman National Historical Park- FARWELL JONES
Archived on February 7, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM EST
- Posted
- January 23, 2026
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of the InteriorNATIONAL PARK SERVICE
Notice details
- Office
- NER SERVICES MABO (43000)
- Place of performance
- Concord, 01742
- Last updated
- Nov 3, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 140P4326R0003
- Notice ID
- c1c6f8bca5cc41568697b63693498e5e
Description
Minuteman National Historical Park FARWELL JONES BOILER REPLACEMENT
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (7)
- Download
Sol_140P4326R0003_Amd_0001.pdf
202 KBAdded in Solicitation version 3Posted - Download
Attachment_5_-_Mechanical_Plans_0001.pdf
532 KBAdded in Solicitation version 3Posted - Download
RFIs_1-18_0001.pdf
168 KBAdded in Solicitation version 3Posted - Download
Sol_140P4326R0003.pdf
965 KBAdded in Solicitation version 1Posted - Download
B08_Attachment_1_-_Scope_of_Work.pdf
5.9 MBAdded in Solicitation version 1Posted - Download
B08_Attachment_2_-_Davis-Bacon_Wage_Determination_MA20260004.pdf
4.1 MBAdded in Solicitation version 1Posted - Download
B08_Attachment_3_-_Construction_Contract_Administration.pdf
104 KBAdded in Solicitation version 1Posted
Lifecycle
- 1Version 1SolicitationArchived
Minuteman National Historical Park- FARWELL JONES
- 3Version 3SolicitationArchivedCurrent
N--Minuteman National Historical Park- FARWELL JONES
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
See attached JOFOC | 55% | Sole Source / J&A | Open |
Questions and Answers 36C24727Q0050 Boiler #3 Oxygen Analyzer and Steam Flow Meter RFI Responses Where should the output signals from the new steam flow meter and O2 analyzer terminate? For example, the existing building automation system (BAS), the existing Boiler 3 burner/boiler controls, or a local display only. Burner 3 boiler/burner controls where applicable and local display. Does the government require active O2 trim control to the burner fuel/air ratio, or monitoring and display of the O2 only? Oxygen analyzer must send signals/information to combustion controls to control trim. What is the material of construction for the stack? Is it single or double wall? Stack is double walled. Inside material is steel; outside material is galvanized steel. Stack is 36 D Selkirk Metalbestos Model P.S. Current operating pressure and temperature of the system for boiler #3? Design pressure is 200 psi. Typical operating pressure is 82 psi. Typical operating temperature is about 330 degrees Fahrenheit. What are the available outputs on the physical steam flow meter (e.g., 4-20 mA, Modbus RTU, BACnet MS/TP)? 4-20 mA analog. Is the flow meter wired directly into an analog terminal block on the CB Hawk, or is it wired directly to the facility s Building Automation System (BMS)? Steam flow meter is wired into local CB Hawk analog terminal block. Please provide nameplates for the existing oxygen analyzer and steam flow meter. Oxygen analyzer nameplate: Steam flow meter nameplate: | 55% | Combined Synopsis | 10/26/2026 |
Amendment 0001 - Add Comments Matrix as of 11/06/2026. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 12445127B0002 is issued as an Invitation for Bid (IFB) for Halfmoon Ranch House HVAC Installation. This project involves installing three ductless, split unit climate control system in Halfmoon Ranch, a historic house located in a remote and rural location. Currently there is no climate control system in the building. This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220 The small business size standard is $19M This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency. | 53% | Combined Synopsis | 12/07/2026 |
The United States Coast Guard Deputy Commandant for Systems (DCS) is issuing this combined synopsis/solicitation on behalf of the Surface Forces Logistics Center (SFLC) to award a firm-fixed-price service contract, as detailed in the attached Statement of Work. This requirement consists of performing all on-site labor and services to remove the existing fire suppression system and install a new water mist system and fire alarm control panel in support of the USCGC SCIOTO. All work must be performed on-site at 221 Mississippi Drive, Keokuk, IA 52632. The planned Period of Performance (PoP) is from 15Nov26 through 23Nov26. This acquisition is a 100% total small business set-aside under NAICS code 238220, with a corresponding small business size standard of $19.0 million. The applicable Product Service Code is N042. The Government will award a contract resulting from this solicitation to the responsible offeror whose quote conforming to the solicitation is most advantageous to the Government, price and other factors considered. The following factors will be used to evaluate offers: 1. Technical Capability (Pass/Fail) 2. Past Performance (Pass/Fail) 3. Total Price A quotation must receive an Acceptable rating for all non-price factors to be eligible for award. Among all acceptable quotations, award will be made to the responsible offeror submitting the lowest evaluated price. To establish Technical Capability (Pass/Fail), the quotation must demonstrate a clear understanding of the work statement requirements, conform strictly to all specifications in the attached Statement of Work, and provide any adequate capability and corporate experience documentation required by the solicitation. Failure to meet these criteria will render the quotation unacceptable. The Government will evaluate recent (completed within the last three years) and relevant past performance to assess the likelihood of successful performance. Past performance will be evaluated on an acceptable or unacceptable basis. To receive an acceptable rating, past performance must demonstrate a rating of satisfactory or higher performance of similar work. Offerors without recent or relevant past performance will be assessed as "Neutral" and considered acceptable for award. Past performance demonstrating marginal or below performance is unacceptable. Offerors shall identify all subcontractors anticipated to perform work under this contract. For each subcontractor, the offeror shall provide the subcontractor’s name, address, point of contact, phone number, the specific work items/specifications they will perform, and the percentage of work they will execute. Submit offers electronically via email to the points of contact identified in this notice. The Government does not prescribe a specific quotation format. Offerors must submit a quotation that clearly identifies the items offered and demonstrates compliance with the stated requirements. Submissions must be complete, clear, and presented in a format that allows effective evaluation by the Government. Submit all questions via email to the points of contact identified in this notice. The Government will not accept telephone inquiries. Submit offers on a firm-fixed-price basis. Prices must be all-inclusive and must cover all costs associated with providing the services, including but not limited to manufacturing, packaging, handling, transportation, duties, tariffs, fees, and any other costs. The Government may consider offers nonresponsive if they include conditional pricing, price escalation language, or statements indicating that prices are subject to adjustment based on future costs or fees. The Government intends to evaluate offers and make award without discussions; therefore, offerors should submit their best offer with initial submission. The Statement of Work and the list of applicable FAR provisions and clauses are attached to this notice. | 53% | Combined Synopsis | 11/09/2026 |
Watervliet Arsenal (WVA) Replacement of the 300 Line Chrome Piping. See attached Request for Quote (RFQ) for complete details. | 53% | Solicitation | 10/29/2026 |
Additional Details
Solicitation Number
140P4326R0003
Archive Date
Feb 7, 2026
Office Address