GovChime
Notice ID: 971f5e4298434d9d878682f6c5296e67SolicitationArchived

TAFB MACC-BOA | Formal RFP for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

Archived on July 18, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:00 PM CDT
Posted
June 18, 2026
Notice type
Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
238210: Electrical Contractors and Other Wiring Installation Contractors
Agency
Department of WarDepartment of the Air Force

Notice details

Office
AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8137 AFSC PZIOC
Place of performance
S Coffeyville, Oklahoma, 73145
PSC
Z2JZ: REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
FA813726R0038
Notice ID
971f5e4298434d9d878682f6c5296e67

Description

This order proposal request is only available to current MACC-BOA holders.

The work to be performed under the terms of this Order consists of furnishing all materials, labor, plant, tools, transportation, equipment, testing services, quality control, and incidentals required to accomplish the repair/replacement of the main distribution & branch panel boards in building 6002 at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information). This is a construction-only order.

The Contractor shall perform a site investigation to verify existing conditions. If necessary, additional as-built drawings are available from 72 ABW/CE - Engineering Support, located in B400 on Tinker AFB.

The Contractor shall be responsible for identifying the necessary logistical, architectural, and structural work elements required to perform the work as described herein. Assemblies, framework, fixtures, or apparatus not readily identified on the project drawings, specifications, or the Statement of Work (SOW) shall be provided by the Contractor as required for a complete, fully operating, and functioning system or systems ready for use by the Government.

Information such as floor plan layouts and dimensions; structural, mechanical, and electrical data; and location of underground utilities provided by the Government for existing and new construction are based on available as-built documentation, field observation, and equipment selected as design basis by the Government. This information is to be considered approximate and shall be field verified by the Contractor.

This project will not require contractor personnel to perform work and/or operate vehicles on flight lines, runways, taxiways, parking ramps, or in aircraft hangers or maintenance areas. However, all contractor personnel are still required to receive FOD awareness training in accordance with Tinker Air Force Base Instruction (Tinker AFBI) 21-100.

IAW National Institute of Standards and Technology (NIST) Special Publication (SP) 800-171, the requirement does not include CUI residing on or transiting through contractor and/or subcontractor systems.

Site visit attendance is mandatory to be considered eligible for submission of proposal. RSVP email confirmation of intent to attend the site visit to the primary and secondary points of contact with Entry Authorization List (EAL) information by 11:59 PM CST, Friday, May 22nd, 2026. If a Contractor/Subcontractor fails to meet this deadline, the site visit information will not be released to your organization. Order documents not able to be uploaded to SAM.gov will be provided to contractors who RSVP'd their intent to attend the initial site visit.

Attachments include an EAL spreadsheet. Please fill-in all information for individuals who will need/do not currently have Base access. Please ensure all information requested in the EAL is filled out accurately and full names matching state-issued IDs are utilized to assure Security Forces can process the requests for Base Access in a timely manner.  If an individual has Base access, their name is all the information needed. Please try to limit your parties to seven attendees per Contractor.

The site visit is scheduled for June 3rd, 2026 at 10:00 A.M at the project performance site. More specific meeting details will be shared with contractors who have sent an RSVP.

The due date for the RFIs arising from the site visit is currently set for June 8th, 2026 at 5:00 PM CST. RFIs will be answered in a timely manner, and RFI responses will be shared with all site visit attendees.

This notice signifies the release of the formal RFP for Project No. WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002. The due date for proposals is currently July 3rd, 2026 at 5:00 PM CST but is subject to be extended dependent upon RFI responses. Any extensions granted to the proposal due date will be updated to this posting. Please see the attachments for the formal RFP as well as the attachments referenced in the body of the formal RFP. Responses to received RFIs may warrant revisions to associated RFP documents so be sure to monitor this SAM posting for updates.

In lieu of the physical CD, some additional documents have been added to the attachments section including the Project Docs, Facility Standards, and some additional large files. Please contact the primary and secondary points of contact if you experience any difficulty downloading or accessing the documents.

All RFI responses have been received and compiled. Please see the attachments for the RFI responses. Utilize these in continuing to formulate your proposals. If RFI responses prompt a need for an extension to the proposal due date, please communicate that to the primary and secondary points of contact, and any extensions granted will be updated to this posting.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (18)

  • 050751_Compiled Pre-Bid RFIs_Gov Responses.pdf

    175 KBAdded in Solicitation version 7Posted
    Download
  • CTR CD_Project Docs_Att 1.zip

    67 MBAdded in Presolicitation version 4Posted
    Download
  • CTR CD_Project Docs_Att 1.zip

    67 MBAdded in Solicitation version 3Posted
    Download
  • CTR CD_Base Facility Standards_Att 2.zip

    2.1 MBAdded in Presolicitation version 4Posted
    Download
  • CTR CD_Base Facility Standards_Att 2.zip

    2.1 MBAdded in Solicitation version 3Posted
    Download
  • CTR CD_Large Files_Att 3.zip

    214 MBAdded in Presolicitation version 4Posted
    Download
  • CTR CD_Large Files_Att 3.zip

    214 MBAdded in Solicitation version 3Posted
    Download
  • FA813726R0038_Draft.pdf

    649 KBAdded in Presolicitation version 1Posted
    Download
  • FA813726R0038_Formal RFP.pdf

    645 KBAdded in Solicitation version 2Posted
    Download
  • 050751_Section L_Instructions to Offerors.pdf

    827 KBAdded in Presolicitation version 1Posted
    Download
  • 050751_Section L_Instructions to Offerors.pdf

    827 KBAdded in Solicitation version 2Posted
    Download
  • 050751_Section M_Evaluation Factors for Award.pdf

    394 KBAdded in Presolicitation version 1Posted
    Download
  • 050751_Section M_Evaluation Factors for Award.pdf

    394 KBAdded in Solicitation version 2Posted
    Download
  • EAL_CTR to Fill.xlsx

    62 KBAdded in Presolicitation version 1Posted
    Download
  • 050751_Drawings.pdf

    2.0 MBAdded in Solicitation version 2Posted
    Download
  • 050751_Drawings.pdf

    2.0 MBAdded in Presolicitation version 1Posted
    Download
  • 050751_SOW.pdf

    312 KBAdded in Solicitation version 2Posted
    Download
  • 050751_SOW.pdf

    312 KBAdded in Presolicitation version 1Posted
    Download

Lifecycle

  1. 6
    Version 6PresolicitationArchived

    TAFB MACC-BOA | Initial Site Visit for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

    Notice 3e0a2f4970ed4ec8a12c94ea773510e3 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Type changed from Presolicitation to Solicitation

    TAFB MACC-BOA | Formal RFP for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

    Notice f19004c99a95408ea2899e2beced43e3 on SAM.gov

  3. 3
    Version 3SolicitationArchived

    TAFB MACC-BOA | Formal RFP for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

    Notice 10d6af1b44704e429d0f5499e83e6d73 on SAM.gov

  4. 4
    Version 4SolicitationArchived

    TAFB MACC-BOA | Formal RFP for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

    Notice 4d93fcac604f4c869e3f907bb8ebefb3 on SAM.gov

  5. 7
    Version 7SolicitationArchivedCurrent

    TAFB MACC-BOA | Formal RFP for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

    Notice 971f5e4298434d9d878682f6c5296e67 on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationRelated noticeMay 15, 2026

    TAFB MACC-BOA | Initial Site Visit for WWYK050751 - Repair/Replace Main Distribution & Branch Panel Boards, Bldg. 6002

    Notice bcc16d0dc6a54f30be229d2f7f3494d3 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

FA813726R0038

Archive Date

Jul 18, 2026

Office Address

TINKER AFB, OK, 73145-9125