Notice ID: 8aa4d25092e84b44b403a373fd2bce36Award NoticeAwarded
Y1DA--FY 2024 requirement - CON 663-CSI-020 Renovate Building 100 2nd Floor, CT Replacement
Awarded on September 29, 2024. Full description on SAM.gov.
Awarded tounder 36C26024C0063 (source: SAM.gov award notice)• $2.2M
Overview
- Posted
- September 30, 2024
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 236220: Commercial and Institutional Building Construction
- Agency
- Department of Veterans Affairs
Notice details
- Place of performance
- VA Puget Sound Healthcare System 1660 S Columbian Way, Seattle, 98108
- Last updated
- Dec 4, 2025
- Award date
- Sep 29, 2024
- Award amount (SAM.gov award notice)
- $2.2M
Identifiers
- Solicitation number
- 36C26024R0098
- Notice ID
- 8aa4d25092e84b44b403a373fd2bce36
- Award number (PIID)
- 36C26024C0063
Description
VA Puget Sound Health Care System (HCS) Seattle, WA Solicitation Number: 36C26024Q0591 Project Number: 633-CSI-020 Description: Renovate Building 100, 2nd Floor for CT Replacement 663-CSI-020 The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20 anticipates soliciting proposals and subsequently awarding a single, Firm-Fixed-Price Construction Contract to Renovate Building 100, 2nd Floor for CT Replacement at the Seattle VA Medical Center, 1660 S. Columbian Way, Seattle, Washington, 98108. DESCRIPTION: The Veterans Health Administration (VHA) Puget Sound Health Care System (HCS) Seattle, WA, is remodeling approximately 1500 square feet of existing space to replace one Computed Tomography (CT) scanner and add an additional CT with VA specified equipment. Renovate approximately 1500 square feet of interior space based on the requirements of the VA imaging design guide. The new layout will include two CT suites, a shared control room, and a patient prep area. Each CT suite will provide one CT machine and host the supporting equipment for operation. All necessary utilities are in the building and must be extended and connected from surrounding areas. Renovation of the space in B100 will include removal and installation of walls, floors, and ceiling finishes. New casework for CT rooms and control rooms will be installed based on the drawings and specifications. Requirements from the equipment manufacturer will be followed for work necessary for the manufacturer to complete installation of GE Revolution Apex CT scanners. Work includes the following but is not limited to: replacement of floor and ceiling finishes, ceiling systems, mechanical (HVAC), medical gas, lead shielding, asbestos abatement, electrical, telecommunications, nurse call, security, fire alarm, and fire protection sprinkler work. New finishes should match existing finishes and color schemes in the hallway and supporting spaces, unless otherwise noted. Construction in interstitial spaces will include the rework of HVAC system air distribution and other associated Mechanical, Electrical and Plumbing (MEP) work along with structural provisioning for supporting the new CT equipment. This project will occur in two phases. Phase 1: Include all project demolition and necessary work associated with room S2.276 and all supporting space (i.e. the Control Room and Patient Prep Room) in 180 days. The first additional CT and all supporting spaces must be constructed, installed, and operational prior to starting Phase II. This room is being designed to support the operational and functional equipment, the GE Revolution CT APEX EL Digital (Revolution Apex CT Typical Final Drawing, Revolution Apex CT Preinstallation Manual). The current CT in S2.280 shall remain operational during Phase 1 for patient care. GE will be responsible for moving the Revolution Apex CT from Building 100 loading dock to completed room S2.276. Phase 2: Include all necessary work associated with installing the replacement second CT machine and associated equipment in room S2-280 in 105 days. This room is being designed to support the operational and functional equipment, the GE Revolution CT APEX EL Digital (Revolution Apex CT Typical Final Drawing, Revolution Apex CT Preinstallation Manual). Refer to the drawings and specifications for details on the extent of construction. GE will remove CT system currently installed in room S2-280. GE will be responsible for moving the Revolution Apex CT from Building 100 loading dock to completed room S2.280. The Product Service Code (PSC) for this procurement is Y1DA - Construction of Hospitals and Infirmaries. The North American Industry Classification System (NAICS) code for this procurement 236220 - Commercial and Institutional Building Construction, and the business size standard is $45.0 Million. Per VAAR 836.204 The magnitude of construction for this project is between $1,000,000 and $2,000,000. As noted, this procurement is 100% Set-Aside for Service-Disabled Veteran Owned Small Business (SDVOSB) concerns. Offerors must be certified as SDVOSBs by the U.S. Small Business Administration (SBA) and visible in the Veteran Small Business Certification (VetCert) database (https://veterans.certify.sba.gov/) at the time of submission, written response submission, and award. Only verified SDVOSB firms are eligible to submit an offer or receive an award of a VA contract that is set-aside for SDVOSB in accordance with VAAR Part 819. A non-verified vendor that submits a bid or proposal will be rejected as non-responsive. Offers received from concerns that are not Service-Disabled Veteran-Owned Small Business (SDVOSB) concerns shall not be considered. This solicitation notice is a request for proposals and are due on August 22, 2024 at 2:00pm PST. The point of contact for this solicitation is Robert.Capers2@va.gov. The Contracting Officer is Ty.Draszt@va.gov. See all attachments for full solicitation, specifications, drawings and supporting documents.
Award Overview
Award Number
36C26024C0063
Award Amount (SAM.gov award notice)
$2.2M
Award Date
Sep 29, 2024
Awardee
Awardee UEI
NWJ1Z3M5EAE5
Awardee CAGE Code
5T9Q4
Original Solicitation
Notice ID: 8aa4d25092e84b44b403a373fd2bce36
Posted Date: Sep 30, 2024
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $5.2MSigned Oct 28, 2026
- $3.7MSigned Oct 27, 2026
- $18.6MSigned Oct 19, 2026
- $2.6MSigned Oct 13, 2026
- $4.2MSigned Oct 6, 2026
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C26024R0098- Combined Synopsis
- Awarded
This opportunity has been awarded.
- 4×Combined SynopsisJul 22, 2024
Y1DA-- CON 663-CSI-020 Renovate Building 100 2nd Floor, CT Replacement
- AwardedCurrentSep 30, 2024
Y1DA--FY 2024 requirement - CON 663-CSI-020 Renovate Building 100 2nd Floor, CT Replacement
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Posting Amendment 0006 to provide official RFI Responses, updated Solicitation Documents, extend the Proposal Due Date, and other official information. | - | Solicitation | 11/25/2026 |
Amendment 0005 to extend the proposals due date and other official information. | - | Solicitation | 11/18/2026 |
531-25-102. Posting Amendment 0004 to extend the due date. | - | Solicitation | 11/06/2026 |
653-27-106 Remodel Bathroom Building 1 A Wing Floors 1 and 2 | - | Pre-Solicitation | Open |
Amendment 0003 to publish Site Visit Agenda and Sign-In Sheet | - | Solicitation | 10/30/2026 |
Additional Details
Solicitation Number
36C26024R0098
Archive Date
Nov 29, 2024
Office Address
VANCOUVER, WA, 98661