GovChime
Notice ID: 7ac7a17661de4dc8a6ad8c617554bc8cSolicitation

Amendment 0001 Radiation Safety Officer for the Eastern Oklahoma VA Health Care System

Responses closed . Full description on SAM.gov.

Overview

Response deadline
4:00 PM MST
Posted
October 21, 2026
Notice type
Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
541380: Testing Laboratories and Services
Agency
Department of Veterans Affairs

Notice details

Office
NETWORK CONTRACT OFFICE 19 (36C259)
Place of performance
Muskogee, Oklahoma, 74401
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25927R0005
Notice ID
7ac7a17661de4dc8a6ad8c617554bc8c

Description

The Contractor shall furnish key personnel to provide services necessary to perform onsite Radiation Safety Officer (RSO) duties for the Eastern Oklahoma Veteran Affairs Health Care System (EOVAHCS). The RSO will oversee the daily operations for the facility, performing all duties associated with that role. The RSO position is a director-appointed position and answers directly to the Chief of Staff (COS) or designee. The RSO is responsible for all radiation-related issues that are associated with the Eastern Oklahoma Veteran Affairs Health Care System (EOVAHCS).  The RSO will establish and implement radiation safety procedures commensurate with the use of fluoroscopy and reviewing them periodically to ensure their conformity with Federal Radiation Safety Regulations VHA directive 1105.02. Ensuring regulatory standards for radiation safety and medical physics practices are followed throughout the facility in accordance with: VHA-Directive-1105.02-Nuclear-Medicine-and-Radiation-Safety-Services.aspx

D 1105 Management of Radioactive Materials for SharePoint_20251126.pdf

VHA 1129 Directive.pdf and

10 CFR 35.2 (see RSO definition: experienced RSO) or 10 CFR 35.50 and 35.59 (for a new RSO)

NUREG-1556, Vol. 9, Rev. 35 CFR § 731.106

https://www.ecfr.gov/current/title-5/chapter-I/subchapter-B/part-731/subpart-A/section-731.106.

Place of Performance: Services shall be provided onsite at the following Eastern Oklahoma Veteran Affairs (VA) Health Care System (EOVAHCS) locations:

  1. Jack C Montgomery Veteran Affairs Medical Center, located at 1011 Honor Heights Dr.,  Muskogee, OK 74401
  2. Ernest Childers Veteran Affairs Outpatient Clinic, located at 8921 S Mingo Rd Tulsa, OK, 74133
  3. James Mountain Inhofe Veteran Affairs Medical Center, located at 440 S Houston Ave, Tulsa OK, 74127

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (6)

  • 36C25927R0005 0001.docx

    121 KBAdded in Solicitation version 2Posted
    Download
  • D.4 QUALITY ASSURANCE SURVEILLANCE PLAN _QASP.docx

    33 KBAdded in Solicitation version 1Posted
    Download
  • D.1 IMMIGRATION CERTIFICATION.docx

    23 KBAdded in Solicitation version 1Posted
    Download
  • D.2 CONTRACTOR ORGANIZATION CONFLICT OF INTEREST CERTIFICATION.docx

    23 KBAdded in Solicitation version 1Posted
    Download
  • D.3 CONTRACTOR RULES OF BEHAVIOR.docx

    17 KBAdded in Solicitation version 1Posted
    Download
  • S02 36C25927R0005_RELEASED FOR SOLICITATION_13OCT.docx

    254 KBAdded in Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Solicitation

    Radiation Safety Officer for the Eastern Oklahoma VA Health Care System

    Notice d06dd19acd4b4017b884324d3121b73f on SAM.gov

  2. 2
    Version 2SolicitationCurrent

    Amendment 0001 Radiation Safety Officer for the Eastern Oklahoma VA Health Care System

    Notice 7ac7a17661de4dc8a6ad8c617554bc8c on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
FIRE/SMOKE DOORS AND FIRE/SMOKE WALL INSPECTION OKLAHOMA CITY VA MEDICAL CENTER OKLAHOMA CITY, OK
-Pre-Solicitation08/24/2026
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.
-Combined Synopsis11/12/2026
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov
-Pre-Solicitation12/10/2026
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov
-Pre-Solicitation12/10/2026
Contractor shall provide all labor, supplies, equipment, and supervision necessary to provide Wastewater Effluent Laboratory Analysis Services to the Aleda E. Lutz VA Medical Center described herein. Wastewater Effluent Laboratory Analysis Services include, but are not limited to sample preparation, collection, and storage; transportation of wastewater effluent samples to a laboratory, performance of analytical testing; reporting of analytical test results; and consultative services.
-Solicitation11/06/2026

Additional Details

Solicitation Number

36C25927R0005

Archive Date

Nov 18, 2026

Office Address

Greenwood Village, CO, 80111