Notice ID: 61be77e6a6224ce7a6005138a118c5b0Special Notice
6550--Intent to Sole Source Streck Flow Cytometry Controls
Archived on September 17, 2021. Full description on SAM.gov.
Overview
- Posted
- September 2, 2021
- Notice type
- Special Notice
- NAICS
- 339112: Surgical and Medical Instrument Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246)
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C24621Q1371
- Notice ID
- 61be77e6a6224ce7a6005138a118c5b0
Description
NOTICE OF INTENT TO SOLE SOURCE: The Department of Veterans Affairs Network Contracting Office 6, 100 Emancipation Drive, Hampton, VA 23667, intends to award a sole source agreement/contract to Streck Labs Inc. for Quality Control of Flow Cytometry for Richmond VAMC. Reagents and supplies for use with existing instrumentation. The procurement of consumables for the quality control of antibodies used in the diagnosis of leukemia and lymphoma. Control material should provide the most diverse amount of control reactivity per product. Also, rare occurrence antibody controls should be available. Streck, Inc. offers the most comprehensive product line to satisfy all quality control needs and provides interlaboratory QC evaluations necessary to meet regulatory standards for which the Government intends to solicit from only one source. The North American Industry Classification System (NAICS) for this requirement is 339112 with a small business size standard of 1000 employees. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTATIONS. Responsible sources may identify their interest and capability to meet this requirement by submitting such information by 11:00 A.M., EST. on 07 September 2021. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. If your firm is a Service-Disabled Veteran Owned or Veteran Owned Small Business, you must be CERTIFIED in VetBiz (see internet site: http://vip.vetbiz.gov). An authorized dealer/distributor letter must be submitted with supporting evidence. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will be used to determine acquisition strategy. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to ellen.fisher1@va.gov. Telephone inquiries will not be accepted.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C24621Q1371- Special NoticeCurrentSep 2, 2021
6550--Intent to Sole Source Streck Flow Cytometry Controls
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
JUSTIFICATION POSTING | 72% | Sole Source / J&A | Open |
INTENT TO SOLE SOURCE: Â The Department of Veterans Affairs Network Contracting Office (NCO) 6, intends to award a contract on a sole source basis to MEDTRONIC, INC to acquire MIDAS MR8 ELEC MOTOR STEALTH-MIDAS systems located at the Richmond VAMC. Supply to include KIT MIDAS MR8 ELEC MOTOR STEALTH-MIDAS, MOTOR MR8 ELECTRIC NAVIGATED S8, CASE MR8 INSTRUMENT 3/4 DIN NAVIGATED, CASE MR8 STERILIZATION 3/4 DIN, ACCY PA305 LEGEND SMALL CLEANING BRUSH, ACCY PA315 LEGEND MEDIUM CLENING BRUSH, ACCY PA325 LEGEND LARGE CLEANING BRUSH, ACCY PA130 LEGEND MOTOR WRENCH, ATT MR8 14CM VARIABLE STRAIGHT 3.2MM, and StealthStation navigation compatibility. The estimated period of performance is expected to be 23 NOV 2026 through 22 MAR 2026. MEDTRONIC, INC has been determined to be the only supplier of these supplies with StealthStation navigation compatibility. Any company that can legally provide the above services should send a capability statement including the following: Firm name Point of contact Title Address Telephone number to stephen.nassan@va.gov no later than 12:00 pm, EST, on 11/19/2026. As a Sole Source purchase, quotes are not being requested. | 59% | Special Notice | 11/19/2026 |
59% | Awarded | Open | |
SPECIAL NOTICE NOTICE OF INTENT TO SOLE-SOURCE Impella CP Catheter Kit 36C25027Q0118 The Department of Veterans Affairs, Richard L Roudebush VAMC, NCO 10 Contracting Activity intends to solicit to negotiate a sole source Purchase Order under Simplified Acquisition Procedures and the authority of FAR 6.103-1, soliciting from a single source for the following items listed below. NAICS code for this is 339112, Surgical and Medical Instrument Manufacturing. The SDVOSB vendor will be Geo-Med, LLC, located at 1525 International PKWY STE 3071, Lake Mary, Florida 32746. Description of requirements: The Cincinnati VAMC is requesting the purchase of 3 (three), Impella CP with Smart Assist Heart Pump & Companion Sheath Bundles. These are the only items that will meet the current requirement for the Interventional cardiologists that will be providing this critical care to veterans. Line Item Description Quantity Unit of Measure 0001 Impella CP with Smart Assist Heart Pump & Companion Sheath Bundle Includes: (1) Purge Cassette (1) 14Fr Introducer Sheath, 13cm (1) 14Fr Introducer Sheath, 25cm (1) Placement Guidewire, .035'' x 150cm (1) Placement Guidewire, .018'' x 260cm (1) 7Fr Low Profile Companion Sheath Johnson & Johnson Abiomed (Part Number 4000021) 3 EA Delivery will be to: Department of Veterans Affairs Cincinnati VA Medical Center 3200 Vine St. Cincinnati OH 45220 A firm fixed price purchase order is anticipated and shall be awarded. It is the Government's belief that only the proposed candidate possesses the required capabilities to successfully meet this requirement. It is the Government's intention to solicit and negotiate with only this source. This notice of intent is not a request for competitive proposals. It is not a solicitation or request for offers. No solicitation package is available. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Responses must be received no later than 5:00 pm on Friday, November 20, 2026. Only email responses will be accepted. LouAnn Gilliland Contracting Officer louann.gilliland@va.gov | 54% | Special Notice | 11/20/2026 |
DESCRIPTION The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Microscopes, Light, Operating, Hand/Plastic Surgery product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award. The Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Enterprise Procurement Office (EPO) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The EPO in conjunction with VHA is seeking a qualified source to provide Leica Microsystems M530 OHX Microscopes, Light, Operating, Hand/Plastic Surgery brand name or equal Microscopes, Light, Operating, Hand/Plastic Surgery on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Microscopes, Light, Operating, Hand/Plastic Surgery to VA medical centers and facilities throughout the United States and its territories. The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission. Submissions for this source sought shall be submitted by email no later than November 30th, 2026, at 10:00 am EST to all the following: Jalima.Jones@va.gov Sara.Vickroy@va.gov This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 SCOPE Microscopes, Light, Operating Hand/Plastic Surgery - An operating light microscope designed for hand, plastic, and reconstructive surgery. The microscope provides illuminated, magnified stereoscopic visualization of delicate anatomical structures during microsurgical procedures, including repair of small blood vessels, nerves, tendons, and soft tissue. It is intended to support precise surgical visualization and ergonomic positioning during hand surgery, reconstructive procedures, peripheral nerve repair, microvascular anastomosis, replantation, and related plastic-surgery procedures. The following Contract Line-Items Number (CLIN) are being considered: CLIN Manufacturer Part Number Description 0001 Leica Microsystem 10449213 ARveo 8x Stand for M530 0002 Leica Microsystem 10448704 M530 Optics Carrier for ULT 530 0003 Leica Microsystem 10446058 Protective glass M50xx, M620 0004 Leica Microsystem 10448668 Magnification Multiplier 1.4x 0005 Leica Microsystem 10740017 Dust Cover 0006 Leica Microsystem 10446797 Binocular tube var. 30-150°T,Typ II L 0007 Leica Microsystem 10448028 Eyepiece f. spect. W's 10x/21B, type II 0008 Leica Microsystem 10448597 Stereo attachment for second observer 0009 Leica Microsystem 10446797 Binocular tube var. 30-150°T,Typ II L 0010 Leica Microsystem 10448028 Eyepiece f. spect. W's 10x/21B, type II 0011 Leica Microsystem 10448088 Binoc.tube var.0-180°t,type II 0012 Leica Microsystem 10448028 Eyepiece f. spect. W's 10x/21B, type II 0013 Leica Microsystem 10445664 Power cable, 5m, North America 0014 Leica Microsystem 10449091 Stand Monitor Kit for ARveo 8 0015 Leica Microsystem 10448872 Wireless Footswitch 12-functions Type B 0016 Leica Microsystem 10448245 Mouth switch 0017 Leica Microsystem 10448795 Leica FL560 for M530 0018 Leica Microsystem 10449201 FL560 Activation for ARveo 8 0019 Leica Microsystem 10747162 Test pattern FL560 0020 Leica Microsystem 10449156 GLOW800 0021 Leica Microsystem 10449012 CART Set 55" 0022 Leica Microsystem 10449164 MyVeo Headset 0023 Leica Microsystem 10449167 MyVeo 0024 Leica Microsystem 10748932 Hub mounting set for ARveo 8x 0025 Leica Microsystem 10449097 3D License The Department of Veterans Affairs (VA) is seeking vendors who can provide Leica Microsystems M530 OHX Microscopes, Light, Operating, Hand/Plastic Surgery brand name or equal Microscopes, Light, Operating, Hand/Plastic Surgery as listed above or equal commodities which meet all the following salient characteristics (SCs): SC # SALIENT CHARACTERISTICS Applicable CLIN METHOD OF EVALUATION SC 1 The system shall be a mobile, floor-standing surgical microscope providing binocular stereoscopic visualization for the surgical procedures 0001 - 0025 Literature Review SC 2 The system shall provide motorized, continuously variable magnification adjustable through sterile operator controls. 0001 - 0025 Literature Review SC 3 The system shall provide adjustable surgical-field illumination and illumination of deep, narrow operative cavities 0001 - 0025 Literature Review SC 4 The system shall provide operator-controlled microscope repositioning, selectable brake release, and motorized XY positioning or tilt adjustment 0001 - 0025 Literature Review SC 5 The system shall provide adjustable primary-surgeon binocular viewing and an assistant viewing configuration 0001 - 0025 Literature Review SC 6 When required, the delivered system shall include fluorescence visualization 0001 - 0025 Literature Review For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendors are requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company CAGE Code/ SAM UIE Business Size Manufacturer or Distributor If the distributor provides full name, business size and address of manufacturer. Country of Origin designation for all products Ability to provide uninterrupted supply of products on a national scale. Technical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Authorized Distributor Letter Certified by OEM with a current date. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. | 54% | Market Research | 11/30/2026 |
Additional Details
Solicitation Number
36C24621Q1371
Archive Date
Sep 17, 2021
Office Address
HAMPTON, VA, 23667