GovChime
Notice ID: 098ad8ecd3e148fba56d1031d023ffe3Combined Synopsis/Solicitation

Endoscopy Systems

Archived on October 1, 2026. Original response deadline: . Full description on SAM.gov.

Description

Under FDA guidance, this OSEL-DIDSR collaboration requires an endoscope to maximize scientific research capacity throughout the center and agency. An endoscope allows OSEL researchers to develop bench testing methods for evaluating the safety and effectiveness of endoscopy devices.

The Government requires an endoscope system (Endoscope) with the following minimum requirements:

  • The Endoscope shall be shipped to the following address:

Attention to: TBD

10903 New Hampshire Ave WO62-3133, US FDA

Silver Spring, MD 20993-

  • Shipping cost is included in the total purchase price.
  • The Endoscope shall include the video processor, colonoscope, medical display, and cart that are interoperable with each other. Once assembled, these components shall operate as a fully functional endoscopy system that can acquire and display live image.
  • The video processor shall satisfy the following requirements:
    • The video processor shall be an FDA-cleared 510(k) medical device. The database is publicly available at 510(k) Premarket Notification.
    • The light source shall be integrated within the video processor.
    • The light source shall use three (3) or more LEDs to synthesize different spectra.
    • The video processor shall have the white light mode.
    • The video processor shall have two (2) or more narrow-band imaging (NBI) modes that utilize different optical spectra generated by the LED-based light source. The NBI modes shall be FDA-cleared for visualizing biological features such as blood vessels or mucosal surfaces.
    • The video processor shall have two (2) or more digital color enhancement modes that utilize different digital image processing techniques. These color enhancement modes shall be FDA-cleared under the FDA product code “PEA”.
    • The video processor shall have the following video output ports and video formats:
      • 12G-SDI (3840x2160x60p)
      • 3G-SDI (1920x1080x60p)
      • HD-SDI (1900x1080x60i)
    • The video processor shall have the capability of saving still images in a standard image file format such as TIFF or JPEG.
    • The video processor shall have the capability of saving video clips in a standard video file format.
  • The colonoscope shall satisfy the following requirements:
    • The colonoscope shall be an FDA-cleared 510(k) colonoscope device.
    • The direction of view shall be forward viewing.
    • The field of view shall be 170 ° or wider.
    • The depth of field shall cover the range of 5-100 mm or wider.
    • The angulation (up/down/right/left) shall be 180°/180°/160°/160° or larger.
    • The colonoscope shall have a water nozzle.
    • The insertion tube diameter shall be 12.8 mm or smaller.
    • The colonoscope shall have an instrument channel with diameter of 3.7 mm or larger.
  • The medical display shall satisfy the following requirements:
    • The signal input ports shall include:
      • 12G-SDI
      • 3G-SDI
      • Display Port
      • HDMI
      • DVI
    • The pixel count shall be equal to or greater than 3840x2160 pixels (4K).
    • The display size (diagonal) shall be equal to or greater than 32 inches.
  • All components in the system shall be powered by the standard 120 volts, 60 Hertz alternating current power in the U.S.

The Endoscope shall include a total system warranty for at least one (1) year, inclusive of any parts, labor, travel, and shipping cost to return the system to the original equipment manufacturer (OEM) standards.The Contractor shall deliver the endoscope within six (6) weeks of contract award. The Contractor shall provide a one (1)-year warranty period following system acceptance.

Full description on SAM.gov

Overview

Agency:
Department of Health and Human ServicesFOOD AND DRUG ADMINISTRATION
Office:FDA OFFICE OF ACQ GRANT SVCS
Posted:September 14, 2026
NAICS:423490: Other Professional Equipment and Supplies Merchant Wholesalers
Last Updated:Oct 23, 2026
First published:
Last updated on SAM.gov:
PSC:6640: LABORATORY EQUIPMENT AND SUPPLIES
Set-Aside:No Set aside used
Type:Combined Synopsis/Solicitation
Place of Performance:Silver Spring, Maryland, 20993

Award Overview

Possible prior contracts

Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (2)

  • SF30_75F40126Q00381_Amend0001.pdf

    106 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • 75F40126Q00381_amend0001.docx

    81 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    Endoscopy Systems

    Notice 9264f364fda749eca57c384f64b58f2e on SAM.gov

  2. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Endoscopy Systems

    Notice 098ad8ecd3e148fba56d1031d023ffe3 on SAM.gov

Similar Opportunities

Title
Phase
Agency
NAICS
Set Aside
Posted
Deadline
Location

Additional Details

Solicitation Number

75F40126Q00381

Archive Date

Oct 1, 2026

Office Address

Rockville, MD, 20852