Notice ID: 8ccdc52d2772407f890dccd51aa0e1bdCombined Synopsis/Solicitation
Architect-Engineer Services for Multiple-Award Indefinite Delivery Indefinite Quantity Contracts
Archived on March 31, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:00 PM UTC−04:00
- Posted
- December 29, 2020
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Small Business Set Aside - Partial
- NAICS
- 541310: Architectural Services
- Agency
- General Services AdministrationPUBLIC BUILDINGS SERVICE
Notice details
- Office
- PBS R2 CAPITAL CONSTRUCTION BRANCH
- Place of performance
- Multiple locations: New York, New Jersey, Puerto Rico, the U.S. Virgin Islands (St. Thomas and St. Croix), Connecticut, Rhode Island, Massachusetts, Maine, New Hampshire and Vermont, New York, NY, 10007
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- 47PC0319N0002
- Notice ID
- 8ccdc52d2772407f890dccd51aa0e1bd
Description
The U.S. General Services Administration (GSA), Public Buildings Service (PBS), Northeast and Caribbean Region (Region 2), has a requirement for Multiple-Award, Indefinite Delivery/Indefinite Quantity (IDIQ) contracts for supplemental Architect-Engineering (A/E) services. This Notice is a Request For Qualifications (RFQ) of A/E firms interested in contracting for this work. This procurement will be conducted in accordance with Public Law 92- 582, the Brooks Act, FAR Part 36.6, and GSAM Part 536. This RFQ will result in the award of two (2) Multiple-Award, IDIQ contracts as follows: Contract A will consist of Multiple-Award, A/E IDIQ Contracts for projects with an estimated construction cost at award equal to or greater than $8,000,000. Contract A will cover the geographic areas of the New England Region 1 (States of Maine, Vermont, New Hampshire, Massachusetts, Rhode Island, and Connecticut) and Region 2 (States of New York, Northern New Jersey, Commonwealth of Puerto Rico and U.S. Virgin Islands). (*Northern New Jersey consists of the following counties: Bergen, Essex, Union, Morris, Passaic, Hudson, Middlesex and Monmouth.) Contract A will be procured as full and open competition. Contract B will consist of the Multiple-Award, A/E IDIQ Contracts for projects with an estimated construction cost at award of less than $8,000,000. Contract B will cover the geographic area of Region 2 only (States of New York, Northern New Jersey*, Commonwealth of Puerto Rico and U.S. Virgin Islands). (*Northern New Jersey consists of the following counties: Bergen, Essex, Union, Morris, Passaic, Hudson, Middlesex and Monmouth.) Contract B will be procured as a total small business set-aside. This procurement involves A/E services for various projects that arise on an as-needed basis as part of the functions of GSA PBS, and will cover projects located in the geographic areas listed above. The scope of work may include, but is not limited to, site investigations, site surveys, feasibility studies, Project Development Studies (PDS), Building Evaluation Reports (BER), master plans, engineering studies, concept designs, construction documents, design-build bridging, design-build scope preparation, estimating services, procurement support, record drawings, constructability reviews, technical design reviews, construction administration services, shop drawing review and approval and construction site inspections, post-construction services, and other A/E Services, to include incidental related work in support of Government-administered construction contracts, facility investigations and research, and planning studies. GSA will hold discussions with six (6) to eight (8) of the most highly-rated firms for each Contract pool (A and B). The intent of this procurement is to award up to five (5) contracts to the most technically qualified A/E firms from each Contract pool (A and B). The term for each of the contracts shall be for a period of five (5) years, including a one (1) year base period plus four (4) one-year unilateral options. The aggregate Maximum Order Limitation (MOL) shall not exceed $25,000,000 for the total five-year term of each awarded contract, resulting in an aggregate MOL not to exceed $125,000,000 for each Multiple-Award IDIQ Contract (A and B). The North American Industry Classification System (NAICS) code for this procurement is 541310. The small business size standard for NAICS Code 541310 has average annual gross sales/receipts for the last three years of $8,000,000. Evaluation Factors for Contract A: Interested parties shall submit qualifications in response to the following evaluation factors for Contract A: FACTOR No. 1: SPECIALIZED DESIGN EXPERIENCE (20%): The A/E firm/joint venture shall complete Part 1, Section F & H of the Standard Form 330 for example projects which best illustrate the proposed team’s experience for this contract. The AE firm/joint venture shall submit three (3) projects for which construction is completed not more than 6 years prior to the submission due date of the RFQ, as described below: a) One (1) project that is a major renovation or tenant fit-out in an existing building with a minimum construction cost of $1,000,000. b) One (1) project that is a new building with a minimum construction cost of $10,000,000, which achieved a US Green Building Council (USGBC) Leadership Energy and Environmental Design (LEED) rating of certified or above. Projects that have a higher LEED rating (i.e. silver, gold, or platinum) shall be rated higher for this criteria. c) One (1) Master Plan or Design/Construction Study project with a construction estimate over $1,000,000. *At least one project listed above must be located in Region 2’s Metropolitan NYC area (for the purposes of this acquisition, Metropolitan NYC is defined as the New York counties of New York, Queens, Kings, Staten Island, Westchester, Suffolk and Nassau; the New Jersey counties of Bergen, Essex, Union, Morris, Passaic, Hudson, Middlesex and Monmouth). **If more than one project submitted is located in Region 2’s Metropolitan area, it will receive a higher ranking under Factor 1. Projects that will not be considered for this Factor include water supply-waste treatment facilities; retail stores; warehouses; residential projects; elementary, middle, and/or High School projects; and/or transportation projects. The description for each project shall consist of a narrative describing the specific design approach for the project; and how the client’s program, function, image, mission, budget, schedule, local conditions, sustainable strategies and operations and maintenance objectives were satisfied by the overall design/planning solution (maximum of two single-sided pages per project). Include tangible evidence such as certificates, awards, commendations, peer recognition, etc., demonstrating design excellence. FACTOR NO. 2: DESIGN PHILOSOPHY (20%): This factor is intended to demonstrate the A/E firm’s understanding of GSA’s architectural Design Excellence objectives, the Guiding Principles for Federal Architecture, and the A/E firm/joint venture’s approach to sustainable design. In Part 1, Section ‘H’ of the Standard Form 330, submit; A narrative describing the A/E firm/joint venture’s design philosophy and practical approach to delivering Design Excellence to its clients in a consistent manner. Include a statement by the lead designer on his/her personal commitment to the Guiding Principles for Federal Architecture, GSA’s Design Excellence objectives and sustainable strategies in design. Include a statement to address what design excellence means in projects for this service contract, and how the A/E firm/joint venture will strive to achieve design excellence, as well as its approach to sustainable design (maximum of one single-sided page). FACTOR No. 3: PROFESSIONAL QUALIFICATIONS (20%): In Part 1, Sections ‘C’, ‘E’ & ‘G’ of the Standard Form 330, submit; A narrative (maximum of one single-sided page per each key Team Lead Member) describing the education, qualifications, professional registrations and certifications, and professional experience of the following “key” A/E Firm and/or Team Lead Personnel: Key Team Lead Personnel: Program Executive Lead Architectural Designer Lead MEP Engineer Describe and provide examples of the project experience of proposed key Team Lead Personnel in delivering A/E services comparable to the services contemplated for these contracts. Include any awards, commendations, or peer recognition for Lead Architectural and/or MEP designers. A maximum of three single-sided pages and three projects per key Team Lead Personnel may be submitted. At a minimum, the Key Team Lead Personnel shall have a Bachelor’s Degree and ten (10) years of experience in each respective field, and the Lead Architectural Designer and Lead MEP Engineer shall have a professional license in at least one State of the U.S. Advanced degrees and awards, commendations, or peer recognition for Key Team Lead Personnel in a respective field shall be weighted more heavily for that category. Key Team Members: The evaluation will consider qualifications, relevant project experience and longevity with the firm of key technical personnel in addition to the Key Team Lead Personnel. Technical Personnel must possess the education, qualifications and project experience that will provide the best opportunity for the successful completion of task orders under the proposed contract. The A/E firm/joint venture shall include personnel with professional qualifications in the following disciplines: a) licensed architect b) licensed structural/blast engineer c) licensed mechanical engineer d) licensed electrical engineer e) licensed fire protection engineer f) licensed geotechnical engineer g) hazardous material consultant h) cost estimating consultant For Key Team Members (a) through (f) above, professional qualifications shall be considered to be a Bachelor’s Degree and ten (10) years of experience in each respective field, and have a professional license in at least one State of the U.S. Advanced degrees for Key Team Lead Personnel and Key Team Members in a respective field shall be weighted more heavily for that category. For Key Team Members (g) and (h) professional qualifications shall be considered a minimum of ten (10) years of experience in each respective field, with a degree, advanced degree or relevant certification weighted more heavily for that category. FACTOR No. 4: PAST PERFORMANCE (20%): Independent References: Each A/E firm will be required to provide one (1) completed Past Performance questionnaire prepared by the Owner/Owner Representative for each project submitted in Factor No.1. See appendix for the questionnaire to be prepared by the Owner/Owner Representative. The information submitted in the Standard Form 330 and the questionnaires submitted by the project Owner/Owner Representative will be used to evaluate past performance. *Other project references may be considered. Note that GSA will not limit its reference contacts to those provided by an A/E firm; instead GSA may choose to contact references independent of those provided. GSA will use government-wide past performance evaluation systems such as CPARS (not to exceed 6 years back), etc. FACTOR No. 5: CAPACITY TO ACCOMPLISH THE WORK (15%): The A/E Firm/joint venture shall provide an attachment, under Section ‘D’ of the Standard Form 330, which best illustrates the Organizational Chart of the proposed Team for this contract. All roles, responsibilities and lines of communication shall be defined, clear and efficient. Additionally, the A/E Firm/joint venture shall provide a Project Management Plan, under Section ‘H’ of the Standard Form 330, that will address the following: Demonstrate how it will efficiently and effectively cover all of the anticipated work within the geography of GSA Regions 1 and 2 (States of New York, Northern New Jersey, Maine , Vermont , New Hampshire , Massachusetts , Rhode Island , and Connecticut , the Commonwealth of Puerto Rico and the U.S. Virgin Islands); Demonstrate how it will deal with the scheduling and staffing issues that may result from the issuance of multiple task orders, and assigning Team Leads for multiple projects Explain how the A/E team will ensure project quality and cost control; The Organizational Chart and Project Management Plan shall not exceed four (4) 8-1/2” x 11” single-sided pages (single-spaced, with a minimum 11 point Arial font). FACTOR No. 6: GEOGRAPHIC LOCATION (5%): In order to receive full credit for Factor No. 6, the A/E firm shall demonstrate that, at a minimum, 35% of contract fees for all orders placed under this contract will be performed within a 100-mile radius of GSA Region 2 offices located at One World Trade Center, New York, NY 10007 due to anticipation that a greater percentage of work will be performed within this geographical area. The A/E Firm shall submit a narrative explaining where all proposed architectural and sub-consultant entities for this contract are located. Refer to Factor 3 for team members. If the A/E firm cannot demonstrate a minimum of 35% of contract fees for all orders placed under this contract will be performed within the 100-mile radius, a plan must be provided as part of your proposal, showing the establishment of this office within 45 days after contract award. This plan is intended to demonstrate that the A/E firm has the ability to achieve the 35% geographic location requirement, but will have no bearing on increasing the Factor rating at the time of submission. Evaluation Factors for Contract B: Interested parties shall submit qualifications in response to the following evaluation factors for Contract B: FACTOR No. 1: SPECIALIZED DESIGN EXPERIENCE (20%): The A/E firm/joint venture shall complete Part 1, Section F & H of the Standard Form 330 for example projects which best illustrate the proposed team’s experience for this contract. The A/E firm/joint venture shall submit three (3) projects for which construction was completed not more than 6 years prior to the submission due date of the RFQ, as described below: a) One (1) project that is a tenant fit-out in an existing building with a minimum construction cost of $1,000,000. b) One (1) project that is a new building or a major building modernization with a minimum construction cost of $4,000,000, which achieved a US Green Building Council (USGBC) Leadership Energy and Environmental Design (LEED) rating of certified or above. Projects that have a higher LEED rating (i.e. silver, gold, or platinum) shall be rated higher for this criteria. c) One (1) Pre-Design Study (Master Plan or Feasibility Study), or Design/Construction Study project with a construction estimate over $800,000. *At least one project listed above must be located in Region 2’s Metropolitan NYC area (for the purposes of this acquisition, Metropolitan NYC is defined as the New York counties of New York, Queens, Kings, Staten Island, Westchester, Suffolk and Nassau; the New Jersey counties of Bergen, Essex, Union, Morris, Passaic, Hudson, Middlesex and Monmouth). **If more than one project submitted is located in Region 2’s Metropolitan area, it will receive a higher ranking under Factor 1. Projects that will not be considered for this Factor include water supply-waste treatment facilities; retail stores; warehouses; residential projects; elementary, middle, and/or High School projects; and/or transportation projects. The description for each project shall consist of a narrative describing the specific design approach for the project; and how the client’s program, function, image, mission, budget, schedule, local conditions, sustainable strategies and operations and maintenance objectives were satisfied by the overall design/planning solution (maximum of two single-sided pages per project). Include tangible evidence such as certificates, awards, commendations, peer recognition, etc., demonstrating design excellence. FACTOR NO. 2: DESIGN PHILOSOPHY (20%): This factor is intended to demonstrate the A/E firm’s understanding of GSA’s architectural Design Excellence objectives, the Guiding Principles for Federal Architecture, and the A/E firm/joint venture’s approach to sustainable design. In Part 1, Section ‘H’ of the Standard Form 330, submit; A narrative describing the A/E firm/joint venture’s design philosophy and practical approach to delivering Design Excellence to its clients in a consistent manner. Include a statement by the lead designer on his/her personal commitment to the Guiding Principles for Federal Architecture, GSA’s Design Excellence objectives and sustainable strategies in design. Include a statement to address what design excellence means in projects for this service contract, and how the A/E firm/joint venture will strive to achieve design excellence, as well as its approach to sustainable design, (maximum of one single-sided page). FACTOR No. 3: PROFESSIONAL QUALIFICATIONS (20%): In Part 1, Sections ‘C’, ‘E’ & ‘G’ of the Standard Form 330, submit; A narrative (maximum of one single-sided page per each Key Team Lead Member) describing the education, qualifications, professional registrations and certifications, and professional experience of the following “key” A/E Firm and/or Team Lead Personnel: Key Team Lead Personnel: Program Executive Lead Architectural Designer Lead MEP Engineer Describe and provide examples of the project experience of proposed Key Team Lead Personnel in delivering A/E services comparable to the services contemplated for these contracts. Include any awards, commendations, or peer recognition for Lead Architectural and/or MEP designers. A maximum of three single-sided pages and three projects per Key Team Lead Personnel may be submitted. At a minimum, the Key Team Lead Personnel shall have a Bachelor’s Degree and ten (10) years of experience in each respective field, and the Lead Architectural Designer and Lead MEP Engineer shall have a professional license in at least one State of the U.S. Advanced degrees and awards, commendations, or peer recognition for Key Team Lead Personnel in a respective field shall be weighted more heavily for that category. Key Team Members: The evaluation will consider qualifications, relevant project experience and longevity with the firm of key technical personnel in addition to the Key Team Lead Personnel. Technical Personnel must possess the education, qualifications and project experience that will provide the best opportunity for the successful completion of task orders under the proposed contract. The A/E firm/joint venture shall include personnel with professional qualifications in the following disciplines: a) licensed architect b) licensed structural/blast engineer c) licensed mechanical engineer d) licensed electrical engineer e) licensed fire protection engineer f) licensed geotechnical engineer g) hazardous material consultant h) cost estimating consultant For Key Team Members (a) through (f) above, professional qualifications shall be considered to be a Bachelor’s Degree and ten (10) years of experience in each respective field, and have a professional license in at least one State of the U.S. Advanced degrees for Key Team Lead Personnel and Key Team Members in a respective field shall be weighted more heavily for that category. For Key Team Members (g) and (h) professional qualifications shall be considered a minimum of ten (10) years of experience in each respective field, with a degree, an advanced degree or relevant certification weighted more heavily for that category. FACTOR No. 4: PAST PERFORMANCE (20%): Independent References: Each A/E firm will be required to provide one (1) completed Past Performance questionnaire prepared by the Owner/Owner Representative for each project submitted in Factor No.1. See appendix for the questionnaire to be prepared by the Owner/Owner Representative. The information submitted in the Standard Form 330 and the questionnaires submitted by the project Owner/Owner Representative will be used to evaluate past performance. *Other project references may be considered. Note that GSA will not limit its reference contacts to those provided by an A/E firm; instead GSA may choose to contact references independent of those provided. GSA will use government-wide past performance evaluation systems such as CPARS (not to exceed 6 years back), etc. FACTOR No. 5: CAPACITY TO ACCOMPLISH THE WORK (15%): The A/E Firm/joint venture shall provide an attachment, under Section ‘D’ of the Standard Form 330, which best illustrates the Organizational Chart of the proposed Team for this contract. All roles, responsibilities and lines of communication shall be defined, clear and efficient. Additionally, the A/E Firm/joint venture shall provide a Project Management Plan, under Section ‘H’ of the Standard Form 330, that will address the following: Demonstrate how it will efficiently and effectively cover all of the anticipated work within the geography of GSA Regions 2 (States of New York and Northern New Jersey, the Commonwealth of Puerto Rico and the U.S. Virgin Islands); Demonstrate how it will deal with the scheduling and staffing issues that may result from the issuance of multiple task orders, and assigning Team Leads for multiple projects. Explain how the A/E team will ensure project quality and cost control; The Organizational Chart and Project Management Plan shall not exceed four (4) 8-1/2” x 11” single-sided pages (single-spaced, with a minimum 11 point Arial font). FACTOR No. 6: GEOGRAPHIC LOCATION (5%): For Factor No. 6, the A/E firm shall demonstrate that at a minimum 35% of contract fees for all orders placed under this contract will be performed within a 100-mile radius of GSA Region 2 offices located at 1 World Trade Center, New York, NY 10007 due to anticipation that a greater percentage of work will be performed within this geographical area. The A/E Firm shall submit a narrative explaining where all proposed architectural and sub-consultant entities for this contract are located. Refer to Factor 3 for team members. If the A/E firm cannot demonstrate a minimum of 35% of contract fees for all orders placed under this contract will be performed within the 100-mile radius, a plan must be provided as part of your proposal, showing the establishment of this office within 45 days after contract award. This plan is intended to demonstrate that the A/E firm has the ability to achieve the 35% geographic location requirement, but will have no bearing on increasing the Factor rating at the time of submission. Submission Requirements: Interested firms having the capabilities to perform this work must respond by submitting a Letter Of Interest, Standard Form 330 (SF 330) Architect-Engineer Qualifications Parts I and II in electronic PDF format along with supporting data that specifically responds to the evaluation factors of the RFQ. The SF 330 shall be limited to 50 pages (8 ½”x11” pages) for the entire A/E team proposed. Specify in your Letter of Interest which Contract (A or B) you are responding to. All SF 330s must be signed and current reflecting a date not more than one (1) year from the date of this notice. All example projects provided in the SF 330 must be completed by the office/branch/individual team member actually performing the work under this contract. Projects not performed by the office/branch/individual team member will be excluded from evaluation consideration. The SF 330 must clearly state the office/branch/individual team members performing the work on all projects presented. All responsive submissions will be evaluated by a Technical Evaluation Board (TEB). The firms will be ranked with the highest rated proposals on the top of the list. After the evaluation of the submissions, GSA will shortlist six (6) to eight (8) of the most highly rated firms from each Contract (A and B). The shortlisted firms will be invited for interviews and further evaluated prior to recommendation and approval of the selected A/E firm(s). The shortlist will be advertised on Beta.SAM.gov. The firms must ensure the SF 330 Architect-Engineer Qualifications Parts I and II reflect the entire design team. Rate/price proposal(s) will be requested following the selection of the most technically qualified firm(s) from each Contract (A and B). (Note; the shortlisted A/E firms will be required to provide an electronic copy of the A/E’s Small Business Subcontracting Plan for Contract A submissions if the awardee is a large or other-than-small business. The Small Business Subcontracting Plan template will be provided to the shortlisted firms for Contract A.) Requirements of Joint Ventures: (1) All qualifications packages submitted by joint ventures must include a copy of an executed joint venture agreement (with original signatures) which fully discloses the legal identity of each member of the joint venture, the relationship between the members, the form of ownership of each member, and any limitations on liability or authority for each member. (2) An authorized representative of each member of the joint venture must sign the contract accompanying an offer regardless of any agency relationship established between the members. (3) In the case of corporations that are joint venture members, the corporation secretary must certify that the corporation is authorized to participate in the joint venture, either by so certifying in the joint venture agreement, or by submitting a separate certification to the Government. The joint venture must also provide a certificate that identifies a principal representative of the joint venture with full authority to bind the joint venture. (4) Representations and certifications and financial information must be submitted for each member of the joint venture. Firms which desire consideration and meet the requirements described in this RFQ are invited to submit the complete qualifications package. All submissions must be sent via email to Jordana Covrigaru, Contracting Officer, at jordana.covrigaru@gsa.gov, with a copy to Brad Edwards, Contract Specialist, at brad.edwards@gsa.gov. Only electronic PDF submissions will be considered. No late submissions will be accepted. ALL SUBMISSIONS ARE DUE by 3PM local time on March 10, 2020. The deadline for all Requests for Information (RFI) is 3:00PM local time on February 19, 2020. All RFIs must be submitted in writing via email to the Contracting Officer. For informational purposes: All offerors are required to have an active registration in the System for Award Management (SAM) (www.sam.gov) at the time of offer submission. If you have any questions regarding this procurement, please contact Jordana Covrigaru, Contracting Officer, at jordana.covrigaru@gsa.gov, or Brad Edwards, Contract Specialist, at brad.edwards@gsa.gov.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
No documents available.
Lifecycle
Solicitation:
47PC0319N0002- Market Research
- Combined Synopsis
- Market ResearchMay 31, 2019
Architect-Engineer Services for Multiple-Award Indefinite Delivery Indefinite Quantity Contracts
- 9×Combined SynopsisCurrentJan 23, 2020
Architect-Engineer Services for Multiple-Award Indefinite Delivery Indefinite Quantity Contracts
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Description The purpose of this announcement is to request new Architect / Engineer (A/E) qualification information for the General Services Administration / Public Buildings Service (GSA/PBS) A/E short selection for Continental United States (CONUS) and Outside Continental United States (OCONUS). WHAT IS THE SHORT SELECTION PROCESS? The short selection process utilizes the procedures set forth in Revolutionary FAR Overhaul (RFO) Federal Acquisition Regulation (FAR) Subsection 36.202-4 for Architect/Engineer (A/E) projects with an estimated total fee less than the simplified acquisition threshold (currently $350,000; see RFO FAR Part 2.101). The A/E's professional qualifications, the firm's geographic proximity, knowledge of the local area as identified on the A/E's SF330, and supplemental information will be used for the first preliminary screening of firms. For each proposed project, GSA will conduct discussions with at least three (3) firms to consider anticipated concepts and compare alternative methods for furnishing services. Additional information may be requested during discussions if necessary to facilitate the final ranking of firms (i.e.: past performance references, specialized experience, capacity, schedule, etc.). Upon conclusion of discussions, the top three firms will be ranked, and a price proposal will be requested from the highest ranked firm. If a fair and reasonable price cannot be negotiated with the highest ranked firm, a request for a price proposal will be sent to the second ranked firm, and so on until an award can be made at a fair and reasonable price. All acquisitions utilizing the GSA A/E short selection list (database) shall be set-aside for small business concerns unless requirements cannot be met by a small business and the Contracting Officer (CO) obtains a proper waiver. WHAT IS THE SHORT SELECTION PROCESS USED FOR? GSA will use the short selection list to award A/E contracts, valued at less than the simplified acquisition threshold (currently $350,000) in CONUS/OCONUS (NOT Estimated Cost of Construction at Award (ECCA). The firm must have NAICS code 541310 - Architectural Services, with a small business size standard of $12.5 million and/or 541330 - Engineering Services, with a small business size standard of $25.5 million. The firm must clearly notate which states/territories they have active production offices and which states they are licensed by November 1, 2026. Most work will be executed for repair and alteration projects within existing Federal Buildings and U.S. Courthouses. The estimated cost of construction at award (ECCA) for a majority of the project requirements could range from, but are not limited to, above micro-purchase threshold for construction (currently $2,000) to annual prospectus threshold (currently $3.961M) or higher. Fees for design services cannot exceed 6% of the ECCA. For more information about the 6% fee limitation, see FAR 15.404-9(c)(4)(ii) (GSA Class Deviation RFO-2025-15) and 41 U.S.C. 3905(b)(3). GSA manages a nationwide real estate portfolio of approximately 360 million rentable square feet, including preserving more than 500 historic properties nationwide. A broad range of services potentially requested under this short list may include, but are not limited to the following: 1. Core Project Life Cycle Services - These services cover the entire project lifecycle, from initial concept to post-construction closeout. Planning and Pre-Design Feasibility, pre-design, and project development studies Master planning Cost estimating Real estate market analysis Assessment and Investigation Existing conditions surveys, and field investigation Building condition survey evaluation reports (exterior and interior) Environmental investigation, reviews, inventories, and audits Energy audits and studies Design and Documentation Concept design, design development, and construction document development (both architectural and engineering) Interior design, including furniture, fixtures, and equipment (FFE) Building standard documents Construction Support and Closeout Constructability review and evaluation Submittal and shop drawing review Management and inspection (M&I) services during construction and construction inspection Building and system commissioning Post construction contract Services (PCCS); Record and close-out documents 2. Specialized Technical & System Design - Work requested often involves the assessment, repair, and upgrade of existing complex building systems. Mechanical, Electrical, and Plumbing (MEP) Full MEP services, including design of HVAC systems, electrical systems, and lighting Assessment and design for mechanical components (e.g., pumps, fans, air handlers, water distribution systems) and air distribution Design of water and waste water systems, including performance of sanitary inspections Temperature control assessment and design and BAS system assessment and integration Building Structure and Envelope Structural evaluation and design Façade evaluation and remediation design Water infiltration investigation and mitigation design safety, security, and compliance Fire and life safety evaluation and design Rehabs to improve energy efficiency and safety concerns Seismic & blast protection and vertical transportation Code compliance 3. A/E Disciplines and Expertise - A/E firms will need staff with licensed and/or specialized expertise. The following are typical disciplines and categories utilized for GSA projects. Firms do not need to have all of them, but should include the most relevant disciplines for their firm: Core Architectural and Engineering Disciplines Architecture and anterior architecture Mechanical engineering, electrical engineering, structural & civil engineering, and plumbing Historic architecture/preservation Specialized Expertise A qualified/licensed fire protection engineer (NCEES)* Security Space planning & workplace Cost estimating and scheduling Environmental services Building automation Scifs Modernization and Quality Control Building information modeling (BIM) Quality control review and report writing SUBMISSION INSTRUCTIONS To be considered for future Architect-Engineer (A/E) projects, your firm must submit a package demonstrating the applicability and comparability of its portfolio to the types of services outlined above. Please submit your complete package as a single PDF document. This file, which should be no larger than 30MB and no more than thirty (30) pages, must contain all submittal documents. Submit your PDF file as an attachment via the online “GSA A/E Short Selection Submission Form” (Link provided below). Note: Hardcopy submissions received by mail will not be filed or considered. The following information shall be submitted as part of the thirty (30) page limit (LISTED IN REQUIRED ORDER): DO NOT SUBMIT ANY PROPRIETARY INFORMATION 1. A cover letter. The letter should outline the work your firm specializes in and include a brief description of your firm's capabilities specifically related to the project examples stated above. 2. SAM Entity Registration Print Out - 1st and 2nd page only to show active registration in System for Award Management (SAM). Registration is required for award of federal contracts and you must have an active registration in SAM to be considered for project work. Contractors may register in SAM free of charge at https://sam.gov/ under the header labeled Register Your Entity or Get a Unique Entity ID. 3. Standard Form (SF) 330 - Architect-Engineer Qualifications. DO NOT include subconsultants. Please include photos of accomplished work. 4. A separate list of the licensed (or will be licensed by November 1, 2026) professionals and the State/territories of their licensing. Note: This A/E short selection process is for Primes only; consultants are NOT part of this selection process. However, submitted project experience may reference work executed with consultants. Firms should highlight their specific role and explain the work they performed alongside any consultants. Consultants will be requested by project managers during project development. Submittals that don't contain the required documentation will be returned for revision and/or non selection. Organizing your submittal package in the same order enumerated above will facilitate a more efficient review process. Questions related to this announcement shall be referred to aeshortselection@gsa.gov The following information should be easily found in your SF330 Submission: 1. Relevant Project Experience, Demonstrated Comparability and Creative Problem Solving Offerors must provide a minimum of three (3) but no more than five (5) comparable project examples that demonstrate a wide range of repair and alterations work similar in budgets and complexities to those anticipated for contracts. An additional maximum of ten (10) relevant projects completed in the last ten (10) years can be submitted in list form. Please include relevant project photographs. A comparable project is defined as an “A/E engagement involving the repair, alteration, or renovation of existing, occupied facilities, with a focus on both architectural and engineering solutions. Specifically, the project should demonstrate specialized experience in: Building system upgrades (e.g., MEP services or mechanical pump replacement) Historic preservation (especially classical building architecture) Workplace design Furthermore, a comparable project's Estimated Cost of Construction at Award (ECCA) should generally range from $50,000 to an annual prospectus threshold (currently $3.961M). Breadth of Scope: Teams must demonstrate proficiency in seamlessly incorporating architecture and engineering to solve both complex and routine design issues within existing buildings. Specialized Expertise: Highlight specialized experience in the areas most critical to the GSA/PBS mission. This must include work in: Occupied buildings Historic preservation, restoration, and adaptive reuse (special consideration will be given to firms demonstrating experience with classical building architecture and design) Building system upgrades (e.g., MEP services, mechanical pump replacement, HVAC systems, electrical systems, and building controls). Workplace design strategies, interior office redesign, and building standard documents Creative Problem Solving: Firms must demonstrate their ability to be creative and "think outside the box" when developing design solutions, especially given the constraints and challenges of government buildings and existing customer agencies while successfully navigating constraints such as schedule and budget. 2. Team Capacity, Management, and Quality Control The team’s ability to manage projects efficiently, flexibly, and collaboratively is essential for handling the unpredictable nature of GSA task orders. Contract Management and Flexibility: Demonstrate the ability to staff and manage contracts on an as-needed basis, accounting for the unpredictable issuance of work in terms of number, size, importance, and urgency. Consultant and Customer Agency Management: The A/E short selection process is for the Architecture or Engineering Prime only, but the firm must demonstrate its ability to manage its entire team. Firms must demonstrate proven success in establishing good relationships with and effectively managing future sub-consultants, as well as managing scope and communication while working with difficult customer agencies. Quality Assurance: Team must demonstrate formalized processes for quality control (QC) and a commitment to QC standards while consistently designing within the project’s budget and schedule limitations. 3. Key Personnel Education and Qualifications Key Personnel should possess the education, professional qualifications, and specific project experience that provides the best opportunity for the successful completion under this contract. Licensing: Provide a separate list of states in which the firm is licensed or will be licensed by November 1, 2026. Specialized Roles: Key Personnel must demonstrate expertise in disciplines relevant to the services outlined above, such as a Qualified Fire Protection Engineer1, historic preservation, etc. 1A Qualified Fire Protection Engineer is an individual with deep knowledge of fire physics and chemistry, meeting one of the following criteria: (a) An engineer with an undergraduate or graduate degree in fire protection/safety engineering, plus a minimum of four (4) years of relevant work experience; (b) A registered Professional Engineer (P.E. or similar) in Fire Protection Engineering; or (c) A P.E. in a related engineering discipline who is a Professional Member of the Society of Fire Protection Engineers and has passed the NCEES fire protection exam. 4. Past Performance Offerors should include CPARS (Contractor Performance Assessment Reporting System) if they have past government experience as the prime. No more than three (3) most recent relevant records. The CPARS information does not count against the thirty (30) page limit. Impact: If a firm does not have past government experience, they will not be negatively impacted during the selection process. Please register to attend the industry outreach and Q&A meeting on October 16 at 9am PDT or October 22 at 3pm EDT by completing the “A/E Short Selection Process Registration Form CONUS/OCONUS” (Link provided below). Invites will be sent out to all registered attendees approximately one week in advance. Relavant Links GSA A/E Short Selection Process for CONUS/OCONUS - Registration Form https://forms.gle/8kd1qZfZeVMag3HG9 GSA A/E Short Selection Process for CONUS/OCONUS - Q&A https://docs.google.com/document/d/1sGIs_KEnEvP99mxeB2VKBS64IVoUixEZSOLsczc_2As/edit?usp=sharing GSA A/E Short Selection Process for CONUS/OCONUS - Submission Form https://forms.gle/7Rh3FkMkubweUHveA | - | Market Research | 10/31/2026 |
| - | Awarded | Open | |
This is a Sources Sought Notice only. This notice does not constitute a Request for Qualifications (RFQ), Request for Proposals (RFP), or Invitation for Bids (IFB), nor does it represent a commitment by the Government to issue a solicitation or award a contract. This Sources Sought Synopsis is issued solely for market research and planning purposes to determine the availability and adequacy of potential sources. It is not a Request for Proposals or Quotes and imposes no obligation on the Government to acquire any goods or services. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The Government reserves the right to determine the appropriate acquisition approach based on the results of this market research. Responders should not anticipate feedback regarding their submissions. The Government will not pay for any costs incurred in responding to this Synopsis; all costs associated with responding are solely at the responding party's expense. The information provided herein is subject to change and is non-binding on the Government. The purpose of this notice is to conduct market research to identify potential and qualified sources, assess industry capabilities, and establish effective acquisition strategies, including potential small business set-aside opportunities. No reimbursement will be provided for any costs associated with submitting information in response to this announcement or any follow-up information requests. Overview The General Services Administration (GSA), Public Buildings Service (PBS), is conducting market research to establish Multiple-Award Indefinite-Delivery, Indefinite-Quantity (IDIQ) contracts for comprehensive, multidisciplinary Architect-Engineer (A/E) services. These contracts are intended to provide integrated, sustainable, and adaptive design solutions across federally owned and leased real property nationwide. The Government anticipates awarding multiple contracts with multi-year ordering periods (5 year base with one 5 year option) to support GSA zones and client agencies across the United States and its territories. Expected typical project size is to be above the simplified acquisition threshold of $350,000. The potential place of performance for services rendered under this contract is on an as-needed basis for federal projects anywhere in the United States and its territories. This will require the capability to travel to GSA and other Government agency office locations nationwide. In some instances, performance of services is expected to require the capability for contractors to dispatch personnel to multiple locations simultaneously. The applicable North American Industry Classification System (NAICS) code for this requirement is 541310 (Architectural Services) & 541330 (Engineering Services), which has a small business size standard of $12.5 million and $25.5 million respectively. Scope of Services Services provided under the resulting IDIQ contracts will encompass a comprehensive range of professional A/E design and engineering disciplines. Scopes of work for individual task orders may include, but are not limited to, the following: 1. Core Project Life Cycle Services - These services cover the entire project lifecycle, from initial concept to post-construction closeout. Planning and Pre-Design Feasibility, pre-design, and project development studies Master planning Cost Estimating Real Estate Market Analysis Assessment and Investigation Existing conditions surveys, and field investigation Building condition survey evaluation reports (exterior and interior) Environmental investigation, reviews, inventories, and audits Energy audits and studies Design and Documentation Concept design, Design development, and Construction document development (both architectural and engineering) Interior design, including Furniture, Fixtures, and Equipment (FFE) Building standard documents Construction Support and Closeout Constructability review and evaluation Submittal and shop drawing review Management and inspection (M&I) services during construction and Construction inspection Building and system commissioning Post Construction Contract Services (PCCS); Record and close-out documents 2. Specialized Technical & System Design - Work requested often involves the assessment, repair, and upgrade of existing complex building systems. Mechanical, Electrical, and Plumbing (MEP) Full MEP services, including design of HVAC systems and electrical systems and lighting Assessment and design for mechanical components (e.g., pumps, fans, air handlers, water distribution systems) and air distribution Design of water and waste water systems, including performance of sanitary inspections Temperature control assessment and design and BAS system assessment and integration Building Structure and Envelope Structural evaluation and design Façade evaluation and remediation design Water infiltration investigation and mitigation design Safety, Security, and Compliance Fire and Life Safety evaluation and design Rehabs to improve energy efficiency and safety concerns Seismic & Blast protection and Vertical Transportation Code Compliance 3. Required AE Disciplines and Expertise - AE firms will need staff with licensed and/or specialized expertise in the following disciplines: Core Architectural and Engineering Disciplines Architecture and Interior Architecture Mechanical Engineering, Electrical Engineering, Structural & Civil Engineering, and Plumbing Historic Preservation Specialized Expertise A Qualified/Licensed Fire Protection Engineer (NCEES)* Security Space Planning & Workplace Cost Estimating and Scheduling Environmental Services Modernization and Quality Control Building Information Modeling (BIM) Quality control review and Report writing Submission Requirements Interested firms are invited to submit a written Capability Statement. Submissions must not exceed five (5) pages in length and must address the following elements: A. Company Profile Official company name, street address, telephone number, and primary website URL. Unique Entity Identifier (UEI) and Commercial and Government Entity (CAGE) Code. Office location(s) and primary design production facilities. Business size status under NAICS 541310 or 541330 (Large Business or Small Business). Applicable SBA socio-economic certifications (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business [SDVOSB], Woman-Owned Small Business [WOSB], or Economically Disadvantaged WOSB [EDWOSB]). B. Relevant Experience Summarize three to five (3–5) relevant projects completed within the past ten (10) years. Demonstrate experience in projects of similar scale, scope, and complexity, such as federal workplace design, major repairs and alterations, or complex building systems. Include project title, customer/agency point of contact, contract value, role (Prime or Subcontractor), and a brief narrative of the work performed. C. Nationwide Capacity Demonstrate organizational capacity to manage and execute multiple task orders simultaneously across diverse geographic locations nationwide. Describe key disciplines maintained in-house versus those typically fulfilled through subcontractor or joint venture arrangements. Submission Instructions Responses must be submitted electronically via email to the primary procurement contacts listed below: Submission Deadline: Primary Contact: Point of Contact Email: Subject Line Format: Sources Sought Response - National A/E IDIQ - [Firm Name] Hard copies, telephonic inquiries, and late submissions will not be reviewed or acknowledged. All information provided in response to this notice will be used strictly for market research and acquisition planning purposes. This notice encourages participation from qualified small business concerns, including socio-economic program participants, to assist GSA in evaluating the feasibility of small business set-asides for this procurement. All prospective offerors are responsible for monitoring SAM.gov for updates, future notices, or potential solicitations related to this requirement. | - | Market Research | 11/13/2026 |
The US Army Corps of Engineers, New York District (NYD) intends to issue a solicitation package seeking to award one Indefinite Delivery Indefinite Quantity (IDIQ) contract for the Chemical Testing of Dredged Material. The IDIQ contract would include the sampling and testing of dredged material proposed for placement at the Historic Area Remediation Site (HARS). HARS sampling and testing would adhere to the procedures, and their subsequent updates, as described in: 2016 US Army Corps of Engineers New York District/EPA Region 2 Guidance for Performing Tests on Dredged Material Proposed for Ocean Disposal (a.k.a. Regional Testing Manual) (http://www.nan.usace.army.mil/Portals/37/docs/regulatory/Formdoc/FINAL_NYD-R2_REGIONAL_TESTINGMANUAL-APRIL%202016.pdf) 1991 EPA/USACE, Evaluation of Dredged Material Proposed for Ocean Disposal (a.k.a. the Green Book) (https://www.epa.gov/sites/production/files/2015-10/documents/green_book.pdf). The IDIQ contract would also include the sampling and testing of dredged material proposed for upland placement. “Upland” sampling and testing would adhere to the procedures, and their subsequent updates, as described in: New Jersey Department of Environmental Protection (NJDEP) New Jersey Administrative Code (NJAC), Title 7, Chapters 9 and 26 (a.k.a. ‘NJAC 7’) (https://dep.nj.gov/rules/current-rules-and-regulations/) New York State Department of Environmental Conservation (NYSDEC) manual, entitled “Technical & Operational Guidance Series (TOGS) 5.1.9 In-Water and Riparian Management of Sediment and Dredged Material” (November 2004) (a.k.a. ‘TOGS 5.1.9’) (https://www.dec.ny.gov/docs/water_pdf/togs519.pdf) New York State Department of Environmental Conservation, New York Codes, Rules and Regulations (NYCRR), Title 6, Part 375 (December 2025) (a.k.a. ‘6 NYCRR Part 375’) (https://dec.ny.gov/sites/default/files/2025-12/6nycrrpart375final.pdf). Other state procedures may also be requested and would be coordinated between NYD and the contractor to determine capabilities. Additional work under this contract will include analyses of sediment, tissue, and water and may include environmental DNA/metagenomic analyses related to HARS monitoring in accordance with the following document and any subsequent updates: U.S. Army Corps of Engineers (USACE) New York District and Environmental Protection Agency (EPA) Region 2, Site Management and Monitoring Plan for Historic Area Remediation Site (HARS) (July 2020). Task orders would include all or some of the following: sediment and water collection (on Contractor-supplied ship) handling, processing and shipping of samples physical and chemical analyses quality assurance (QA) and quality control (QC) procedures, and necessary corrective actions. For each task order, the contractor would provide reports containing the sampling logs, all testing results and QA/QC information in the format required by NYD, EPA – Region 2, and/or state agencies. In addition to sampling and testing for ocean placement, NYD also requires that contractors be capable of performing testing procedures such as the Synthetic Precipitation Leaching Procedure (SPLP), the Toxicity Characteristic Leaching Procedure (TCLP), and the Modified Elutriate Test (MET), which are required for upland placement of dredged material in the states of New York and New Jersey. Prior to sampling and testing, a Work/Quality Assurance (QA) Plan and an Accident Prevention Plan (APP) would need to be prepared by the contractor and approved by NYD. A Work/QA Plan must include: descriptions of all technical procedures for field sampling, laboratory analyses (e.g. biological, physical) for HARS and upland testing, data reduction and validation, and reporting clearly written standard operating procedures (SOP) for all field, experimental and analytical procedures clearly defined QA objectives that are consistent with the regulations (e.g. Regional Testing Manual, Green Book, NJAC 7, TOGS 5.1.9, and 6 NYCRR Part 375) and if applicable, permit application mechanisms for conducting performance and systems audits during the course of the field laboratory work procedures for detecting problems with sampling and analytical work, and implementation of corrective actions in a timely manner. All sampling would be performed within the Port of New York & New Jersey, all Federal Navigation Channels within New York District, the length of the Hudson River, in the Atlantic Ocean at the Historic Area Remediation Site and its Mud Dump Reference Site. “New Work or Harbor Deepening” projects may be proposed and coordinated between NYD and the contractor. A detailed description of work required for these contracts will be provided in its entirety upon issuance of the complete solicitation. Prior to issuance of the solicitation, it is highly recommended that interested parties read the required regulations (e.g. Regional Testing Manual, Green Book, NJAC 7, TOGS 5.1.9, and 6 NYCRR Part 375) in order to obtain a thorough understanding of the work required by the NYD and EPA – Region 2 dredged material testing program. The Period of Performance will be five (5) years from the issuance of the Notice to Proceed (NTP). The contract magnitude will be up to $10,000,000.00 for five (5) years – up to $2,000,000.00 each year. One contract will be awarded on an Unrestricted Full and Open Competition basis to the lowest bidder who has, within the last 18 months, demonstrated their capability of performing the program’s work to EPA – Region 2. A bidder can prove their capability through one of the following: the bidder has received, within the last 18 months from EPA – Region 2, documentation stating that the laboratory has submitted data that is fully acceptable or acceptable with qualification; or the bidder has satisfied the Demonstration of Capability (DOC) requirements for the NYD and EPA – Region 2 dredged material testing program. The North American Industry Classification System (NAICS) code is 541380. The business size standard is $25,500,000. | - | Pre-Solicitation | 11/23/2026 |
Elevator Inspections Base 4 Canandaigua VA Medical Center VAMC Bath VA Medical Center VAMC | - | Combined Synopsis | 11/13/2026 |
Additional Details
Solicitation Number
47PC0319N0002
Archive Date
Mar 31, 2021
Office Address
NEW YORK, NY, 10007