Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
Archived on July 8, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:00 AM EDT
- Posted
- June 12, 2026
- Notice type
- Solicitation
- NAICS
- 334516: Analytical Laboratory Instrument Manufacturing
- Agency
- Department of CommerceNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
Notice details
- Office
- DEPT OF COMMERCE NIST
- Place of performance
- Gaithersburg, Maryland, 20899
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 1333ND26QNB680282
- Notice ID
- 7149831c9e1d40bc8eff87d0dcc7311d
Description
The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.
This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (3)
- Download
Solicitation_1333ND26QNB680282.pdf
258 KBAdded in Solicitation version 6Posted - Download
PhaseGratingAlignmentStages_STATEMENT OF WORK-Fianl-6-9-26.pdf
146 KBAdded in Solicitation version 2Posted - Download
Attachment 2- Applicable Provisions and Clauses.pdf
193 KBAdded in Solicitation version 2Posted
Lifecycle
- 4Version 4Sources SoughtArchived
Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
- 2Version 2SolicitationArchived
Type changed from Sources Sought to Solicitation
Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
- 6Version 6SolicitationArchivedCurrent
Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
- 9Version 9Award NoticeArchived
Type changed from Solicitation to Award Notice
Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
1333ND26QNB680282
Archive Date
Jul 8, 2026
Office Address
GAITHERSBURG, MD, 20899