GovChime
Notice ID: e217a7fed88c47d1abee64d52bd8ad5bSolicitationArchived

Lower Monumental PH HVAC System Upgrade

Archived on October 20, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM PDT
Posted
September 29, 2026
Notice type
Solicitation
Set-aside
No Set aside used
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of WarDepartment of the Army

Notice details

Office
US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION NORTHWESTERN.ENDIST WALLA WALLA.US ARMY ENGINEER DISTRICT WALLA WAL
Place of performance
Kahlotus, Washington, 99335
PSC
Y1KA: CONSTRUCTION OF DAMS
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912EF26RA007
Notice ID
e217a7fed88c47d1abee64d52bd8ad5b

Description

OVERVIEW:

The work is located at the Lower Monumental Dam Powerhouse, Kahlotus, Washington. This solicitation is being issued as a Lowest Price Technically Acceptable (LPTA) Request for Proposal (RFP) and will result in a single firm-fixed price construction contract. This procurement is unrestricted. Competition is open to both large and small business concerns. A small business subcontracting plan is required for large businesses. 100% performance and payment bonds are required for this project. The North American Industry Classification System (NAICS) code for this project is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, and the associated small business size standard is $19,000,000.

System for Award Management (SAM): Offerors must register in SAM at: https://SAM.gov/content/home prior to receiving an award.

SCOPE OF WORK:

The work will provide a modernized HVAC system that will ventilate, heat, and cool the spaces in the powerhouse using river water for both heating and cooling sources. The new system must allow for efficient powerhouse pressurization to reduce smoke and dust ingress into the powerhouse, prolonging equipment life for many assets and providing for good indoor air quality for occupants. The occupied spaces must be provided with sufficient ventilation, comfort heating and comfort cooling. The control room and stairwells must be provided with a system that will be capable of pressurizing those spaces with clean outside air for the exclusion of smoke during a fire event anywhere in the powerhouse in addition to providing sufficient ventilation, comfort heating and comfort cooling. Update the HVAC control system to a modern electronic control system which can be operated from the control room to significantly reduce the effort required to operate the system. Provide permanent access platforms for efficient access to system components for maintenance, such as the maintenance of the dampers in the mixed air plenum and replacement of air filter media in the perceptron room.

THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THE SOLICITATION EITHER BEFORE OR AFTER THE CLOSING DATE. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS PRE-SOLICITATION NOTICE OR ANY FOLLOW-UP INFORMATION REQUEST.

The Contractor will be responsible for establishing and managing an effective Contractor Quality Control (CQC) System that will require the development and submission of a comprehensive project specific CQC Plan for Government acceptance. A CQC System Manager employed by the prime contractor shall be required to be on-site for each shift of the Contractor's operations. The CQC System Manager must possess a minimum of 5-years ‘ relevant experience in a supervisory or management position such as Quality Control Manager, Quality Assurance Manager, or Construction Manager directly involved in the management of construction quality at the project site. In addition, the CQC System Manager shall have completed the course entitled "Construction Quality Management for Contractors" within the last 5-years.

The project will involve the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract.

Please send your proposal by email to: nathan.i.bruce@usace.army.mil

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Files (11)

  • A.02.11 Technical Specifications (Amend 0003).pdf

    36 MBAdded in Solicitation version 10Posted
    Download
  • A.03.09 Drawings (Amend 0003).pdf

    6.5 MBAdded in Solicitation version 10Posted
    Download
  • B.08.03 Solicitation (Amend 0003).pdf

    611 KBAdded in Solicitation version 10Posted
    Download
  • B.08.03 Solicitation (Amend 0002) CONFORMED.pdf

    12 MBAdded in Solicitation version 8Posted
    Download
  • A.03.09 Supplemental Drawings (26RA007).pdf

    519 KBAdded in Solicitation version 7Posted
    Download
  • KTR Site Visit List.pdf

    89 KBAdded in Solicitation version 6Posted
    Download
  • B.08.03 Solicitation (Amend 0001).pdf

    34 MBAdded in Solicitation version 5Posted
    Download
  • A.03.09 Plans (26RA007).pdf

    54 MBAdded in Solicitation version 4Posted
    Download
  • B.08.02 Solicitation (26RA007).pdf

    37 MBAdded in Solicitation version 4Posted
    Download
  • A.03.09 Drawings (26RA007).pdf

    15 MBAdded in Solicitation version 4Posted
    Download
  • A.02.11 Technical Specifications (26RA007).pdf

    4.0 MBAdded in Solicitation version 4Posted
    Download

Lifecycle

  1. 3
    Version 3PresolicitationArchived

    Lower Monumental PH HVAC System Upgrade

    Notice c9600ecb0823497aba76ec0793f7756e on SAM.gov

  2. 4
    Version 4SolicitationArchived

    Type changed from Presolicitation to Solicitation

    Lower Monumental PH HVAC System Upgrade

    Notice 55f654d8e031499ba8b8c0d1ab5c8735 on SAM.gov

  3. 5
    Version 5SolicitationArchived

    Lower Monumental PH HVAC System Upgrade

    Notice ffea0b7178c74524ac11b1410effc7c9 on SAM.gov

  4. 6
    Version 6SolicitationArchived

    Lower Monumental PH HVAC System Upgrade

    Notice b788b429a3124f38a19a33ebcbe6d01c on SAM.gov

  5. 7
    Version 7SolicitationArchived

    Lower Monumental PH HVAC System Upgrade

    Notice 4df3319aa5d74c21ae6c88de753c8f33 on SAM.gov

  6. 8
    Version 8SolicitationArchived

    Lower Monumental PH HVAC System Upgrade

    Notice 447b7bb99a5f4bdf8ee53fb0f9daa777 on SAM.gov

  7. 10
    Version 10SolicitationArchivedCurrent

    Lower Monumental PH HVAC System Upgrade

    Notice e217a7fed88c47d1abee64d52bd8ad5b on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

W912EF26RA007

Archive Date

Oct 20, 2026

Office Address

WALLA WALLA, WA, 99362-1876