Repair Building 1064 - Kirtland Air Force Base, New Mexico
Archived on May 19, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM MDT
- Posted
- April 24, 2026
- Notice type
- Sources Sought
- NAICS
- 236220: Commercial and Institutional Building Construction
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- NATIONAL GUARD BUREAU.JFHQ USPFO NM.USPFO NM PROCUREMENT.W7NQ USPFO ACTIVITY NMANG 150
- Place of performance
- ROAD FORKS, New Mexico, 87117
- PSC
- Y1AZ: CONSTRUCTION OF OTHER ADMINISTRATIVE FACILITIES AND SERVICE BUILDINGS
- Last updated
- Nov 1, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W50S8G26B0001
- Notice ID
- daa5daeef21f47e08278a966d71a2fd5
Description
Amendment II – Corrected Title of Sources Sought from Building 1664 to 1064.
--------------------------------------------------------------------------------------------------------------------------
Amendment I – Response date has been changed from May 1, 2026, to May 4, 2026.
--------------------------------------------------------------------------------------------------------------------------
The purpose of this synopsis is to gain knowledge of potential sources for this project including interested Small Business sources. This notice is for planning purposes only. All interested parties should respond. The New Air Mexico National Guard, Kirtland Air Force Base, New Mexico intends to issue a solicitation, an Invitation for Bid (IFB), and award of a contract to Upgrade Building 1064. The work for this requirement to include but not limited to:
Repair of administration and shop area finishes through patching and painting surfaces, replacing ceiling tiles, replacing floor finishes, and altering selective areas to improve operations. Replace roofing system with 30-year PVC roof. Repair HVAC system to meet the new functions. Repair interior and exterior electrical systems to current safety requirements, replace existing lighting with energy efficient lighting and controls. Repair restrooms to include surfaces and fixtures with water efficient systems. Repair doors and door seals. Replace overhead doors with insulated sectional and roll up doors. Repair the fire suppression system. Full depth reconstruction of parking lot and driveway. Reconstruct drainage drop inlets and water pathways to improve drainage. Remove irrigation and grass areas, install xeriscape to all areas. The size of the building is 10,265 square feet.
The Revolutionary Federal Acquisition Regulation Overhaul Part 36 no longer authorizes the disclosure of magnitude of construction projects as of 1 February 2026. All interested concerns will provide this office, in writing via email, a notice stating their positive intent to participate in the IFB as a prime contractor no later than the date of this announcement.
This notification shall not exceed five typewritten pages and must include:
(1) positive statement of intent to bid as a prime contractor,
(2) a completed and signed Source Sought Information Request Form, attached to this announcement, and
(3) A listing of projects completed during the past five years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor.
(4) A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract.
In the event adequate Small Business firms are not available for adequate competition for this project, it may be advertised as unrestricted. Information shall be provided via email to: David Best at david.m.best.civ@army.mil, Michael Dixon at michael.d.dixon82.civ@army.mil, and SMSgt Edwin Widgeon at edwin.widgeon@us.af.mil.
Include the following in the subject line of email, Sources Sought W50S8G26B0001. No facsimile responses will be honored.
Award Overview
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (1)
- Download
Sources Sought Response Form - W50S8G206B0001.pdf
3.7 MBAdded in Sources Sought version 1Posted
Lifecycle
- 1Version 1Sources SoughtArchived
Repair Building 1664 - Kirtland Air Force Base, New Mexico
- 2Version 2Sources SoughtArchived
Repair Building 1664 - Kirtland Air Force Base, New Mexico
- 4Version 4Sources SoughtArchivedCurrent
Repair Building 1064 - Kirtland Air Force Base, New Mexico
- 7Version 7PresolicitationArchived
Type changed from Sources Sought to Presolicitation
Repair Building 1064 - Kirtland Air Force Base, New Mexico
Similar Opportunities
Additional Details
Solicitation Number
W50S8G26B0001
Archive Date
May 19, 2026
Office Address
KIRTLAND AFB, NM, 87117-5875