GovChime
Notice ID: 8e84a1ae0fda4879bc3f970869e99fffCombined Synopsis/Solicitation

Commercial Diesel Generator Set, 600kW Standby 60Hz

Responses closed . Full description on SAM.gov.

Overview

Response deadline
2:00 PM EDT
Posted
May 7, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
335312: Motor and Generator Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place of performance
4525 Camp Hale Rd Fort Drum, NY 13602, 13602
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S226U3180
Notice ID
8e84a1ae0fda4879bc3f970869e99fff

Description

Amended to include set aside code. Characteristics:600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing- UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts,105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet -Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up,Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary,8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Boxor Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker -1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Boxor Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50CAmbient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing -None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control:

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    Commercial Diesel Generator Set, 600kW Standby 60Hz

    Notice 10cf304348b04227922b6034a85d0d95 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationCurrent

    Commercial Diesel Generator Set, 600kW Standby 60Hz

    Notice 8e84a1ae0fda4879bc3f970869e99fff on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
150 kW Generator Dual FuelStandby Generator120/2083 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - Due date change. Amendment 0002 - EPA requirement correction.
100%
Combined Synopsis09/18/2026
350 kW Generator Dual Fuel Standby Generator 120/208 3 Phase. Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001- Due Date Modification. Amendment 0002- Corrected inaccurate EPA requirements.
100%
Combined Synopsis09/18/2026
150 kW Generator Dual Fuel Standby Generator120/2083 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - Correction to EPA requirements.
100%
Combined Synopsis09/18/2026
180 kW Generator Dual FuelStandby Generator120/2083 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - corrections to EPA requirements.
100%
Combined Synopsis09/18/2026
150 kW Generator Dual Fuel Standby Generator277/4803 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - Corrections to EPA requirements
100%
Combined Synopsis09/18/2026

Additional Details

Solicitation Number

W911S226U3180

Archive Date

May 7, 2027

Office Address

FORT DRUM, NY, 13602-5220