GovChime
Notice ID: 21dd481362824e8ca29ea8a25bda2840SolicitationArchived

Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

Archived on July 30, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:00 PM EDT
Posted
April 9, 2026
Notice type
Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
236220: Commercial and Institutional Building Construction
Agency
Department of Veterans Affairs

Notice details

Office
241-NETWORK CONTRACT OFFICE 01 (36C241)
Place of performance
Brockton, Massachusetts, 02301
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24126Q0250
Notice ID
21dd481362824e8ca29ea8a25bda2840

Description

The Building 4 Elevator Replacement will take place at Building 4 of the Brockton VA Healthcare System Campus in Brockton, MA. The project will consist of Modernization of existing elevators; (1) passenger 3 stop elevator and (1) service 3 stop elevator and associated work necessary to support project. Elevator modernization and associated work. Work includes general construction, alterations, indicators, calls and notification systems, minor site preparation for access and staging and work to support enclosed elevator machine room in existing penthouse. Necessary removal of existing structures and construction and certain other items. The work shall include all demolition and construction necessary to execute the project as defined in the construction documents and as may be implied from the intended use. Removal of regulated building materials shall be conducted in accordance with abatement procedures as per Report (attached). All electrical work necessary for the Modernization of existing elevators must be executed by a Massachusetts licensed electrical contractor. All mechanical work necessary for the Modernization of existing elevators must be executed by a Massachusetts licensed mechanical contractor. All elevators work necessary for the Modernization of existing elevators must be executed by a Massachusetts licensed Class C11 Elevator contractor. The general contractor is responsible for ensuring all technicians involved have Certified Elevator Technicians (CETs) and contractor furnished elevator inspectors possess Qualified Elevator Inspector (QEI) certifications through the ANSI National Accreditation Board and National Association of Elevator Contractors (NAEC). Complete the work within 365 calendar days from the tentative NTP of May 2026. Scope considerations include coordinating with VA Facilities staff, obtaining necessary permits, scheduling work, keeping the site clean, and complying with all applicable regulations and codes. All materials and shop drawings must be approved by the COR, and work must follow Massachusetts DLS regulations and OSHA codes. The period of performance for the project is 365 Calendar Days.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Sep 13, 2024

NAICS

236220

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Sean D Genereux
Contract Specialist

Documents

Files (22)

  • Sign-In Sheet - 523A5-18-371 - Building 4 Elevator Replacement - Solictation Walkthru 10MARCH26.pdf

    434 KBAdded in Solicitation version 9Posted
    Download
  • Site Visit Form - 523A5-18-371 - Building 4 Elevator Replacement - Solicitation Walkthru 10MARCH26.docx

    19 KBAdded in Solicitation version 9Posted
    Download
  • 26_0327-4.GI000-Add2 B4Elev 523A5-18-371.pdf

    2.5 MBAdded in Solicitation version 9Posted
    Download
  • 26_0327-4.AS803-Add2 B4Elev 523A5-18-371.pdf

    2.1 MBAdded in Solicitation version 9Posted
    Download
  • S06 VHA PCRA 2024 1 COR 002.pdf

    498 KBAdded in Solicitation version 9Posted
    Download
  • 26_0327-4.GI110-Add2 B4Elev 523A5-18-371.pdf

    463 KBAdded in Solicitation version 9Posted
    Download
  • S06 VHA ICRA-1 3 Jan 3 2025.pdf

    295 KBAdded in Solicitation version 9Posted
    Download
  • 26_0327-Spec-087100-Add2 B4Elev 523A5-18-371.pdf

    136 KBAdded in Solicitation version 9Posted
    Download
  • S06 36C24126Q0250 0002.docx

    133 KBAdded in Solicitation version 9Posted
    Download
  • 26_0327-Cover-Add2 B4Elev 523A5-18-371.pdf

    49 KBAdded in Solicitation version 9Posted
    Download
  • 26_0327-Spec-000110-Add2 B4Elev 523A5-18-371.pdf

    130 KBAdded in Solicitation version 9Posted
    Download
  • 36C24126Q0250 0001.pdf

    373 KBAdded in Solicitation version 5Posted
    Download
  • WAGE DETERMINATION MA20260012.pdf

    3.4 MBAdded in Solicitation version 4Posted
    Download
  • S02 Base Offer Breakdown.xlsx

    29 KBAdded in Solicitation version 2Posted
    Download
  • S02-VHA PCRA 2024 1 COR 002.pdf

    498 KBAdded in Solicitation version 2Posted
    Download
  • S02 523A5-18-371-Regulated Building Material Survey Report.pdf

    5.5 MBAdded in Solicitation version 2Posted
    Download
  • S02 523A5-18-371-Drawings.pdf

    15 MBAdded in Solicitation version 2Posted
    Download
  • S02 523A5-18-371 Specifications.pdf

    12 MBAdded in Solicitation version 2Posted
    Download
  • S02 revised Attachment 1 Single Source Justification.doc

    63 KBAdded in Solicitation version 2Posted
    Download
  • S02 523A5-18-371 SOW.docx

    31 KBAdded in Solicitation version 2Posted
    Download
  • 36C24126Q0250.docx

    49 KBAdded in Solicitation version 2Posted
    Download
  • 36C24126Q0250_NOTICE OF TASK ORDER.docx

    23 KBAdded in Presolicitation version 4Posted
    Download

Lifecycle

  1. 7
    Version 7PresolicitationArchived

    Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

    Notice 2e176cde4e414e5b9ae785854bbc1cf1 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Type changed from Presolicitation to Solicitation

    Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

    Notice 76637f76deb54f41a18329b0ad1bd4be on SAM.gov

  3. 3
    Version 3SolicitationArchived

    Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

    Notice afe4064183524d78ad9a4a1afd7fb201 on SAM.gov

  4. 4
    Version 4SolicitationArchived

    Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

    Notice 159f37bcb7bf4c9b9541c1571d27b653 on SAM.gov

  5. 5
    Version 5SolicitationArchived

    Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

    Notice caca4dcd5f2846499b47e5964b44d2aa on SAM.gov

  6. 9
    Version 9SolicitationArchivedCurrent

    Z2DA--523A5-18-371 Building 4 Elevator Replacement (Brockton)

    Notice 21dd481362824e8ca29ea8a25bda2840 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
82%
AwardedOpen
82%
AwardedOpen
657-27-103JB, FCA Replace Building 51 Roof This is a Sources Sought Notice to determine the availability of service disabled veteran owned small business (SDVOSB) firms for a possible small business category type set-aside for Construction Services project: This is a Sources Sought Notice that is issued for information and planning purposes only and is not to be construed as a commitment by the government, implied or otherwise to issue a solicitation or ultimately award a contract. An award will not be made on information received in response to this notice. This notice is not a Request for Proposal (RFP); it is a market research tool being utilized to determine the availability of sources prior to issuing a Best Value type RFP. PROJECT DESCRIPTION AND SCOPE 1. This contract is for CONSTRUCTION services for the work required to replace the existing roof and associated components on Building 51 at the St. Louis Medical Center Jefferson Barracks. 2. Description: Construction services: Furnish complete construction services to replace all designated Building 51 roofs, including projections, entrance roofs, and connecting portions. The preliminary net roof area is approximately 56,000 square feet, subject to field verification. Provide a watertight thermoplastic polyolefin (TPO) roofing system in accordance with the VA-prepared drawings and specifications. Contractor shall submit shop drawings, product data, and installation details for all proposed materials, equipment, and systems to be installed or replaced under this contract for VA review prior to commencing the associated work. Submittals shall include applicable manufacturer's specifications and required engineering certifications. Schedule, phasing, and occupied operations: Complete construction and closeout within 222 calendar days after the Notice to Proceed issue date. Building 51 remains occupied and operational 24 hours per day, seven days per week. Work hours are from 7:00 a.m. to 4:30 p.m., local time. Submit a contractor-developed phasing plan for the Contracting Officer's Representative (COR) to review before roofing. Complete both highest penthouse roof platforms first on the original building and the highest roof section first on the addition; either building portion may be started first. Maintain safe access, utilities, and required infection-control and HVAC-intake protection. Provide construction fall protection and keep the building watertight; coordinate service interruptions with the VA. Investigation and Roofing Requirements: a. Hazardous Materials: While neither Asbestos Containing Material nor Lead is expected to be encountered within the scope of this project, it will be the responsibility of the contractor to hire an independent 3rd party VPIH to complete the related work if they are to encounter a material that they deem suspicious. b. Demolition limit: At the original building (Zones 1-7, 13, and 14), remove the existing roofing assembly through the base sheet to the top of the Zonolite lightweight-concrete topping; retain the topping and underlying structural concrete deck. At the addition (Zones 8-12 and 15), remove the existing roofing assembly, including insulation and intervening layers, to the top of the metal roof deck; retain the deck and supporting structure. Clean and inspect retained surfaces, and repair deterioration within specified repair limits. Report differing construction or deterioration beyond those limits to the COR before proceeding with affected work. c. New roof and mechanical securement: Install mechanically fastened rigid insulation, adhered cover board, and fully adhered 70-mil TPO roofing membrane with continuous hot-airwelded seams. Contractor shall verify that the proposed fastening system is compatible with Building 51's existing roof construction. d. Parapets, penetrations, and retained metal: Extend new roofing up parapets to the existing flashing. Flash and seal, with the correct system specific boots, all roof penetrations with compatible membrane extending at least 8 inches above the finished roof, or higher where required by applicable VA criteria and manufacturer/warranty requirements. Retain metal flashings, flanges, and coping unless scheduled for replacement, and replace roofing beneath retained metal. Specific Replacement and Repairs: e. Associated roof work: Retain rooftop HVAC units in place and replace roofing beneath elevated units and frames and around curbs. Replace old or deteriorated wooden rooftop support blocks with load-rated black rubber blocks compatible with the roofing; retain serviceable recently replaced blocks. Replace roof-drain covers/strainers and recondition retained drains with watertight connections. Reflash existing scuppers and provide new scuppers only where detailed; retain gutters and downspouts unless otherwise indicated. Correct approximately 250 square feet of depressed roof on the original building's middle section north of the penthouse to provide positive drainage. Replace expansion-joint weatherproofing/cover material at two original-building sections, approximately 40 linear feet each. Temporarily remove and reinstall the existing lightning-protection system in its original locations and configuration with new clips securing it; complete specified testing and certification. Repair approximately 150 linear feet of the existing movable stanchion-andrope warning-line barrier. Replace the penthouse roof-access ladder to meet applicable VA safety requirements and OSHA criteria. Install 3-foot by 3-foot walking pads with 8-inch clear gaps along approximately 600 linear feet of total walkway route, including gaps. Provide positive drainage to roof drains and scuppers throughout all reroofed areas. Standing water shall not remain more than 48 hours after rainfall ends under conditions conducive to drying. Correct low spots and other drainage deficiencies that prevent compliance before final acceptance. f. Skylights: Replace four skylights: two approximately 85 square feet each and two approximately 40 square feet each. Field-verify openings and provide complete watertight installations. Before fabrication, submit contractor shop drawings and supporting structural calculations signed and sealed by a licensed structural engineer responsible for their design/review. g. Submittals, record drawings, and closeout: Provide required construction submittals and complete specified testing, inspections, and closeout. Submit a clean, coordinated as-built record drawing set in searchable PDF and editable CAD showing actual installed conditions and accepted changes; redline markups alone are not acceptable. Provide a 20-year nodollar-limit (NDL) warranty and maintenance information, complete cleanup and restoration, and comply with contract records-management, privacy, and security requirements. In accordance with VAAR 836.204, the estimated magnitude of the resulting construction price range is estimated to be between $2,000,000.00 and $5,000,000.00. The North American Industrial Classification System (NAICS) code is 236220, General Construction, small business size standard of $45 Million in average annual receipts for the preceding three years. Interested firms must be registered in https:www.SAM.gov with this NAICS code and qualified as a service disabled veteran owned small business under this NAICS code. Qualified service-disabled veteran owned small businesses are encouraged to respond and required to be registered with the SBA at https://search.certifications.sba.gov/ on or before the response date. The intent of this notice is to identify potential Small Business firms capable of performing these services. The Government will use the information obtained from this sources sought announcement to make a set-aside determination including further restriction under a socio-economic status, firms must identify their socio-economic status for NAICS code 236220, General Construction. The appropriate North American Industry Classification System (NAICS) code for this acquisition is 236220 with the applicable business size of $45 million. If interested in this opportunity, please provide via email a Capability Statement: The Capability Statement is designed to inform the Department of Veteran Affairs, of any prospective construction contractors' project execution capabilities. The submission is limited to 10 single sided pages which shall include the following information: 1) Offeror's name, address, point of contact, phone number, e-mail address, and EIN number; 2) Offeror's interest in bidding on the solicitation when it is issued; 3) Offeror's capability to perform a contract of this magnitude and complexity and comparable work performed within the past 5 years - brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) - provide at least 3 examples; 4) Offeror's CVE certification as a Veteran owned business; 5) Please provide Socio-economic status for NAICS code 236220, General Construction and provide percentage of self-performed labor your company can perform for this type of project; 6) Offeror's Joint Venture information if applicable - existing and potential; 7) Offeror's Bonding Capability in the form of a letter from Surety providing bonding level per contract and aggregate. The Response Due Date for this Sources Sought Notice is November 9. 2026 at 10:00 am Central Time. Respondents will not be notified of the results of analysis. Submit your responses to Jennifer.Hill@va.gov. PLEASE REFERENCE "SOURCES SOUGHT: 36C25527Q0044 Project 657-27-103JB, FCA Replace Building 51 Roof " IN THE SUBJECT LINE and first page of the response. The point of contact for submission of Capabilities Statement and questions is: Jennifer Hill Contracting Officer Email: jennifer.hill@va.gov NCO 15 Contracting Office Leavenworth, Kansas 66048 No basis for claim against the Government shall arise as a result of a response to this sources sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. There is no guarantee, expressed or implicit, that market research for this acquisition will result in a particular set-aside, or any other guarantee of award or acquisition strategy. Respondents will not be contacted regarding their submission or information gathered as a result of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://sam.gov/. The Contract Opportunities website is the only official site to obtain these documents.
82%
Market Research11/09/2026
81%
Combined Synopsis09/30/2026
Successful SDVOSB offeror for solicitation number 36C25526R0127 is: ADBC-FSC JOINT VENTURE LLC 1806 SUMMIT AVENUE, SUITE 300 RICHMOND, VA 23230Â On September 15, 2026, Line Item 1 was awarded under contract number 36C25526C0076 in the amount of $6,681,370.00.
79%
AwardedOpen

Additional Details

Solicitation Number

36C24126Q0250

Archive Date

Jul 30, 2026

Office Address

TOGUS, ME, 04330