Station Coos Bay Diesel Generator Replacement
Archived on July 3, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM PDT
- Posted
- June 17, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 221112: Fossil Fuel Electric Power Generation
- Agency
- Department of Homeland SecurityUS COAST GUARD
Notice details
- Office
- BASE SEATTLE(00033)
- Place of performance
- Charleston, Oregon, 97420
- Last updated
- Oct 29, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 70Z03326QSEAT0005
- Notice ID
- cf7d5f6152c142d58b0317c1b3e448ac
Description
UPDATE #2: SF-1449 posted.
UPDATE #1: Update to Attachments to include SF 1449, Wage Determination, Provisions and Clauses.
DESCRIPTION OF REQUIREMENT:
The U.S. Coast Guard requires services for removal of existing 40 kW, 120V/240V, three-phase standby diesel generator system and replace it with a new generator system of equivalent specifications. The work includes upgrading the associated Automatic Bypass Transfer Switch (ABT) to match the new generator capacity, ensuring proper exhaust and ventilation, and renewing the fuel system piping and accessories as required. The contractor to provide all personnel, equipment, tools, transportation, supervision, and other items and services necessary to remove and replace existing diesel generator. The Government intends to issue a firm-fixed-price purchase order for this project. The full scope of work and specifications will be included in the solicitation documents.
**Due to access door width, entire generator assembly must be a maximum of 34 ¾” wide to be able to fit into access doorway.
Project Address:
U.S. Coast Guard
Station Coos Bay
63450 Kingfisher Rd
Charleston, OR 97420
United States
This acquisition is set-aside 100% for SMALL BUSINESS.
Where Federal Acquisition Regulation clause language is inconsistent with FAR 13.004, Legal Effect of Quotations, that language is hereby tailored in accordance with FAR 12.302 to be consistent with a request for quotations. This tailoring includes but is not limited to the following: In accordance with FAR 13.004, a quotation is not an offer, and any clause provision to the contrary is hereby modified to be consistent with FAR 13.004. Where the word "offer/offeror" or a derivative of that word appears, it is changed to "quote/quoter" or a derivative of that word.
The associated NAICS code is 221112 (All Other Specialty Trade Contractors).
A site visit will be arranged for interested offerors. All interested offerors must arrive no later than five minutes prior to the start time indicated. Each offeror is highly encouraged to visit the site to provide the government with an accurate and competitive offer but is not required to submit a quote.
Site Visit Date: 06/04/2026
Start Time: 0900
Location: U.S. Coast Guard
Station Coos Bay
63450 Kingfisher Rd
Charleston, OR 97420
United States
Please E-mail Elizabeth Meister elizabeth.a.meister@uscg.mil to RSVP for the site visit no later than 06/04/2026 at 1200 PST.
Any and all questions regarding this solicitation shall be submitted in writing to the Contract Specialist at elizabeth.a.meister@uscg.mil with solicitation RFQ number 70Z03326QSEAT0005 in subject line. Questions regarding the statement of work (SOW) will be forwarded to the technical expert for an accurate response. All responses will be uploaded for an equal and fair solicitation to all interested vendors on solely SAM.gov. No more questions will be answered after 06/11/2026.
All quotes are due by 06/18/2026 0700 (PST) .
SUBMISSION OF QUOTES
Quotes must be submitted electronically to elizabeth.a.meister@uscg.mil by the date and time specified in this solicitation. Incomplete submissions may be considered unresponsive and ineligible for award. A complete submission shall consist of the following parts:
Part 1: Price Quotation
- A completed and signed Standard Form (SF) 1442.
- A detailed Price Breakdown for the total firm-fixed-price. The breakdown must, at a minimum, separate the costs for the following major tasks:
- Demolition & Debris Disposal
- Materials & Installation
- Electrical Work & System Integration
Part 2: Technical Proposal
The Technical Proposal shall not contain any pricing information. It must provide a clear, concise narrative demonstrating the quoter’s understanding of and ability to meet the requirements of the Statement of Work (SOW). The proposal must include:
- Technical Approach: A step-by-step description of how the quoter will perform the work, including mobilization, demolition, installation of footings, gate and fence installation, and electrical hookup.
- Project Schedule: A high-level timeline showing the planned start date, major milestones, and completion date (which must be on or before the required completion date of July 31, 2026.
Submit quotes to the following e-mail address by the offer due date and time zone:
Attn: Elizabeth Meister E-Mail Address: elizabeth.a.meister@uscg.mil with solicitation RFQ number 70Z03326QSEAT0005 in subject line.
It is the government’s intent to make award to the low cost responsible and responsive offeror who provides the most advantageous, reasonable, and negotiable offer to the government. Under FAR 4.1103 prospective contractor shall be registered in System Award Management (SAM) prior to award. Failure for contractor to be registered in SAM shall result in Contracting Officer to proceed with next successful registered offeror. Website: www.sam.gov
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (5)
- Download
SF1449.pdf
175 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
Provisions and Clauses.pdf
19 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
Wage Determination.txt
43 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
Emergency Generator Room.jpg
874 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
STA Coos Bay_Station Generator_SCOPE OF WORK.pdf
3.3 MBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 1Version 1Combined Synopsis/SolicitationArchived
Station Coos Bay Diesel Generator Replacement
- 2Version 2Combined Synopsis/SolicitationArchived
Station Coos Bay Diesel Generator Replacement
- 3Version 3Combined Synopsis/SolicitationArchived
Station Coos Bay Diesel Generator Replacement
- 5Version 5Combined Synopsis/SolicitationArchivedCurrent
Station Coos Bay Diesel Generator Replacement
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The United States Embassy Annex in Pretoria requires professional services to perform Planned Maintenance and Inspection services of the facility’s Low Voltage Diesel Standby Generator systems. The quote reference number: PR16188108 The following documents are attached to this email and need to be signed when submitting your quotations: - The SCOPE OF WORK. - US Government Clauses Quotations: Firm fixed pricing is to be quoted. Quotes to be completed on the company letterhead, indicating the company’s address, contact details and name and email of the contact person. No alterations or pricing changes will be accepted after the Quotation deadline. Please quote in South African Rand (ZAR) Closing date and time for receiving quotes is 17:00, September 8, 2026. Kindly be advised that NO late quotes will be accepted. Quotes must be sent via email to: Pretoria_contracting_office-dl@state.gov U.S. Embassy Payment terms: - Note that NO DEPOSIT payments will be authorized. - The Embassy issues only fixed priced contracts; therefore, you must confirm that your prices will remain fixed. The US Embassy will make no provision for fluctuations in price or exchange rates after the order has been placed. If your price is dependent on these fluctuations, you MUST make provision for possible increases in your quoted price. - EFT – Payment will be made within 30 calendar days after delivery of services AND receipt of invoice, whichever is later. Kindly be advised that as a Diplomatic Mission we represent the U.S. Government and are unable to sign any legal documents, including credit applications and T’s & Cs. By submitting a quote, you waiver any such requirement. The successful offeror will be required to accept: FAR and DOSAR Clauses: The attached FAR and DOSAR clauses form part of this contract. Please see the attached qualifications and evaluation factors | 58% | Solicitation | 09/08/2026 |
Request for Proposal Generator Replacement at CMR, Jl. Taman Surapati #3, Menteng, Jakarta Pusat Enclosed is a Request for Proposal (RFP) for Generator Replacement at CMR, Jl. Taman Surapati #3, Menteng, Jakarta Pusat. If you would like to submit a quotation, follow the instructions in Section J of the solicitation, complete the required portions of the attached document, and submit it to the address shown on the Standard Form that follows this letter | 54% | Solicitation | 11/23/2026 |
Emergency Diesel Mobil Generator 320 kW / 1800 RPM, including Tandem Axle. | 47% | Combined Synopsis | 03/09/2026 |
COMBINED SYNOPSIS/SOLICITATION NOTICE: Requirement Title: Rental of one (1) Diesel Generator Solicitation Number: N3904026Q3082 Response Deadline: 12/03/2025 @1200 EST POC: Gordon Roberts III (gordon.j.roberts1@navy.mil); 207-451-7119 Portsmouth Naval Shipyard, Kittery, ME GENERAL INFORMATION: 1. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued Paper copies of this solicitation will not be available. This combined synopsis/solicitation SHALL be posted on SAM.gov. 2. This solicitation documents and incorporates provisions and clauses in effect through FAC 2025-05 and DFARS Change Notice 2025-1024. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses: https://www.acquisition.gov/browse/index/far and http://www.acq.osd.mil/dpap/dars/change_notices.html. 3. This solicitation is being issues as a(n): Request For Quotation (RFQ) 4. This acquisition is for: Total Small Business Set Aside 5. North American Industry Classification System Code (NAICS): 532490 “Other Commercial and Industrial Machinery and Equipment Rental and Leasing” 6. The size standard is: 40 Millions of Dollars REQUIREMENT INFORMATION: The Portsmouth Naval Shipyard requests responses from sources capable of providing the following: Rental of One (1) Diesel Generator Period of Performance: 01/05/2026 – 02/15/2026 (6 Weeks) Option Period of Performance: 02/16/2026 – 03/01/2026 (2 Weeks) Place of Performance: Naval Station Norfolk, Norfolk VA METHOD OF PROPOSAL SUBMISSION: Offers shall be emailed. All responsible sources may submit a quote which shall be considered by the agency. System for Award Management (SAM): Vendors must be registered in the SAM database to be considered for award. Registration is free and can be completed on-line at http://www.sam.gov/. All quotes shall include a completed technical specification sheet upon proposal. Amendment-01 of this solicitation is to update a minor typo in the statement of work. | 44% | Combined Synopsis | 12/03/2025 |
This is a combined synopsis/solicitation for commercial items prepared in accordance with the FAR Overhaul Part 12 and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Offers are being requested, and a separate written solicitation will not be issued. Solicitation 70Z08427P21001B00 is issued as a Request for Quotation (RFQ) This solicitation incorporates provisions and clauses by reference. Full text of provisions and clauses may be accessed electronically at www.acquisition.gov. This acquisition is Brand Name Mandatory. Brand name part is mandatory to be considered for award. The U.S. Coast Guard, Surface Forces Logistics Center (SFLC) intends to award a Firm Fixed Price Purchase Order. No down payments or advanced payments will be made to the awarded vendor. Award will be made on a Best Value Basis as result of this synopsis/solicitation. All responsible sources may submit a quotation, which if timely received, shall be considered by this agency. Best Value will be evaluated by who meets all technical requirements, who meets our required time frame and by price. All quotes shall be emailed to Courtney Gustin via Courtney.C.Gustin@uscg.mil and shall be received no later than 03 NOV 26 at 10:00 am (eastern). All emails quotes shall have 70Z08427P21001B00 in subject of email. Item 1) NSN: 6130-01-543-0864 POWER SUPPLY, UNINTERRUPTIBLE HIPRESS RO PUMP & 7.5 HP MOTOR EACH PUMP MUST BE INDIVIDUALLY PACKAGED AND MARKED MFG: SCHNEIDER ELECTRIC IT CORPORATION PN: SUA1500X93 QTY: 18 EA APC SMART-UPS 1500VA USB 120V SHIPBOARD SMART UPS SIGNALLING RS-232 CABLE, USB CABLE, USER MANUAL APC SMART-UPS 1500VA. OUTPUT POWER CAPACITY: 1440 VA, OUTPUT POWER: 980 W SURGE ENERGY RATING: 320 J CABLE LENGTH: 1.83 M TYPICAL BACKUP TIME AT HALF LOAD: 23.9 MIN, TYPICAL BACKUP TIME AT FULL LOAD: 6.7 MIN REPLACEMENT BATTERY CARTRIDGE: RBC7 COLOUR OF PRODUCT: BLACK. NOISE LEVEL: 45 DB NOTE: ALL OF THESE ITEMS MUST BE INDIVIDUALLY PACKAGED, PROTECTED AND MARKED ACCORDING TO MIL-STD-2073-1E W/CHANGE 1 7 JANUARY 2011 MILITARY PACKAGING; MIL-PRF-81705E_AMENDMENT-1 BARRIER MATERIALS, FLEXIBLE, ELECTROSTATIC DISCHARGE PROTECTIVE, HEAT-SEALABLE (IF REQUIRED); AND MIL-STD-129R MILITARY MARKING FOR SHIPMENT AND STORAGE (MIL-STD-129R, SECTION 5, PAGE 22 OF SPEC). COPIES INCLUDED WITH THIS SAPS PACKAGE. EACH UNIT TO HAVE ELECTROSTATIC PROTECTION IAW TYPE III, CLASS I OF MIL-PRF-81705E_AMENDMENT-1 BARRIER MATERIALS, FLEXIBLE, ELECTROSTATIC DISCHARGE PROTECTIVE, HEAT-SEALABLE; IF REQUIRED. EACH ITEM TO BE INDIVIDUALLY PACKAGED IAW THE FOLLOWING: MIL-STD-2073-1E W/CHANGE 17 JANUARY 2011, METHOD 10. ASTM-D-3951-10 PACKING, COMMERCIAL (IF SPECIFICALLY AUTHORIZED BY THE GOVERNMENT). EACH ITEM TO BE INDIVIDUALLY MARKED IAW THE FOLLOWING: MIL-STD-129R 14 FEB 2014 MARKING FOR SHIPMENT AND STORAGE. BAR CODING REQUIRED, IF CAPABLE, TO COMPLY WITH THE FOLLOWING: MIL-STD-129R 14 FEB 2014 MILITARY MARKING FOR SHIPMENT AND STORAGE. SEE SECTION 5, PAGE 22 OF THIS SPECIFICATION FOR IDENTIFICATION LINEAR (CODE 39) AND 2D (PDF417) BAR CODE MARKINGS AND LOCATIONS. BAR CODING REQUIRED, IF CAPABLE, TO COMPLY WITH THE FOLLOWING: MIL-STD-129PCH4 MILITARY MARKING. SEE 4.4, PAGE 47 OF THIS SPECIFICATION FOR IDENTIFICATION LINEAR (CODE 39) AND 2D (PDF417) BAR CODE MARKINGS AND LOCATIONS. REQUIRED DELIVERY DATE: 30 DECEMBER 2026 SHIP-FOB DESTINATION TO: USCG SFLC RECEIVING ROOM – BLDG. 88 2401 HAWKINS POINT ROAD BALTIMORE, MD 21226 FAR CLAUSES: This order is subject to but not limited to the following Federal Acquisition Regulations: 52.204-19 Incorporation by Reference of Representations and Certifications. 52.212-1 Instructions to Offerors—Commercial Products and Commercial Services. 52.212-2 Evaluation-Commercial Products and Commercial Services. 52.212-4 Contracts Terms and Conditions. 52.219-6 Notice of Total Small Business Set-Aside. 52.222-50 Combat Trafficking in Persons 52.222-90 Addressing DEI Discrimination by Federal Contractors. 52-225-1 Buy American-Supplies 52.226-8 Encouraging Contractor Policies to Ban Text Messaging While Driving 52.247-34 F.O.B. Destination | 44% | Combined Synopsis | 11/03/2026 |
Additional Details
Solicitation Number
70Z03326QSEAT0005
Archive Date
Jul 3, 2026
Office Address
SEATTLE, WA, 98134