GovChime
Notice ID: ad12fc986bdb43859919693feb05d452Sources SoughtArchived

Bio Safey Cabinets

Archived on May 16, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
May 12, 2026
Notice type
Sources Sought
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of Health and Human ServicesFOOD AND DRUG ADMINISTRATION

Notice details

Office
FDA OFFICE OF ACQ GRANT SVCS
Place of performance
Laurel, Maryland, 20708
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
SSN_CVM-2026-134067
Notice ID
ad12fc986bdb43859919693feb05d452

Description

We expect to acquire seven new BSCs according to our specifications. The Contractor shall provide seven (7) biosafety cabinets consisting of:

•         One (1) 6-foot wide unit

•         Six (6) 4-foot wide units

All BSCs are expected to meet certification standards (NSF/ANSI 49) upon delivery.

Deliverables

The following are the requirements that should be met at the minimum:

•         Class II: Protects personnel, environment, and product (samples). The most common type, offering sterile conditions, ideal for BSL-1 through BSL-3.

•         Units shall be available in unit widths of 6 ft (one unit) and 4 ft (six units)

•         Units must meet the performance requirements of NSF/ANSI 49.

•         Units shall have supply HEPA filters 99.99% efficient at a particle size of 0.3 micron by DOP test and shall be of full cabinet work zone width and depth.

•         Units shall have exhaust HEPA filters 99.99% efficient at a particle size of 0.3 microns by DOP test

•         Units shall be constructed from 16 or 18 gauge Type 304 stainless steel, forming a monolithic, sealed structure.

•         Units shall possess a height adjustable base stand such that workspace height can be adjusted from at least 30 to 36 inches.

•         Units’ power shall be supplied with a minimum 12-foot (2.5m) grounded electrical cable. Electrical supply should be 115 VAC, 60 Hz.

•         Units shall be easily transportable through a 40 inch (1016 mm) wide, 83 in (2108 mm) tall door without disassembly.

•         Units shall come standard with two outlets with drip proof covers; one gas valve/service coupling on right side wall; one service coupling on right side wall; two service couplings on left side wall.

•         Units shall be capable of front filter removal without disassembly of the control panel and sliding window tracks/hardware.

•         Units shall feature a sliding viewing window that operates smoothly from full closure to full opening at 20 inches.

•         Units shall have a working access height of 10 inches.

•         Units shall feature a non-metallic armrest/airfoil incorporating an at least 2 inch (51mm) forearm support area.

•         Units shall feature an audible alarm and flashing LED to warn of an unsafe viewscreen position. The units will also signal power loss with visual and audible alarms

•         Units shall include base stand with work surface height between 25 and 35 in

•         Units shall include an ultraviolet (UV) light fixture.

•         Units shall be warranted for parts and labor for at least 60 months from the date of acceptance.

•         Pricing shall include shipping cost.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • SSN.docx

    30 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 1
    Version 1Sources SoughtArchived

    Bio Safey Cabinets

    Notice 3bf70a383e724120bf7cdb16050306bb on SAM.gov

  2. 3
    Version 3Sources SoughtArchivedCurrent

    Bio Safey Cabinets

    Notice ad12fc986bdb43859919693feb05d452 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

SSN_CVM-2026-134067

Archive Date

May 16, 2026

Office Address

Rockville, MD, 20852