GovChime
Notice ID: 6215a4feb53942a7ac1ae08c6c02a054Combined Synopsis/SolicitationArchived

J045--Drain and Grease Trap Maintenance

Archived on September 15, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
1:00 PM EDT
Posted
September 4, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
562998: All Other Miscellaneous Waste Management Services
Agency
Department of Veterans Affairs

Notice details

Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Place of performance
James A. Haley Veterans' Hospital (JAHVH), Tampa, Florida, 33612
PSC
J045: MAINT/REPAIR/REBUILD OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24826Q0936
Notice ID
6215a4feb53942a7ac1ae08c6c02a054

Description

Drain & Grease Trap Maintenance - JAHVH Questions and Answers for RFQ# 36C24826Q0936 The PWS states that the contractor is to jet lines from the Interceptor/Trap to the source inside the building for Buildings 1, 38, and 100. Please identify the specific lines to be jetted. Are these the kitchen drain lines leading to each grease interceptor, lift-station lines, or other piping? Please also provide the estimated linear footage for each building. Answer: There are various styles of piping throughout JAHVH campus. Building 1 to grease interceptor is roughly 75ft. Building 38 to pump is roughly 200 ft. due to hose length and must be clean as this will be exposed throughout the building. Building 100 grease interceptors require confined entry and cleaning due to baffle system. Please provide any available site maps, as-built drawings, or line diagrams identifying the locations, routes, pipe diameters, pipe materials, cleanouts, manholes, and other access points for the grease, sanitary, and stormwater lines. Answer: Only available mapping we are able to retrieve are the Sanitary and Storm Sewers Sitemaps (Please see Attachment 3 Site-Map Sanitary and Storm Sewers). For the 1,000 linear feet of stormwater lines and 3,000 linear feet of sanitary lines, please identify the specific sections or locations included. Does scope, clean, and maintain require CCTV inspection both before and after cleaning, and is a recorded video or written inspection report required? Answer: Please see Sitemap for Sanitary and Storm Sewer. Yes, scope, clean, maintain requires CCTV inspection, along with final report on completion. Please clarify the quarterly routine services required for the eight lift stations. Does the service include wet-well pumping and cleaning, jetting of connected piping, pump inspection, float testing, control-panel inspection, electrical testing, and removal and disposal of accumulated waste? Answer: Yes, while conducting routine services on the 8 lift stations, all required personnel are to be on site when conducting routine maintenance on the lift stations (pumping/service technicians/etc.). Please clarify whether repair parts, replacement components, disposal costs, and corrective repairs identified during scheduled maintenance are included in the firm-fixed unit prices or are to be separately authorized and compensated. For the twenty emergency-service calls, please also identify the expected pricing basis and whether each call is to include labor, equipment, travel, parts, pumping, and disposal. Answer: Yes, repair parts/components, disposal costs, and corrective repairs identified during a routine service are included in the firm-fixed price as this is to maintain OEM/Industry standards. Regarding Emergency/after hour calls, it is to include labor, equipment, travel, parts, pumping, jetting (up to 3000 linear ft.), and disposal of items as described in the PWS. We are reviewing the Performance Work Statement and noted the requirement for contractors to arrive onsite within two (2) business hours of the original emergency service call. For planning purposes, can you please clarify whether offerors should demonstrate how they will consistently meet the required onsite response time throughout the contract period, particularly for emergency and after-hours service calls? Answer: Yes, when dispatched an Emergency/after hour call, the Contractor need to arrive on-site withing two (2) hours due to patient care and environmental safety regulations. Demonstrations include live updates between dispatchers and JAHVH staff members when they are in-route to JAHVH, along with any additional personnel to address the emergency request.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Jose E. Ortiz-Velez
Senior Contracting Officer

Documents

Files (10)

  • C01 AWARD NOTICE DESCRIPTION (002).docx

    23 KBAdded in Combined Synopsis/Solicitation version 7Posted
    Download
  • S04 SITE-VISIT SIGN IN SHEET.pdf

    1005 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • S04 SITE-VISIT SIGN IN SHEET.pdf

    1005 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • Attachment 3 - Site Map SanitaryStorm.pdf

    3.2 MBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Attachment 3 - Site Map SanitaryStorm.pdf

    3.2 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • 36C24826Q0936_2.docx

    21 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • 36C24826Q0936_2.docx

    21 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • Attachment 2 - New Vendor Form.pdf

    163 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • Attachment 1 - PWS.docx

    102 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 36C24826Q0936_1.docx

    43 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    J045--Drain and Grease Trap Maintenance

    Notice 48d69082fff5406591fd1bcfbc91f499 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationArchived

    J045--Drain and Grease Trap Maintenance

    Notice 707c762cc8a64dabbc5887ec689358f3 on SAM.gov

  3. 4
    Version 4Combined Synopsis/SolicitationArchived

    J045--Drain and Grease Trap Maintenance

    Notice ebca59a557bd43eca6225961d7526c79 on SAM.gov

  4. 5
    Version 5Combined Synopsis/SolicitationArchived

    J045--Drain and Grease Trap Maintenance

    Notice ed8bb0d9a9194c3fa6213c8bec4c4a2e on SAM.gov

  5. 7
    Version 7Combined Synopsis/SolicitationArchivedCurrent

    J045--Drain and Grease Trap Maintenance

    Notice 6215a4feb53942a7ac1ae08c6c02a054 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C24826Q0936

Archive Date

Sep 15, 2026

Office Address

TAMPA, FL, 33637