Notice ID: 5590cd4d3bd64f0f91672968afbd8cb8Award NoticeAwardedArchived
AUTOCLAVES WITH PRITNERS
Awarded on June 11, 2026. Full description on SAM.gov.
Awarded tounder 75H71126P00093 (source: SAM.gov award notice)• $30.8K
Overview
- Posted
- June 11, 2026
- Notice type
- Award Notice
- Set-aside
- Buy Indian Set-Aside (specific to Department of Health and Human Services, Indian Health Services)
- NAICS
- 339114: Dental Equipment and Supplies Manufacturing
- Agency
- Department of Health and Human ServicesINDIAN HEALTH SERVICE
Notice details
- Office
- INDIAN HEALTH SERVICE
- Place of performance
- Clinton, Oklahoma, 73601
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
- Award date
- Jun 11, 2026
- Award amount (SAM.gov award notice)
- $30.8K
Identifiers
- Solicitation number
- 75H71126P00093
- Notice ID
- 5590cd4d3bd64f0f91672968afbd8cb8
- Award number (PIID)
- 75H71126P00093
Description
AWARD NOTICE
Award Overview
Award Number
75H71126P00093
Award Amount (SAM.gov award notice)
$30.8K
Award Date
Jun 11, 2026
Awardee
Awardee UEI
FCDMHYJUCEV7
Awardee CAGE Code
9CBG4
Awardee Address
Oklahoma City, OK 73106, UNITED STATES
Original Solicitation
Notice ID: 5590cd4d3bd64f0f91672968afbd8cb8
Posted Date: Jun 11, 2026
Original Response Deadline: Not specified
Contacts
Contracting Officer
Primary Contact
Documents
Files (3)
- Download
QUESTIONS AND ANSWERS.docx
14 KBAdded in Combined Synopsis/Solicitation version 4Posted - Download
IHS IEE Representation Form_Jan 2022_508 Compliant.pdf
129 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
COMBINED SYNOPSIS SOLICITATION.pdf
189 KBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 3Version 3Combined Synopsis/SolicitationArchived
AUTOCLAVES WITH PRITNERS
- 5Version 5Award NoticeArchivedCurrent
Type changed from Combined Synopsis/Solicitation to Award Notice
AUTOCLAVES WITH PRITNERS
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The Department of Veterans Affairs Network Contracting Office (NCO) 19, Oklahoma VA Health Care System is issuing this Sources Sought Notice on behalf of the Oklahoma VA Health Care System located at 921 NE 13th St, Oklahoma City, OK 73104 as a means of conducting market research to identify DOMESTIC MANUFACTURERS having an interest in, and the resources to support this requirement for Dental Instruments with SALIENT CHARACTERISTICS EQUIVALENT TO the following Dentsply equipment: CEREC Primemill US Suction Unit (Dry Milling) 120VAC DS Core care Scanner AC Annual DS Core Care Primemill Annual DS Core Care Speedfire Annual DS Powerup Labor Scanner AC DS Powerup Labor Mill Annual DS Powerup Labor Oven Annual SpeedFire Oven Software 5.2 Software License Stick Gen2 Primescan Scanning speed of 3000 images per second. 3D image conversion speed 1000 images per second. Autoclave or disposable tips. Scanning accuracy of 6.9 ± 0.9 µm. Ethernet or Wi-Fi based connection Suction unit The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 339114 Dental Equipment and Supplies Manufacturing. This is a request for information and sources only, which may or may not lead to a future solicitation! This is not a solicitation. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Objective: The Oklahoma City VA Health Care System (OKC VAHCS) is seeking DOMESTIC ALTERNATIVES to the Dentsply Sirona Cerec Primescan, Primemill, Speedfire oven, Suction unit and sustainment, for the opening of the new Norman, OK Dental Clinic. This procurement will ultimately result in a new, firm-fixed price contract. The OKC VAHCS is seeking ONLY domestically manufactured products to fulfill this requirement, pursuant to the Buy American Act. SALIENT CHARACTERISTICS requested for the desired Dental Instruments are as follows: CEREC PrimeMill US Suction Unit (Dry Milling) 120VAC Sustainment Milling Unit only 3years Sustainment Extension year 4 Sustainment Extension year 5 Primescan Intraoral Scan Data Transmission Digital workflow Speedfire Functionality Combine the process of sintering and glazing Maximum heating rate of 300 degree Celsius No preheating or holding temperatures required Must work with Primescan scanner Performance Chararcteristics Type of protection against electric shock: Protection Class I device Degree of protection against ingress of water: Ordinary device (without protection against ingress of water) Setup: Indoors in dry area Operating altitude: 2000 m above sea level with a temperature range of 5°C to 35°C (41°F to 95°F) Operating altitude: 2000 m - 3000 m above sea level with a temperature range 5°C to 30°C (41°F to 86°F) Relative humidity max. 80% Pollution degree: 2 Mode of operation Continuous operation Dimensions of unit (W x H x D in mm): 250 x 425 x 425 Dimensions of packaged unit (W x H x D in mm): 400 x 600 x 500 Furnace chamber: Diameter 38 mm x 20 mm height Maximum sintering temperature: 1600°C (2912°F) Approx. weight without packaging: 21 kg Approx. weight including packaging: 30 kg Rated line voltage: AC 100 V - 240 V Rated power frequency: 50/60Hz Admissible line voltage fluctuations: ±10% of nominal voltage Power consumption: max. 1200 W Interfaces: 2x USB 2.0 1x LAN (RJ45) WLAN (optional via WLAN USB dongle) LAN switch (optional). BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and multiple awards MAY be made. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. SUBMISSION INSTRUCTIONS: If your organization can provide these services and is interested in this opportunity, please respond to Shanta Harrison, Contract Specialist, Department of Veterans Affairs, NCO 19 via e-mail at Shanta.Harrison@va.gov with a statement describing your capabilities. The capability statement shall include a primary point of contact, complete mailing address, telephone number, email address, state the company s business size status and should address this specific requirement, with appropriate documentation supporting claims of organizational and staff capability. Please be as thorough as possible in your submission, and include information on any multiple award schedule contracts your company holds. Requests for copies of a solicitation will not be honored or acknowledged. The deadline for responses is Wednesday, October 21, 2026 at 4:00 PM mountain time. | - | Market Research | 10/21/2026 |
Attached responses to answers to questions from Industry. Please see the attached Buy America Certificate. See Statement of Work attached (SOW) . | - | Solicitation | 11/06/2026 |
This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with Part 12. This announcement constitutes the only solicitation. Offers are being requested, and a separate written solicitation will not be issued. Solicitation number 36C24W26Q0233 is issued as a Request for Quotation (RFQ) for Blanket Warmer Systems. This acquisition is set aside for small business concerns. This solicitation incorporates provisions and clauses by reference. PLEASE READ ALL ATTACHMENTS | - | Combined Synopsis | 08/18/2026 |
Amendment 1 posted to reopen solicitation and set new close 11/06/2026 @ 2:00 EST. Dental/Denture - equipment | - | Combined Synopsis | 11/06/2026 |
SOURCES SOUGHT FOR DENTAL LABORATORY SERVICES FOR THE BEMIDJI AREA SERVICE UNITS OF RED LAKE AND CASS LAKE IHS IAW THE ATTACHED STATEMENT OF WORK. THIS IS 100% IEE CERTIFICATION MUST BE SUBMITTED | - | Market Research | 11/16/2026 |
Additional Details
Solicitation Number
75H71126P00093
Archive Date
Jun 26, 2026
Office Address
OKLAHOMA CITY, OK, 73114