GovChime
Notice ID: a017e38b1e5d49e3a483bd6534fb0974Solicitation

Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

Responses closed . Full description on SAM.gov.

Overview

Response deadline
12:00 PM PDT
Posted
June 2, 2022
Notice type
Solicitation
Set-aside
8(a) Set-Aside (FAR 19.8)
NAICS
561621: Security Systems Services (except Locksmiths)
Agency
Department of WarDepartment of the Army

Notice details

Office
W6QM MICC-JB LEWIS-MC CHORD
Place of performance
Joint Base Lewis McChord, 98433
PSC
J012: MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S822R0002
Notice ID
a017e38b1e5d49e3a483bd6534fb0974

Description

The Contractor shall provide all personnel, equipment, tools, materials, supervision, and personnel services necessary to examine, restore, maintain, repair, clean, inspect, and test the following: installed facility fire sprinkler systems, kitchen fire suppression systems, fire pumps, fire pump monitoring devices and related equipment, fire sprinkler monitoring devices, aircraft hangar Aqueous Film Forming Foam (AFFF) systems (to include annual lab testing of the foam concentrate agent), automatic fire alarms, Fire Alarm Control Panels (FACP) including the software and associated devices, (activation, warning and auxiliary), and electrical/electronic components of the systems. The Contractor shall provide testing and programming to facilities with Mass Notification Systems (MNS). The Contractor shall provide updated Computer-Aided Design (CAD) (current year) drawings in a manner that will ensure fire systems serviceability and proper operation. Contractor shall provide a list of major component manufacturers and system components, year of installation as near as can be determined, as well as ITM cycle for sprinkler and suppression systems. Contractor shall submit reports to the Contracting Officers Representative (COR) at JBLM, Washington (WA) and leave a copy of the CAD drawing at the FACP in each building. All work shall comply with and be in accordance with (IAW) the Unified Facilities Criteria (UFC) 3-601-02 Operations and Maintenance: Inspection, Testing, and maintenance of Fire Protections Systems, National Fire Protection Association (NFPA) Standards 10 through 25, 70, 72, 96, JBLM requirements and the manufacturer’s instructions. The Unified Facilities Criteria (UFC) 3-601-02 shall take first precedence over other guidance. Technical Exhibit 1 (TE-1) shows the JBLM and YTC, WA facilities list. Technical Exhibit 2 (TE-2) shows the Kitchen Hood Listing.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Files (27)

  • Solicitation W911S822R0002 Fire Suppression Maintenance and Repair Questions and Responses (1 June 2022).pdf

    125 KBAdded in Solicitation version 6Posted
    Download
  • PWS_Fire Alarm and Suppression ITM_3-19-2022.pdf

    245 KBAdded in Solicitation version 6Posted
    Download
  • W911S822R0002 Amendment 0005 (Conformed Copy).pdf

    1.1 MBAdded in Solicitation version 6Posted
    Download
  • W911S822R0002 Amendment 0005.pdf

    224 KBAdded in Solicitation version 6Posted
    Download
  • PWS_Fire Alarm and Suppression ITM_19 May 2022.pdf

    245 KBAdded in Solicitation version 5Posted
    Download
  • Solicitation W911S822R0002 Fire Suppression Maintenance and Repair Questions and Answers 28 May 2022 V2.pdf

    156 KBAdded in Solicitation version 5Posted
    Download
  • TE-4 Device Count - By Device.pdf

    169 KBAdded in Solicitation version 5Posted
    Download
  • TE-3 Device Count - Number of Devices.pdf

    123 KBAdded in Solicitation version 5Posted
    Download
  • W911S822R0002 AMENDMENT 4 (CONFORMED COPY) v4.pdf

    1.7 MBAdded in Solicitation version 5Posted
    Download
  • W911S822R0002 AMENDMENT 4 v5.pdf

    565 KBAdded in Solicitation version 5Posted
    Download
  • W911S822R0002 Amendment 0003.pdf

    130 KBAdded in Solicitation version 4Posted
    Download
  • W911S822R0002 Amendment 0002.pdf

    130 KBAdded in Solicitation version 3Posted
    Download
  • W911S8-22-R-0002 Amendment 0001.pdf

    130 KBAdded in Solicitation version 2Posted
    Download
  • W911S822R0002 FIRE SUPRESSION.pdf

    901 KBAdded in Solicitation version 1Posted
    Download
  • Attachment 1 - PWS_Fire Alarm and Suppression ITM_28 March 2022.pdf

    260 KBAdded in Solicitation version 1Posted
    Download
  • Attachment 2 - PAST PERFORMANCE SPECIFIC RELEVANT CONTRACTS SHEET.pdf

    56 KBAdded in Solicitation version 1Posted
    Download
  • Attachment 3 - PAST PERFORMANCE QUESTIONAIRE.pdf

    97 KBAdded in Solicitation version 1Posted
    Download
  • Attachment 4 - Consent Letter.pdf

    100 KBAdded in Solicitation version 1Posted
    Download
  • Attachment A - Fire Alarm Inspection Testing form.pdf

    228 KBAdded in Solicitation version 1Posted
    Download
  • Attachment A1 - Fire Alarm Continuation Form.pdf

    91 KBAdded in Solicitation version 1Posted
    Download
  • Attachment B - Kitchen Hood Suppression Form.pdf

    133 KBAdded in Solicitation version 1Posted
    Download
  • Attachment C - Sprinkler System Test Form.pdf

    91 KBAdded in Solicitation version 1Posted
    Download
  • Attachment D - Fire Pump Test Form.pdf

    83 KBAdded in Solicitation version 1Posted
    Download
  • TE-1 2022 JBLM and YTC Facilities Listing.pdf

    244 KBAdded in Solicitation version 1Posted
    Download
  • TE-2 2022 Kitchen Hood Listing.pdf

    104 KBAdded in Solicitation version 1Posted
    Download
  • WD-1 Wage Determination 2015-5539 (REV-20) 15MAR2022.pdf

    56 KBAdded in Solicitation version 1Posted
    Download
  • WD-2 Wage Determination 2015-5543 (REV-16) 15MAR2022.pdf

    55 KBAdded in Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Solicitation

    Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

    Notice 51b99ae7926941f9ad7fd487c97e49ff on SAM.gov

  2. 2
    Version 2Solicitation

    Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

    Notice 3894c8046281498aa14f1dd874469f6a on SAM.gov

  3. 3
    Version 3Solicitation

    Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

    Notice 4d1fc4ed3fbc4c50b08354ab561dd58e on SAM.gov

  4. 4
    Version 4Solicitation

    Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

    Notice 456d5df67ee1440ab33fd9491e8494e4 on SAM.gov

  5. 5
    Version 5Solicitation

    Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

    Notice 3a5cd71a69834f5a84f515bab95e4058 on SAM.gov

  6. 6
    Version 6SolicitationCurrent

    Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

    Notice a017e38b1e5d49e3a483bd6534fb0974 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

W911S822R0002

Archive Date

Jul 30, 2027

Office Address

JOINT BASE LEWIS MCCH, WA, 98433-9500