Urgent Chiller Plant PRV Valve 2 Repair Samuel S. Stratton (Albany) VAMC
Archived on October 3, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 10:00 AM EDT
- Posted
- September 11, 2026
- Notice type
- Presolicitation
- Set-aside
- No Set aside used
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242)
- Place of performance
- Albany, New York, 12208
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24226Q0942
- Notice ID
- 9aa8c0251a52433ca0cfbf7a9d3e59b7
Description
The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office (NCO 2), Buffalo, New York intends to solicit quotes from contractors to provide, Urgent Chiller Plant PRV Replacement at the Samuel S. Stratton (Albany) VA Medical Center, 113 Holland Ave., Albany, NY 122084 under a single-award firm-fixed price contract. This procurement will be solicited in accordance with FAR Part 12 Acquisition of Commercial Products and Commercial Services, specifically FAR 12.201-1(c)(2).
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C24226Q0942_1.docx
24 KBAdded in Presolicitation version 3Posted
Lifecycle
- 3Version 3PresolicitationArchivedCurrent
Urgent Chiller Plant PRV Valve 2 Repair Samuel S. Stratton (Albany) VAMC
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The Rome Community Based Outpatient Clinic (CBOC) located at 125 Brookley Road, Rome, NY 13441 has a need to demolish two (2) existing boiler exhaust stacks and one (1) generator steam relief stack and demolish the concrete / masonry chimney structure and seal the existing roof and construct and install two (2) new steel boiler exhaust stacks, the steel support structure, and one (1) steel generator exhaust pipe. | - | Solicitation | 12/02/2026 |
The VA Western New York Healthcare System (VAWNYHS) facilities located at 3495 Bailey Ave, Buffalo NY 14223 and 222 Richmond Ave, Batavia NY 14020 are seeking a firm fixed price contract for a base year plus four (4) option year periods for annual scheduled backflow prevention testing to also include emergency repair. | - | Market Research | 11/06/2026 |
36C24227Q0042 Mod 2 Answers to questions submitted: Q1: What is the observed historical peak steam load of the facility? A1: 120,000 lb./hr. Q2: Will the Montrose VAMC waive the requirements of the VHA Safety Device and Testing Manual? A2: No. Q3: Air permits for emissions are the responsibility of the entity operating/generating the emission, not the owner of the equipment. Please clarify. A3: VA only, not the vendor. Q4: Will the VA change the 9PPM NOx requirement to 30 PPM? A4: No. Q5: Please clarify the size of the Boiler. A5: 800 HP Q6: Will fuel for the rental boiler be furnished by the Government of the Contractor? A6: Government Q7: Confirm intended placement and connection routing if boiler placement is on the south end but connections are at the north end? A7: East side of the plant (end near Boiler 1 near Building 24 hazmat storage area) Q8: What is the required installation and ready for service date? A8: Installation 11/1/2026. Ready for service 12/1/2026. Q9. Is a rental unit rated at about 30ppm NOx on natural gas acceptable for the temporary heating period, given that it is a temporary rental operating under the facility s existing permit? A9. Yes Q10. If 9 ppm NOx is mandatory, will the Government accept a unit fitted with flue gas recirculation (FGR) or selective catalytic reduction (SCR) to meet it, and will any additional time be allowed for delivery? A10. The most important factor is that the vendor make the delivery date, so the 9-ppm cis is not a deal breaker. Q11. The requirement lists a 95 PSIG operating pressure but also references 35,000 lb./hr. at 212° F and a 15 PSIG code. What operating pressure should the rental boiler be size for? A11. 95 PSI is sufficient. Q12. Can a portable day tank with a capacity of 10,000 gallons be placed next to the portable boiler in lieu of installing a return line several hundred feet across to the opposite end of the boiler plant? A12. No. ** Please acknowledge all amendments with your response** | - | Combined Synopsis | 10/21/2026 |
This pre-solicitation notice is to inform potential offerors that the Rome Community Based Outpatient Center (CBOC) in Rome, NY will be posting a solicitation (36C24227R0008) on or about October 30th, 2026, to provide all labor, materials, tools, equipment, and supervision necessary to complete the Replace Boiler Stack Rome CBOC project (528A7-18-707). This project is necessary to demolish two (2) existing boiler exhaust stacks and one (1) generator steam relief stack, the concrete / masonry chimney structure and seal the existing roof. The construction and installation of two (2) new steel boiler exhaust stacks, the steel support structure, and one (1) steel generator exhaust pipe at the Rome CBOC, 125 Brookley Road, Rome, NY 13441. It has been determined that there are qualified firms that can perform under NAICS Code 238220, "Plumbing, Heating, and Air Conditioning Contractors with a size standard of $19M. This procurement is 100% set-aside for small businesses. The estimated construction value of this project is between $500,000 and $1,000,000. Information regarding the scheduled site visit will be stated in the Solicitation. Bid bonding will be required to respond to this RFP once released. OBTAINING SOLICITATION MATERIAL Solicitation materials consisting of the Information for Proposal Details, Specifications, Drawings and Contract Forms will be available on http://www.sam.gov in electronic format only. These should be available on or about October 30th, 2026. An Offeror's mailing list, list of interested parties and/or list of attendees at site visits WILL NOT be prepared nor distributed by the Contract Specialist. SOLICITATION AMENDMENTS: Amendments to the solicitation will be posted at http://www.sam.gov. Paper copies of the amendments will NOT be individually mailed. No other notification of amendments will be provided. Offerors are reminded that they are responsible for obtaining and acknowledging all amendments to this solicitation and attaching to their proposal. All proposals and correspondence will be by email only to the Contract Specialist: Ryan.Seburn@va.gov. | - | Pre-Solicitation | 10/28/2026 |
Award Notice from solicitation 36C24226Q0816. | - | Awarded | Open |
Additional Details
Solicitation Number
36C24226Q0942
Archive Date
Oct 3, 2026
Office Address
ALBANY, NY, 12208