GovChime
Notice ID: 366fb8a312ed4d79a93ff9cbdd580107Award NoticeAwardedArchived

J056--Walls/Flooring/Ceiling Corrective Services

Awarded on February 20, 2026. Full description on SAM.gov.

Awarded tounder 36C25626P0385 (source: SAM.gov award notice)• $298.0K

Overview

Posted
February 20, 2026
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
561210: Facilities Support Services
Agency
Department of Veterans Affairs

Notice details

Office
256-NETWORK CONTRACT OFFICE 16 (36C256)
Place of performance
Jackson, Mississippi, 39216
Last updated
Nov 2, 2026
First published
Last updated on SAM.gov
Award date
Feb 20, 2026
Award amount (SAM.gov award notice)
$298.0K

Identifiers

Solicitation number
36C25626Q0322
Notice ID
366fb8a312ed4d79a93ff9cbdd580107
Award number (PIID)
36C25626P0385

Description

This is an official notice that the award for 36C25626P0385, under the solicitation 36C25625Q0762 on SAM.gov, has been cancelled. This decision comes after careful consideration and review of the circumstances surrounding the award. Affected entities and individuals should take note that all activities and expenditures covered under this award must cease immediately. Any further information regarding the next steps and potential re-issuance of this award will be provided through SAM.gov and direct communications. We apologize for any inconvenience this may cause and appreciate your understanding.

Full description on SAM.gov

Award Overview

Award Number

36C25626P0385

Award Amount (SAM.gov award notice)

$298.0K

Award Date

Feb 20, 2026

Awardee

Awardee UEI

PYLAT7QP8P41

Awardee CAGE Code

98MZ5

Awardee Address

SAINT LOUIS, MO 63121, MO

Original Solicitation

Notice ID: 366fb8a312ed4d79a93ff9cbdd580107

Posted Date: Feb 20, 2026

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

Caleb Parker
Contract Specialist

Documents

Files (2)

  • 36C25626P0385_1.docx

    22 KBAdded in Award Notice version 6Posted
    Download
  • 36C25626P0385-.docx

    23 KBAdded in Special Notice version 4Posted
    Download

Lifecycle

  1. 4
    Version 4Special NoticeArchived

    J056--Walls/Flooring/Ceiling Corrective Services

    Notice 7db6961723de45738bbd737448ca474f on SAM.gov

  2. 6
    Version 6Award NoticeArchivedCurrent

    Type changed from Special Notice to Award Notice

    J056--Walls/Flooring/Ceiling Corrective Services

    Notice 366fb8a312ed4d79a93ff9cbdd580107 on SAM.gov

Other notices for this solicitation

  1. SolicitationRelated noticeJan 21, 2026

    Walls/Flooring/Ceiling Corrective Services

    Notice a41f6102fccd41e3b1eac6bfa5e9ddaf on SAM.gov

  2. SolicitationRelated noticeJan 27, 2026

    Walls/Flooring/Ceiling Corrective Services

    Notice 178be76c2624413393de47015346177b on SAM.gov

  3. SolicitationRelated noticeJan 28, 2026

    Walls/Flooring/Ceiling Corrective Services

    Notice f2227ef67f0a4461b851acdb4bec9874 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
-AwardedOpen
SF 30 CONTINUATION SHEET AMENDMENT 0002 Solicitation No.: 36C25627Q0022 Project: B170 Courtyard Window Re Caulk CAVHS Purpose of Amendment The purpose of this amendment is to provide the Government s responses to vendor questions submitted prior to the deadline. The following Questions & Answers are hereby incorporated into the solicitation. These clarifications do not change the scope of work unless explicitly stated. Only the Contracting Officer may authorize changes per FAR 52.212 4(c). SECTION: QUESTIONS & ANSWERS General Administrative Items Q1. Will the Government confirm that offers should be submitted via email to andrew.misfeldt@va.gov? A1. Yes. Submit one consolidated PDF ( 10MB), font Arial 11, in accordance with the solicitation instructions. Q2. Are there page limitations? A2. No page limits apply. The file-size limit of 10MB governs. Q3. Which form must be submitted SF 1449 or SF 1442? A3. Offerors shall submit a signed SF 1449. SF 1442 is not required. Evaluation Factors Q4. Please confirm the evaluation factors. A4. Evaluation consists of: Factor I Approach & Quality Management Factor II Professional Qualifications & Specialized Experience Factor III Past Performance Factor IV Price Factors I III are equal in importance and collectively approximately equal to Price. Q5. Does managing one subcontractor satisfy Past Performance requirements? A5. Yes, provided the offeror served as the prime contractor. Site Visit, Access, & Logistics Q6. Will there be a site visit? A6. A site visit was held on October 14, 2026. No additional site visits will be conducted. Q7. Please confirm logistical restrictions. A7. Approximate curtainwall height is 50 ft (verify independently). Elevator weight limit is 4,000 lbs. Courtyard door widths are 36 58 . Quiet hours are 2 3 PM and 10 PM 5 AM. Coordinate courtyard occupation with nursing staff. Q8. Are badges required? A8. Not for courtyard work during business hours. Badges are required for roof access. Delays caused by incomplete contractor submissions are not excusable delays. Scope Clarifications Q9. Does work occur along the entire curtainwall or only at leak locations? A9. Work shall occur along the entire curtainwall interface within Courtyards 1B and 1C to provide a continuous and complete seal. Q10. Should the entire length be repaired for a uniform seal? A10. Yes. Q11. Are cover caps replaced everywhere? A11. No. Replace only caps that are missing or cannot be reattached. Q12. Are other courtyard walls included? A12. No. Only the curtainwall/TPO/wall interface is included unless otherwise directed by the CO. Q13. Will the Government provide as builts or record drawings? A13. No. They are not available. Q14. Will the Government provide quantities? A14. No. Offerors must determine all quantities during the site visit. These measurements are binding for proposal purposes. Q15. Is full perimeter window caulking included? A15. No. Only the interfaces described in the SOW apply. Q16. Clarify termination bar installation. A16. Install the bar above the cant strip to secure the existing TPO using fasteners compatible with the substrate. Q17. Clarify face cap/flashing quantities. A17. Approximately 14 vertical caps have slid; one horizontal cap is missing; two require replacement. Remove flashing attached to the ground level base face cap. Offerors must verify all quantities. Q18. Will the awning require removal? A18. Not anticipated. Do not include awning removal unless CO directed. Q19. How many pavers must be moved and how should they be stored? A19. Approximately 70 pavers must be moved. Store in the courtyard, stacking no more than six high. Specifications, Submittals, & Warranty Q20. Which parts of VA 07 54 23 apply? A20. Membrane accessory materials and compatibility requirements apply. VA 07 92 00 applies to sealant products. Where requirements conflict, the more stringent governs. Q21. Confirm applicability of installer approvals, warranty, submittals, and pre installation meeting. A21. Manufacturer-approved roofing installer: Not required. Sealant warranty: 10-year manufacturer warranty required. Submittals: Required for sealants and termination materials showing compatibility. Pre installation meeting: Required prior to NTP; the 30 day PoP begins after NTP issuance. Q22. Provide TPO manufacturer or warranty info. A22. Unknown. Contractor is not responsible for maintaining prior warranties and shall ensure compatibility of materials. Schedule & Period of Performance Q23. Will NTP be flexible due to temperature/weather? A23. Yes. NTP may be adjusted as appropriate. Excusable delays are handled per FAR 52.212 4(f). Q24. Are background checks/PIV issuance included in the PoP? A24. Yes. Badges only required for roof access. Delays arising from incomplete contractor submissions are not excusable. Q25. Will water spray or infiltration testing be required? A25. No. Optional testing may be performed at the contractor s cost unless CO directed. Q26. Anticipated award/NTP date? A26. Award is anticipated on or around November 1, 2026 (subject to change). Schedule adjustments for weather may be considered if CO approved. Labor Standards, Set Aside, Subcontracting, & Bonds Q27. Which wage determination applies? A27. Davis Bacon Wage Determination AR20260032 applies. Q28. Will the contract be issued under DBRA only? A28. Yes. Any SCLS references are not applicable and will be conformed administratively. Q29. Which limitations on subcontracting apply? A29. Construction limitations apply. For special trade construction, no more than 75% (excluding materials) may be subcontracted to non similarly situated entities. LOS certification must be submitted. Q30. Are performance and payment bonds required? A30. No. Bonds are not required under this solicitation unless added by future amendment. Q31. Confirm SDVOSB status requirements. A31. This is a total SDVOSB set aside. Offerors must be certified in the SBA database at time of offer and award. Materials & Trades Q32. Will brake metal caps be accepted if originals are unavailable? A32. Yes, if they closely match existing caps and are approved before installation. Q33. Is a glazing contractor required? A33. No. Quantities & Pricing Basis Q34. Can VA provide LF quantities of termination bar or number of caps? A34. No. Offerors must determine quantities during the site visit. Q35. Should offerors price awning removal? A35. No. Do not include awning removal unless CO directed. Unforeseen/Differing Site Conditions Q36. How will additional TPO damage discovered during work be handled? A36. Repairs beyond the defined scope may only be performed if directed in writing by the Contracting Officer. Entitlement will be determined at that time. Q37. Are leaks associated with recent renovations? A37. No. Leaks have been occurring since the membrane was installed. Attachments Q38. Are photos/figures available? A38. Yes. Figures 1 6 included for reference only. Offerors must verify all conditions independently. Figure 1. Curtainwall Above GE101A and GE10B Figure 2. Curtainwall Above GF100 Figure 3. Missing Horizontal window base cap Figure 4. Flashing attached to horizontal window face cap Figure 5. TPO membrane beneath windows Figure 6. Metal Awning
-Solicitation10/29/2026
White City Boiler Inspection Services Solicitation Number 36C26026Q0977 Due to a large number of questions, as the CO, I am extending the offer due date to 11/13/2026. I will allow questions for 1 week starting on 11/02/2026 – 11/06/2026. This Solicitation (36C26026Q0977) will remain an SDVOSB 100% total set aside. If you have any questions please email: Jeremiah.Middleton2@VA.GOV ________________________________________________________________________________________________________ The objective of this solicitation is to provide VA Southern Oregon Rehabilitation Center and Clinics (VA SORCC) with Boiler Plant Inspection Services. The period of performance shall be as follows: Base Year: 12/1/2026 to 11/30/2027 Option Year 1: 12/1/2027 to 11/30/2028 Option Year 2: 12/1/2028 to 11/30/2029 Option Year 3: 12/1/2029 to 11/30/2030 Option Year 4: 12/1/2030 to 11/30/2031 Background: The VA SORCC has three Power boilers, each rated at 250HP operating at low pressure (<15 psi), gas and oiled fired. Yearly state inspections are required on all three boilers, one deaerator/ feed water tank (DA/FWT), one heat recovery tank (HRT), one condensate storage tank (CST), and one bottom blow tank (BBT). ******Option year three will require the yearly state inspections on all three boilers, one deaerator/ feed water tank, one heat recovery tank, one condensate tank, and one bottom blow tank and have a Non-Destructive Test (NDT), And a Life Expectancy report performed on the DA/FWT ******. A NEW PWS HAS BEEN UPLOADED TO SAM.GOV ON 11/1/2026 A NEW 1449 SOLICITATION HAS BEEN UPLOADED TO SAM.GOV ON 11/1/2026 Amendment 0002 is no longer valid due to a new PWS being issued on this solicitation. Before you send any questions please make sure you have read all of the amendments, PWS and 1449.
-Solicitation11/13/2026
Request for Quote: 36C24727Q0073 The Department of Veterans Affairs, Columbia Healthcare System, WJB Dorn VA Medical Center, requires one-time chiller tube cleaning services for two chillers located in the facility s Chiller Plant. The Contractor shall provide all labor, supervision, travel, equipment, tools, supplies, materials, and incidental services necessary to complete the work described in this Statement of Work/Performance Work Statement (SOW/PWS). 1.2 Facility Background The WJB Dorn VA Medical Center is a 216-bed medical facility providing acute medical, surgical, psychiatric, and long-term care services. The facility is located in Columbia, South Carolina, and provides primary, secondary, and selected tertiary care.
-Combined Synopsis11/27/2026
Amendment to Combined Synopsis-Solicitation for Commercial Products and Commercial Services RFQ: 36C24127Q0016 Water Management Program and Chemical Testing Effective Date: 01/15/2026 Revision: 03 This is a combined synopsis/solicitation Amendment 0001 with a 100% SDVOSB/VOSB set-aside for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is a request for quotations (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. The associated North American Industrial Classification System (NAICS) code for this procurement is 561210 with a small business size standard of $19 million. The Department of Veterans Affairs Network Contracting Office 01 is seeking to purchase the supplies or services described in the following Statement of Work. This is a combined synopsis/solicitation Amendment 0001 notice synopsizing an upcoming RFQ solicitation to satisfy the requirements of RFO FAR 5.2 and RFO FAR 5.3. All interested parties should register via SAM.gov interested vendors list. It is the responsibility of the offeror to monitor and download amendments from SAM.gov Contract Opportunities, which may be issued to this solicitation. In accordance with RFO FAR 52.204-7, RFO FAR 2.101, and VAAR 802.101, prospective firms must be registered in SAM (www.sam.gov), and in SBA VetCert (Veteran Small Business Certification (sba.gov)) databases prior to award. ((Note: In accordance with Public Law 109-461, 38 USC 8127, and NDAA 2021, all vendors claiming Small Business status in accordance with the Veteran's First Contracting Program must be VERIFIED by the Small Business Administration (SBA)). Also, to qualify for a VA contract, vendors must be vendorized by completing Form 10091 at URL Â https://www.cep.fsc.va.gov/ . The purpose of this solicitation amendment is to: 1) Add Questions and Answers document. 2) Update SOW 3) Extend Solicitation due date until 11/06/2026 at 12:00 PM EST. Offerors should carefully follow instructions included in 52.212-1 and for evaluation criteria specified in FAR clause 52.212-2. Pricing should be on page 2. Interested persons may contact the Contract Specialist via email at pamela.parham3@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer
-Combined Synopsis11/06/2026

Additional Details

Solicitation Number

36C25626Q0322

Archive Date

Apr 21, 2026

Office Address