GovChime
Notice ID: 7149831c9e1d40bc8eff87d0dcc7311dSolicitationArchived

Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System

Archived on July 8, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM EDT
Posted
June 12, 2026
Notice type
Solicitation
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of CommerceNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

Notice details

Office
DEPT OF COMMERCE NIST
Place of performance
Gaithersburg, Maryland, 20899
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
1333ND26QNB680282
Notice ID
7149831c9e1d40bc8eff87d0dcc7311d

Description

The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest.  This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam.  Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution.  The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter.  The mass of a grating, including a holder is of order 100 g.  The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable.  For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm.  The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.

This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software. 

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (3)

  • Solicitation_1333ND26QNB680282.pdf

    258 KBAdded in Solicitation version 6Posted
    Download
  • PhaseGratingAlignmentStages_STATEMENT OF WORK-Fianl-6-9-26.pdf

    146 KBAdded in Solicitation version 2Posted
    Download
  • Attachment 2- Applicable Provisions and Clauses.pdf

    193 KBAdded in Solicitation version 2Posted
    Download

Lifecycle

  1. 4
    Version 4Sources SoughtArchived

    Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System

    Notice aebf972b7ff44d969c4344832d8192a2 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Type changed from Sources Sought to Solicitation

    Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System

    Notice 674c08068719468b89835f8ab94c7b03 on SAM.gov

  3. 6
    Version 6SolicitationArchivedCurrent

    Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System

    Notice 7149831c9e1d40bc8eff87d0dcc7311d on SAM.gov

  4. 9
    Version 9Award NoticeArchived

    Type changed from Solicitation to Award Notice

    Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System

    Notice 33797c49161f42c3931a2c568741065d on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

1333ND26QNB680282

Archive Date

Jul 8, 2026

Office Address

GAITHERSBURG, MD, 20899