GovChime
Notice ID: 2439e8363f724dfa97668045fc1de673Award NoticeAwardedArchived

F101--Environmental Compliance Support Services for the Greater Los Angeles VA Healthcare System

Awarded on July 16, 2026. Full description on SAM.gov.

Awarded tounder 36C26226P1289 (source: SAM.gov award notice)• $99.9K

Overview

Posted
July 20, 2026
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
541620: Environmental Consulting Services
Agency
Department of Veterans Affairs

Notice details

Office
262-NETWORK CONTRACT OFFICE 22 (36C262)
Place of performance
Department of Veterans Affairs, Tucson, AZ, 85723
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov
Award date
Jul 16, 2026
Award amount (SAM.gov award notice)
$99.9K

Identifiers

Solicitation number
36C26226Q0985
Notice ID
2439e8363f724dfa97668045fc1de673
Award number (PIID)
36C26226P1289

Description

The purpose of this amendment is the following: To respond to inquiries from vendors seeking information and clarification for RFQ 36C26226Q0985 (See answers to inquiries below in this amendment). To extend the offer due date/time to No Later Than July 06, 2026, at 02:00 PM Pacific Standard Time (PST). Contractor Inquiries- Environmental Compliance Support Services for GLA Is Biennial Hazardous Waste Reporting required for the odd reporting year, 2027? Can you please clarify the requirement for the Biennial Hazardous Waste Reporting during this period of performance? The Scope of Work states to complete the Biennial Hazardous Waste Reporting for multiple locations. Biennial hazardous waste reporting is required on even reporting years, which means the reporting is next due in 2028. The period of performance end date is 04/19/2027. The Biennial Hazardous Waste 2025 report is overdue. Reporting will need to be completed during the period of this contract.

Full description on SAM.gov

Award Overview

Award Number

36C26226P1289

Award Amount (SAM.gov award notice)

$99.9K

Award Date

Jul 16, 2026

Awardee

Awardee UEI

EG15L8DBNR78

Awardee CAGE Code

88Q83

Awardee Address

SACRAMENTO, CA 95834, CA

Original Solicitation

Notice ID: 2439e8363f724dfa97668045fc1de673

Posted Date: Jul 20, 2026

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C26226P1746
    PACIFIC COAST CONTRACTING GROUP
    Department of Veterans AffairsNAICS 541620
    $98.1KSigned Sep 18, 2026
  • 36C26226P0675
    PACIFIC COAST CONTRACTING GROUP
    Department of Veterans AffairsNAICS 541620
    $35.0KSigned Jul 29, 2026
  • 36C26226P0675
    PACIFIC COAST CONTRACTING GROUP
    Department of Veterans AffairsNAICS 541620
    $35.0KSigned May 22, 2026
  • 36C26226P0675
    PACIFIC COAST CONTRACTING GROUP
    Department of Veterans AffairsNAICS 541620
    $35.0KSigned Apr 14, 2026
  • 36C26225P1391
    PACIFIC COAST CONTRACTING GROUP
    Department of Veterans AffairsNAICS 541620
    $34.5KSigned Jun 6, 2025

Contacts

Contracting Officer

Primary Contact

Jennell Christofaro
Contracting Specialist

Documents

Files (5)

  • 36C26226Q0985 0001.docx

    26 KBAdded in Combined Synopsis/Solicitation version 10Posted
    Download
  • VAAR 852.219-75VA Notice of Limitations on Subcontracting Certificate of Compliance for Services.docx

    18 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • VAAR 852.219-73+Notice+of+Total+Set-Aside+for+Certified+SDVOSB.pdf

    124 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • 36C26226P1289_1.docx

    22 KBAdded in Award Notice version 4Posted
    Download
  • 36C26226Q0985.docx

    53 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 5
    Version 5Combined Synopsis/SolicitationArchived

    F101--Environmental Compliance Support Services for the Greater Los Angeles VA Healthcare System

    Notice 91e49701f8f24f999972e62d0bde0577 on SAM.gov

  2. 4
    Version 4Award NoticeArchivedCurrent

    Type changed from Combined Synopsis/Solicitation to Award Notice

    F101--Environmental Compliance Support Services for the Greater Los Angeles VA Healthcare System

    Notice 2439e8363f724dfa97668045fc1de673 on SAM.gov

Other notices for this solicitation

  1. Combined SynopsisRelated noticeJun 22, 2026

    F101--Environmental Compliance Support Services for the Greater Los Angeles VA Healthcare System

    Notice b8a376b0cdfd4aeaa7e6ccb6be222b29 on SAM.gov

  2. Combined SynopsisRelated noticeJun 22, 2026

    F101--Environmental Compliance Support Services for the Greater Los Angeles VA Healthcare System

    Notice c51f743768b74c25bfa1b3dec6c21d5f on SAM.gov

  3. AwardedRelated noticeJul 20, 2026

    F101--Environmental Compliance Support Services for the Greater Los Angeles VA Healthcare System

    Notice ba6928a85d2b4340b91f5ef5e121d19c on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
The answers to all questions will be posted on 12/15/2026. No new questions will be accepted. Bid due date has been extended to 12/22/2026 at 10:00AM Pacific time zone.
-Combined Synopsis12/22/2026
-Combined Synopsis11/12/2026
The purpose of this modification (#1) is to answer questions: Question 1: Typically, VPIH means Veterans Professional Industrial Hygienist which generally falls under NAICS code 541620 (Environmental Consulting). Could you please clarify what your definition of VPIH is and why you chose 562910 (Remediation Services). Answer: The NAICS code is changed to 541620 (Environmental Consulting). Question 2: The Scope of Work appeared rather vague in what the duties of the VPIH would be "VPIH firm to provide VPIH Services for construction project 657A4-21-800" Based on my experience as VPIH, that means overseeing asbestos abatement activities, visual inspections, air clearance sampling, etc. Could you please provide more details on what you envision the VPIH duties entailing. Answer: Here are more details about the project. Full details will be provided in the request for proposal to the top firm. - The VA Professional Industrial Hygienist (VPIH) shall provide all labor, materials, equipment and supervision necessary to review abatement personnel s documentation compliance monitoring, Phase Contrast Microscopy (PCM) air monitoring & analysis, inspections, clearance testing, and removal activities for the duration of the abatement as required by the project plans and specifications. - Asbestos/Lead abatement project oversight work will be performed in separate locations in Building 1 based on design documents. - The VPIH shall provide a final report for each location, at the end of the Asbestos Containment Material (ACM) abatement, which includes a summary of pre-abatement and post-abatement activities. - All routine air sample results shall be delivered to the Contracting Officer s Representative (COR) within 24 hours of collection. All clearance samples shall be delivered to the COR within 24 hours from the collection. Question 3: Generally Consulting services, if this is for a VPIH, do not require an SF 330 submittal. Could you please explain why this is apparently requiring an SF 330 submittal directed at A/E firms. Answer: This project is being solicited as an A/E project. Therefore, SF 330s are required. -----------------------END------------------------
-Pre-Solicitation11/02/2026
Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS
-Combined Synopsis11/12/2026
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.
-Combined Synopsis11/12/2026

Additional Details

Solicitation Number

36C26226Q0985

Archive Date

Aug 4, 2026

Office Address

Gilbert, AZ, 85297