GovChime
Notice ID: 235af171f5f14c0c8ea0ec5da3dbe948Special NoticeArchived

H946--Intent to sole source

Archived on October 21, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
1:00 PM EDT
Posted
September 22, 2026
Notice type
Special Notice
NAICS
221310: Water Supply and Irrigation Systems
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25026Q0666
Notice ID
235af171f5f14c0c8ea0ec5da3dbe948

Description

Special Notice Special Notice Page 5 of 5 Special Notice *= Required Field Special Notice Page 1 of 2 Notice of Intent to Sole Source LOCATION: Department of Veterans Affairs (VA), VISN 10 Dayton VA Medical Center 4100 W. Third Street Dayton, OH 45428 SUBJECT: Intent to Sole Source Water service and maintenance, post-secondary potable water disinfection and testing, and ancillary water systems. NOTICE NUMBER: 36C25026Q0666 PSC CODE: H946 Other Quality Contril, Testing, and Inspection Water Purification and Sewage Treatment Equipment NAICS CODE: 221310 Water Supply and Irrigation Systems Small Business Size Standard: $41 Million DESCRIPTION OF REQUIREMENT Service and Maintenance of 15 Sanipur and 17 Buckman water systems and 45 ice machines in all to include all labor, materials, parts, supervision for current systems in place. PLACE OF PERFORMANCE Department of Veterans Affairs (VA), VISN 10 Dayton VA Medical Center 4100 W. Third Street Dayton, OH 45428 PERIOD OF PERFORMANCE Base plus four. ANTICIPATED CONTRACT TYPE Firm Fixed Price (FFP) ESTIMATED MAGNITUDE Base year will be estimated $1,350,483.24 AUTHORITY This acquisition is being conducted under FAR 6.103-1 Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements JUSTIFICATION SUMMARY Based on market research and historical technical findings, Rochester Midland Corporation is the only responsible source with the unique qualifications necessary to provide all labor, materials, parts and supervision necessary to protect all water systems for domestic hot and cold water, steam, chillers, cooling towers, boilers, ice machines, reverse osmosis systems, and hydronic heating and chilled water systems. Rochester Midland Corporation is the only authorized Sanipur and Buckman Laboratories, Inc. distributor and service provider for the existing equipment for the State of Ohio. Rochester Midland Corporation possesses: Site specific analytical history. Proficient in working with a wide range of equipment and systems, including domestic hot and cold-water systems, steam systems, chillers, cooling towers, boilers, ice machines, reverse osmosis systems, and hydronic heating and chilled water systems. Immediate availability to perform the work without operational disruption. THIS IS NOT A REQUEST FOR COMPETITIVE QUOTES However, any firm believing it can fully meet this requirement may submit a capability statement demonstrating clear and convincing evidence of its ability to perform the work within the required timeframe. RESPONSE INSTRUCTIONS Submit capability statements no later than 1:00PM on June 20, 2026, to: Ronald T. Heidemann Contracting Officer Email: ronald.heidemann@va.gov Submissions must include: UEI number and active SAM.gov status Business size for NAICS 221310 Technical capability supporting all required tasks Authorization to work on Sanipur and Buckman water equipment Any response to this notice must show clear, compelling, and convincing evidence that competition will be advantageous to the Government. The intent of this special notice is for informational purposes only. Information received will normally be considered solely for the purpose of determining whether to conduct competitive procurement. A decision by the Government not to compete this action based on this notice is solely within the discretion of the Government SAM REGISTRATION Respondents must be registered and active in SAM.gov. POSTING DURATION This notice will remain active for 60 calendar days. DISCLAIMER This notice does not obligate the Government to award a contract. No solicitation is available at this time. Responses will be used solely to determine whether additional sources exist that could fulfill the requirement.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Ronald T Heidemann
Contracting Officer

Documents

Files (1)

  • 36C25026Q0666.docx

    32 KBAdded in Special Notice version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Special NoticeArchived

    H946--Intent to sole source

    Notice 82b6d95728de4ffaa06007e2d4b440cd on SAM.gov

  2. 7
    Version 7Special NoticeArchivedCurrent

    H946--Intent to sole source

    Notice 235af171f5f14c0c8ea0ec5da3dbe948 on SAM.gov

  3. 5
    Version 5Justification

    Type changed from Special Notice to Justification

    H946--Service and Maintenance of Equipment Base + 4

    Notice e531922f9073416bb2fb953ac0931268 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This is a combined synopsis/solicitation for commercial services prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued. This solicitation is issued as a Request for Quotation (RFQ), solicitation number 36C25026Q0430. This solicitation incorporates provisions and clauses in effect through Federal Acquisition Circular (FAC) 2026-01 with an effective date of 03/17/2026. Contractor is responsible for submitting their package in accordance with the guidance in this solicitation. Failure to follow the document format or the solicitation guidelines will render the submission non-responsive and ineligible for consideration. This solicitation is set-aside for: 100% Service-Disabled Veteran Owned Business
-Combined Synopsis09/18/2026
Delivery Schedule: The coordinating service for this initiative is CVAMC Engineering CORS. All services will be approved, coordinated, and scheduled with the Engineering COR at contract award. All items will be delivered, and first maintenance scheduled within 30 days of contract award. Monthly service visits to be scheduled within the first week of each month. Quarterly PM service visits to be scheduled within the first week of each quarter. Service reports and water quality analysis reports should be delivered via email to the VAMC Engineering COR within five (5) business days of visit, or in the case of longer-duration tests, within three (3) days of receiving results from outside lab testing. All work must be performed during normal working shifts, 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays, however some tasks may need to be performed outside normal working shifts and days. The vendor will schedule & coordinate all work with Engineering COR and Chief SPS. The contractor personnel shall sign into (and out of) the facility and obtain a Vendor s ID Badge upon every visit at Engineering, Building 21. The contractor shall then check in and check out and report to the Engineering COR in Building 21 and return the Vendor s ID Badge to Engineering, Building 21. Period of Performance: Base Year + 4 Option Years. ========================================================================= Evaluation Factors - Chillicothe VAMC Sterile Processing Water Quality ===================================================================================== 1.Maintenance a. Experience and materials for service i. CPVC Piping and Fittings ii. Polypropylene Thermal Fusion Piping and Fittings iii. 5844C DI Tanks iv. Prefilter 5-micron melt blown cartridge - post DI 675100 v. Final 0.2-micron absolute polyester pleated cartridge 675145 vi. Carbon block 10-micron prefilter 2.5 x 20 cartridge 675113 vii .RO Membranes 4 x 26" XLE4021 viii. UV Lamp GL39PP (UV Lamp - 1 Year Life Change Sept) - UV module part number UVA-12C (Hydronix) b. Emergency Response Capability i. Declaration of response within 1 business day (as based on federal calendar) ii. Nearest Service Location 1.Locations within 100 miles will receive priority 2.Locations within 200 miles will receive preference 2.Water Quality Analysis a. Laboratory Qualifications i. ISO/IEC 17025 ii. Ohio Environmental Protection Agency (Not applicable to Endotoxins ANSI/AAMI ST72/USP 85) iii. Equivalent certification to be determined by facility review. b. Sampling Procedures i. Submit company policy/procedures. ii. Sampler Resume 1.Shall have a minimum of 5 years of experience. 2.Experience with biological sampling to include Heterotopic Plate Count and Endotoxin iii. Virtual interview with sampler will be requested c. Transportation and Storage Procedures i. Submit company policy/procedures ii. Maximum transit time not to exceed 8 hours to lab intake. d. Reporting i. Example Report Reviewed for contents and organization 1. Shall include: a. Biological analysis results b. Chemical analysis results c .AAMI ST108 Thresholds d. Identify Water* Quality Classification i. Utility Water ii. Critical Water iii. AER iv. Steam* - Steam Condensate e. Remediation recommendations 2. An actual report is permitted, however facility identifying information shall be redacted. 3. Report shall be watermarked or stamped on all pages with Example 3. Familiarity with AAMI ST108, Bacteriological Water Quality Management, and Water Treatment Technologies a. Specialist Resume(s) b. Virtual interview with specialist(s) will be requested. c. Specialist(s) may be an individual or multiple individuals. d. Bacteriological Water Quality Management i. Disinfection methods 1.Manual Administration a. Liquid disinfectants b. Dissolved oxidizing gas c. Concentration and Contact Time Requirements 2.Automated/Energized Systems a. Ultraviolet b. Metered liquid disinfection systems c. Dissolved oxidizing gas ii. Material/Chemical Compatibility iii. Safety Requirements iv. Costs 1. Initial 2. Operation/Maintenance e. Water Treatment Technology Familiarity i. Shall include: 1. Reverse Osmosis 2. Filtration Technologies a. To include Carbon Filtration 3. Ion Exchange Technologies 4. Water Softeners ii. Material/Chemical Compatibility iii. Sizing of Technology iv. Operations and Maintenance Requirements v. Safety Requirements vi. Costs 1.Initial 2.Operation/Maintenance
-Market Research09/03/2026
SBIR Phase I Proposal #B201B-0016. Ultrasonic PVDF Reduces Membrane Fouling for Efficient Water Reuse. Pure Blue Tech Inc.
-AwardedOpen
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of the sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses and Veteran Owned Small Businesses interested and capable of providing the services described below. Documentation on technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. The North American Classification System (NAICS) code for this acquisition is NAICS: 221310 Water Supply and Irrigation Systems. PSC: H246 Equipment and Materials Testing Water Purification and Sewage Treatment Equipment. Responses to this notice shall include the following: (a) Company name (b) Address (c) Point of contact (d) Phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned Small Business, Veteran owned small business (i) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. (j) Provide estimated pricing if you were to price today. The Veterans Health Administration (VHA) has a requirement at the Long Beach VA Medical Center, located at 5901 E 7th Street, Long Beach, CA 90822, for Reverse Osmosis, Deionization Equipment and PE Water Softeners Maintenance Service. STATEMENT OF WORK Project Title: Reverse Osmosis, Deionization Equipment and PE Water Softeners Maintenance Service Background: The Long Beach VA Healthcare System (LBVAHCS) requires full-service maintenance to ensure the SPS critical water system meets AAMI ST108 standards. This Reverse Osmosis (RO) water system is used for reprocessing reusable medical equipment (RME). Scope: Contractor shall, without exception, provide all hand tools, diagnostic test equipment, ladders, and anything else necessary to perform the work required to meet the scope. All services shall cover the following Government-owned equipment: 1 SCW Reverse Osmosis, Deionization Upright Skid 8000 gallon per day reverse osmosis 5.5 GPM 5, H5 4X40 thin Film Membranes staged 3-2 housed in Stainless housings 1, Fluid O Tech 4000 series Stainless Steel 10 GPM high pressure pump coupled to a 1.5 HP BALDOR motor 110/220-volt single phase TEFC Pretreatment: Soft Water feed Central Plant Softener supplied by others 1, Automatic Carbon 16X65 4 Cubic Foot 1.5 Clack control Valve 1, Cartridge Pre Filter, Big Grey 1 , 1-5 micron 20 X4.5 Big Grey Distribution Pumps: 2, GOULD s 15SV3FG4C60 5 HP 3Phase 304 SS Vertical pumps 60 GPM @ 70 PSI Storage Tank: 3,500 Gallon conical bottom 52 X81 DEN HARTOG Rotationally molded PE storage tank #CB0500-52, Metal Stand Post Treatment: 4, 1040 1.5 cubic foot Mixed Bed DI Running 2 online and 2 standby running in Series (Not part of sale exchange rental) Flow after RO to Storage Tank 7, 40 5-micron Filters, Housed in 1 SHELCO multi housing 304 Stainless steel 7FOS4 7, 40 Endotoxin Filters, housed in 1 SHELCO multi housing 304 stainless steel 7, FOS4 1, Ultraviolet Sterilizer s Atlantic Model S 5000Crated at 83 GPM running at 60 GPM, 2 NPT Instrumentation/Resistivity/Flow/PLC Mounted in Electrical panel Distribution Pumps : 1, METTLER M800 2 channel Monitor 0-18 MEG/OHM 2, Resistivity Sensor ISM 0-18 Meg 4-20 ma output 1, Horner HE-XW1E6 7 HMI / PLC with 4 AI, 4 Digital inputs and 1, 0-10 PSI 4-20 ma transducer Storage level 1, 0-150 PSI 4-20 ma transducer Loop pressure Inline Analyzers in Metal Cabinet 120/220-volt single Phase: 1, Endotoxin online ENODSAFE NEXGEN MCS and system software 1, TOC online analyzer METTLER 6000i 1, Microbial online analyzer METTLER Bio burden 7000RMS 1, Wall Mount Control Panel HMI/PLC Horner Standards to Adhere to: The Contractor shall adhere to AAMI ST 108 (https://blog.ansi.org/ansi/ansi-aami-st108-2023-water-quality-medical-devices/) Resistivity: 1,000,000 ohms/cm minimum Chlorides: < 10 G/L max Sodium: < 10 G/L max Silica: < 10 G/L max Bacteria: < 10 cfu/ml subset A Endotoxin: < 10 EU/ml Gallons per day: 8000 Distribution Loop Flow: 60 GPM @ 60 PSI Piping Material: SCH 80 PVC Interconnect piping, Stainless loop Ongoing Support Services: Monthly Reverse Osmosis (RO) Service to include: Read Monitor and Log equipment performance Reverse Osmosis and Distribution Replace pre Filter Big Grey 20 5 Micron Check Automatic Carbon Filter pressure and Chlorine removal Check City water TDS and Hardness Change out pre-DI 2-1040 Mixed beds 4- 1040 Mixed Bed DI Monthly Usage 4- 1040 Mixed Bed DI Exchange Log Distribution Pump pressure Log Post Filters Pressure Log Quality, RO/DI 3 Quarterly Sanitization services to include: No Post Filters No UV Lamp 2 Bacteria (Supply and Return) 2 Endotoxin (supply and Return) 2 Semi-Annual Loop Sanitization services to include: 2 Hours MINNCARE or EQUAL Solution Loop Run, 4 Hour total shut down Labs 2 Bacteria (Supply and Return) 2 Endotoxin (Supply and Return) Replace Pre Filters 7, 40 5 Micron Replace Post Filters 7, 40 .04 Endotoxin Replace UV Lamps (annually) Optional Monthly Labs: 2 Bacteria (Supply and Return) 2 Endotoxin (Supply and Return) Labor: The contractor will provide all labor associated with the repair of the equipment covered under the contract agreement. Inadequate or improper repairs performed by the contractor will be correctly repaired at a time convenient to the VA at no additional expense to the VA. There will be no limitation to the number of labor hours provided within the stipulated timeframes of contract coverage. Response Times: Contractor will acknowledge requests by telephone for service within 2 hours. The contractor must always contact the Biomedical Engineering at (tbd) before and after arrival at the site. Reporting Procedures: The Contractor must report to the Biomedical Engineering Department (Building 5, Room 138) to sign the visitor logbook. In addition to signing-in, the Contractor personnel shall wear their VA issued badge and identify him/herself to the Using Service before proceeding to the job site. For services to be performed outside normal working hours, the Contractor must obtain approval from the Biomedical Engineering Point of Contact prior to performing any afterhours work. If the afterhours request is approved, the Contractor must report to the Biomedical Engineering Department (Building 5, Room 138) to sign the visitor logbook and pick up a visitor badge. In addition to signing-in, the Contractor personnel shall identify him/herself to the Using Service before proceeding to the job site. Prior to leaving the facility, the Contractor shall communicate status of equipment to the Using Service and sign out of the logbook in the Biomedical Engineering Department. Note: To ensure proper equipment history documentation, the contractor will forward all preventive maintenance records within 5 working days of completion to Biomedical Engineering. Documentation: For Preventive Maintenance, Contractor will provide a PM checklist to VA Long Beach Biomedical Engineering, listing each action taken to complete the maintenance. Contractor will provide individual results which describe services performed (in sufficient detail to be acceptable to the field inspectors of The Joint Commission). The following information must be provided in each report: Date of service Summary of problem and action taken Parts replaced Labor hours Travel time Equipment serviced (description, Equipment ID #, serial number, etc.) Purchase order number Note: This report must be approved and signed by Biomedical Engineering personnel or their representative. The service report must be provided to Biomedical Engineering within 5 business days of service provided. A copy of each report will be left with Biomedical Engineering. In the event that Biomedical Engineering is not available to receive the service report (outside normal working hours), the service report will be left with the supervising official of the equipment that was serviced; the supervising official will forward the service report to Biomedical Engineering (138M) the next working day. Qualifications: Contractor must be engaged full-time in the service and support of the equipment listed in Section II. Contractor shall have access to complete service manuals Contractor shall have access to software diagnostic keys Contractor Badging: Compliance with Department of Veterans Affairs (VA) Handbook 0735 Homeland Security Presidential Directive 12 (HSPD-12) Program requirements, the Prime Contractor shall coordinate with the Program Office Point of Contact regarding all site visits to the VA Long Beach Healthcare System. Badges are mandatory for all contractors and subcontractors entering the facility. The Prime Contractor is responsible for ensuring that all required information and documentation are submitted to the Program Office Point of Contact with sufficient lead time to allow for proper processing of badge requests. No contractor or subcontractor may begin work onsite without an approved badge, except under emergency conditions as outlined below. Processing Time Badge issuance may take up to 30 calendar days due to required background checks. The Prime Contractor must begin coordination with the Program Office Point of Contact immediately upon contract award to avoid repair, service, or project delays. Onsite Visits for Badging Contractors should anticipate at least two separate onsite visits: One visit for fingerprinting. One visit to pick up the issued badge. Mandatory Training All contractors and subcontractors must complete mandatory training assigned through the VA s electronic Training Management System (TMS) before badges are issued. This training typically requires approximately two (2) hours to complete. Badge issuance and retention are contingent upon successful completion of this training. Emergency Repairs Exception In cases where an emergency repair or service is required and the contractor or subcontractor has not yet been issued a permanent VA badge, a temporary day badge may be issued by VA Police for that emergency only. The Prime Contractor must still ensure that permanent badging is pursued without delay following the emergency event. Period of Agreement: One-year period (12 months). Hours of Coverage: Normal hours of coverage will be Monday through Friday from 5am to 5pm PST. Service and/or repairs must be performed during stipulated hours of coverage unless requested or approved by Biomedical Engineering. Federal Holidays observed by the VA are: Date Holiday Monday, January 01 New Year s Day Monday, January 15 Birthday of Martin Luther King, Jr. Monday, February 19Â * Washington s Birthday Monday, May 27 Memorial Day Wednesday, June 19 Juneteenth National Independence Day Thursday, July 04 Independence Day Monday, September 02 Labor Day Monday, October 14 Columbus Day Monday, November 11 Veterans Day Thursday, November 28 Thanksgiving Day Wednesday, December 25 Christmas Day Important information: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this Sources Sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov and complete Online Representations and Certifications Application (ORCA). Additionally, all Service- Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be listed as verified on the Veteran Small Business Certification (VetCert) database at https://veterans.certify.sba.gov/. All interested Offerors that can meet the qualifications above should submit information by e-mail to naomi.meza@va.gov. All information submissions shall be received no later than 12:00 PM Mountain Standard Time on Friday, November 13, 2026.
-Market Research11/13/2026
-Market Research11/17/2026

Additional Details

Solicitation Number

36C25026Q0666

Archive Date

Oct 21, 2026

Office Address

DAYTON, OH, 45428