GovChime
Notice ID: 566da056153847aa9877b549f58b75adSolicitationArchived

Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

Archived on August 5, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM EDT
Posted
April 20, 2026
Notice type
Solicitation
NAICS
236220: Commercial and Institutional Building Construction
Agency
Department of Veterans Affairs

Notice details

Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Place of performance
Miami VA Medical Center 1201 NW 16th Street, Miami, Florida, 33125
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24826R0028
Notice ID
566da056153847aa9877b549f58b75ad

Description

The contractor shall provide construction services in accordance with the Statement of Work for Project Number: 546-23-105 – Create Redundancy Capacity in Chiller Plant System. The primary objective of this project is to provide redundant capacity for the existing chilled and condenser water systems and their associated auxiliary systems. This includes adding a new water-cooled chiller, sized for 1,250 tons, on the second level of the building addition and installing a new two-cell cooling tower on the roof. Additionally, electrical gear supporting the new equipment will be located on the third level, and the fourth level will be the housing for an additional Electrical Generator (to be procured under a separate project). The Contractor shall prepare the site for building operations in accordance with the 100% Design, Narrative, Addendum, and Specifications. This includes demolition and removal of existing structures, furnishing labor and materials, and completing all tasks as per this Statement of Work (SOW).

Period of Performance (POP) Dates: 1095 Calendar Days from the notice to proceed (NTP).


PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction.
PRODUCT/SERVICE CODE: Y1NB - Construction of Heating and Cooling Plants.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Feb 25, 2028

NAICS

236220

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Aldwyn Singleton
Contracting Officer

Secondary Contact

Jean Olivier Pierre

Documents

Files (32)

  • 36C24826R0028 0004.pdf

    122 KBAdded in Solicitation version 10Posted
    Download
  • 36C24826R0028 0003.pdf

    84 KBAdded in Solicitation version 8Posted
    Download
  • S4100-1031.pdf

    17 MBAdded in Solicitation version 8Posted
    Download
  • VA Hydrant Inspection Report_out of date.pdf

    4.9 MBAdded in Solicitation version 8Posted
    Download
  • 03 SD-100.pdf

    1.3 MBAdded in Solicitation version 8Posted
    Download
  • SARGENT_10X_Line_Catalog.pdf

    1.0 MBAdded in Solicitation version 8Posted
    Download
  • 04 SC-100.pdf

    1.0 MBAdded in Solicitation version 8Posted
    Download
  • 06 SW-100.pdf

    1.0 MBAdded in Solicitation version 8Posted
    Download
  • 00_CCG_MIAMI_VAMC_B44_IR_E1 30 X 42 - GRID-Key_Planning.pdf

    1.0 MBAdded in Solicitation version 8Posted
    Download
  • fact_sheet_acc_7.pdf

    803 KBAdded in Solicitation version 8Posted
    Download
  • SARGENT_10X_Line_Sell_Sheet.pdf

    478 KBAdded in Solicitation version 8Posted
    Download
  • h6-a-dome-camera-datasheet.pdf

    489 KBAdded in Solicitation version 8Posted
    Download
  • avigilon-unity-h6a-h6x-bullet-camera-datasheet-en.pdf

    437 KBAdded in Solicitation version 8Posted
    Download
  • avigilon-nvr6-form-d-fips- datasheet-en.pdf

    414 KBAdded in Solicitation version 8Posted
    Download
  • 013323a Submittal Register Form.pdf

    417 KBAdded in Solicitation version 8Posted
    Download
  • RFIs Combined 546-23-105 SO.xlsx

    23 KBAdded in Solicitation version 8Posted
    Download
  • 014500a QC Form Attachment.pdf

    70 KBAdded in Solicitation version 8Posted
    Download
  • 36C24826R0028 0002.pdf

    82 KBAdded in Solicitation version 7Posted
    Download
  • S02 - 36C24826R0028 - R1 - Final.pdf

    949 KBAdded in Solicitation version 5Posted
    Download
  • 36C24826R0028 0001.pdf

    84 KBAdded in Solicitation version 5Posted
    Download
  • ATTACHMENT 1 - 100 Bid Final Design Constuction Specification Document 546-23-105 R1.pdf

    30 MBAdded in Solicitation version 5Posted
    Download
  • ATTACHMENT - 3 100 Bid Drawings 546-23-105.zip

    83 MBAdded in Solicitation version 4Posted
    Download
  • ATTACHMENT 2 - 100 CIH Report 546-23-105.zip

    14 MBAdded in Solicitation version 4Posted
    Download
  • ATTACHMENT 4 - GEO Tech Report.zip

    3.4 MBAdded in Solicitation version 4Posted
    Download
  • ATTACHMENT 5 - DBA Wage Determination FL20260215.pdf

    198 KBAdded in Solicitation version 4Posted
    Download
  • ATTACHMENT 8 - EMR.pdf

    127 KBAdded in Solicitation version 4Posted
    Download
  • ATTACHMENT 7 - Specialized Experience Form.pdf

    134 KBAdded in Solicitation version 4Posted
    Download
  • S02 - Attachment 1 - Past Performance Questionnaire.docx

    34 KBAdded in Sources Sought version 3Posted
    Download
  • ATTACHMENT 9 - Past Performance Questionnaire.docx

    34 KBAdded in Solicitation version 4Posted
    Download
  • S02 - 36C24826R0028.pdf

    141 KBAdded in Sources Sought version 3Posted
    Download
  • ATTACHMENT 6 - Limitation of Subcontracting Certificate.docx

    16 KBAdded in Solicitation version 4Posted
    Download
  • S02 - Sources Sought Notice - 36C24826R0028.pdf

    162 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchived

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 7454223e8b2c48099b0fa1acb0bfeca0 on SAM.gov

  2. 4
    Version 4SolicitationArchived

    Type changed from Sources Sought to Solicitation

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 41e5a84b38874961aafb6e6990c9076a on SAM.gov

  3. 5
    Version 5SolicitationArchived

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 22cd2fd58f854810a2d02231ee7821dd on SAM.gov

  4. 6
    Version 6SolicitationArchived

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 964a3e2c32294ffa97119078cf6787ad on SAM.gov

  5. 7
    Version 7SolicitationArchived

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 4de32774e0444118b1416f245a631773 on SAM.gov

  6. 8
    Version 8SolicitationArchived

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 6abf9a1b4cf744bf9e42a05d6a733a92 on SAM.gov

  7. 10
    Version 10SolicitationArchivedCurrent

    Y1NB--FY26: (PROJ: 546-23-105) Create Redundancy Capacity in Chiller Plant System/ Chilled & Condensed Water System Repair/Replacement

    Notice 566da056153847aa9877b549f58b75ad on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Design Build Construction to Replace Seismically Deficient Boiler Plant, Building 8. VAMC Reno, NV. -- Y1NB Replace Seismically Deficient Boiler Plant, Building 8, VAMC Reno, NV. Design Build Construction Solicitation for New CUP. The work includes, but is not limited to: (1) complete Design Build architectural/engineering services to develop final design drawings and construction documents from a previously completed schematic design; (2) construction of a new central utility plant including boilers, chillers, cooling towers, and generators; (3) demolition of the existing boiler plant; and (4) ancillary construction services including parking/pavement, connection to existing utilities, commissioning.
74%
AwardedOpen
The scope of the chilled water plant replacement consists of the demolition of the existing chilled water plant (building 16a) and construction of a new multi-story chilled water plant to include chillers, cooling towers, pumps, and all associated mechanical and electrical equipment. Due to the close proximity of the existing fuel tank farm adjacent to the existing chilled water plant, a new fuel tank farm will need to be constructed as part of the project, which primarily serves the central boiler plant, requiring close coordination with the medical center and ongoing related projects.The scope of the site utility upgrades consists of the replacement and upgrade of the existing fire protection water main and the domestic water main from Campbell Avenue to Building 15. Site utility upgrades also include providing utility main loops of chilled water supply and return, steam supply, condensate return, domestic water supply, and fire protection water supply which will originate from the new chilled water plant and back-feed to Building 1. The work also includes the installation of redundant electrical feeder from the utility demarcation point to Building 19 and coordination with the local electrical utility provider to provide further electrical redundancy offsite as well. In addition, new water storage tanks will be constructed. This project involves civil/site, mechanical, electrical, plumbing, structural, geotechnical, and architectural disciplines. The project must also comply with the DVAs Physical Security Resiliency Design Requirements (PSRDM). It is expected that the chilled water plant will be constructed to meet USGBC LEED Silver certification. The work is located adjacent to and within an active Medical Center campus which will be operational at all times. Impact to on-going operations must be kept to a minimum and carefully coordinated with the Contracting Officer and VAMC staff. In addition, the work area is constrained due to the active medical center operations which will limit laydown and storage areas during construction.
71%
Solicitation11/20/2026
Please see the following page for the solicitation 36C24227R0009 Amendment 0003 regarding Replace Chilled Water Pump at the Boiler Plant JJP VAMC Bronx, NY.
68%
Combined Synopsis11/17/2026
58%
Special NoticeOpen
58%
Solicitation09/24/2026

Additional Details

Solicitation Number

36C24826R0028

Archive Date

Aug 5, 2026

Office Address

TAMPA, FL, 33637