Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

Awarded on September 2, 2025. Full description on SAM.gov.

Awarded tounder 36C25525C0061 (source: SAM.gov award notice)• $3.3M

Overview

Posted
September 2, 2025
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of Veterans Affairs

Notice details

Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Place of performance
St. Louis VAMC Jefferson Barracks 1 Jefferson Barracks Drive, St. Louis, 63125-4199
Last updated
Nov 8, 2026
First published
Last updated on SAM.gov
Award date
Sep 2, 2025
Award amount (SAM.gov award notice)
$3.3M

Identifiers

Solicitation number
36C25525R0097
Notice ID
22f56b762b714f2dba97cd30584dda1f
Award number (PIID)
36C25525C0061

Description

RFI #65. Can the morgue be shut down during construction? Providing temp cooling for that area to the degree required will be between difficult and impossible. If the shutdown is not possible, can you please provide clarification on how temp cooling for that area is to be accomplished so we can properly price this scope? Including the size and placement of temp unit/units that will achieve the appropriate temperatures? We don't use the JB morgue too often. Most patients that pass at JB go directly to the funeral home. The morgue is only used with the veteran does not have funeral home plans in place. The backup plan is the patient will be transported to JC morgue until funeral home arrangements are made. RFI #70. Sizing the temp units based on a preconstruction TAB report will not enable us to provide the proper pricing for our scope of work. This information needs to be available for us to include the correct pricing at the time of our bid not after we are awarded the project. Otherwise, it becomes and guess which usually drives the price up. AHU-01-1 Trane CSHX0035F3 (OR EQUIVALENT) (with electric heat), 7000 CFM Nominal, 5in Max ESP, 460V 3 Phase, MCA 179.8A, MOP 200A. Note: The contractor shall coordinate required electrical connection with the VA. AHU-01-2 Trane CSHX0035F3 (OR EQUIVALENT) (with electric heat), 7000 CFM Nominal, 5in Max ESP, 460V 3 Phase, MCA 179.8A, MOP 200A. Note: The contractor shall coordinate required electrical connection with the VA. AHU-24-1 Trane CSH0050F4 (OR EQUIVALENT) (with electric heat), 10000 CFM nominal, 5in Max ESP, 460V 3 Phase, MCA 232.2A, MOP 250A. Note: 460V unavailable at building 24. The contractor shall coordinate required electrical connection with the VA.. AHU-51-1 Trane RSHX0080 (OR EQUIVALENT) (with electric heat), 12,800 CFM nominal, 4.8in Max ESP, 460V 3 Phase, MCA 329A, MOP 400A Note: 460V unavailable at building 24. The contractor shall coordinate required electrical connection with the VA. If alternate is used, unit must have adequate capacity for DOAS application. The needs of the station and the temporary units are based on availability. The information provided is to ensure the contractor understands the situation and the need to ensure a maintenance team/ plan is made available by the subcontractor to avoid any issues with the temporary cooling during construction. Power can be provided to the temporary units as follows: Building 1: Feed the temporary AHU from 208V panel EMDP . Provide temporary transformer and connections as necessary. Building 24: Feed the temporary AHU from 208V External Wireway . Provide temporary transformer and connections as necessary. Building 51: Feed the temporary AHU from 208V switchboard MSB-51A . Provide temporary transformer and connections as necessary. RFI #72, 73 & 108. We need the design team to provide the proper information on the steam trap sizing and placement. Including the traps at the units and any drip traps that might be required. This is a complicated issue that would need to be designed .by the design team .not the installing contractor. Drip traps are generally based on the pounds per hour capacity of the main. This information is not available to us. Steam trap to be placed at the unit steam coil / humidifier. Anticipated piping lengths do not require steam drip traps. Contractor to verify and report the piping lengths from steam mains. STEAM TRAP SCHEDULE BASIS OF DESIGN MANUFACTURER TRAP NO. TRAP SIZE MAX PRESSURE (PSI) STEAM CONDENSATE LOAD CONSTRUCTION AHU-1-01 HEATING COIL SPIRAX SARCO FT450-4.5 1" 15 217 STAINLESS STEEL AHU-1-02 HEATING COIL SPIRAX SARCO FT450-4.5 1" 15 276 STAINLESS STEEL AHU-24-01 HEATING COIL SPIRAX SARCO FT450-4.5 1-1/2" 15 466 STAINLESS STEEL AHU-51-01 HUMIDIFER SPIRAX SARCO FT450-4.5 3/4" 15 23 STAINLESS STEEL NOTE: STEAM TRAP CONNECTION SHALL BE RAISED FACE FLANGE. Additional Information regarding RFIs 97 and 100: 3C06 As builts and site photos: Condensate pumps in basement mechanical room GC18: Location of the Steam supply and condensate return riser main connection to horizontal main. No as-built of the steam condensate pump is available in Building 1, Room GC18. The steam riser main is 2-1/2 and the condensate return riser main is 2 based on as-built drawings available as noted above.

Full description on SAM.gov

Award Overview

Award Number

36C25525C0061

Award Amount (SAM.gov award notice)

$3.3M

Award Date

Sep 2, 2025

Awardee

Awardee UEI

MWZUVWXJ6EE5

Original Solicitation

Notice ID: 22f56b762b714f2dba97cd30584dda1f

Posted Date: Sep 2, 2025

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C25526C0062
    RECON CONSTRUCTION SPECIALTIES LLC
    Department of Veterans AffairsNAICS 238220
    $3.1MSigned Aug 20, 2026
  • 36C25526C0009
    RECON CONSTRUCTION SPECIALTIES LLC
    Department of Veterans AffairsNAICS 238220
    $912.8KSigned Jul 8, 2026
  • 36C25526C0034
    RECON CONSTRUCTION SPECIALTIES LLC
    Department of Veterans AffairsNAICS 238220
    $9.0MSigned Jul 8, 2026
  • 36C25525C0043
    RECON CONSTRUCTION SPECIALTIES LLC
    Department of Veterans AffairsNAICS 238220
    $2.5MSigned Jul 1, 2026
  • 36C25526C0028
    RECON CONSTRUCTION SPECIALTIES LLC
    Department of Veterans AffairsNAICS 238220
    $294.8KSigned Apr 7, 2026

Contacts

Contracting Officer

Primary Contact

Jennifer Hill
Contract Specialist

Documents

Files (23)

  • 36C25525R0097 0005.docx

    2.9 MBAdded in Solicitation version 8Posted
    Download
  • 36C25525R0097 0004.docx

    16 KBAdded in Solicitation version 5Posted
    Download
  • 36C25525R0097 0003.docx

    16 KBAdded in Solicitation version 4Posted
    Download
  • 230711 - HVAC AND BOILER PLANT INSULATION.pdf

    166 KBAdded in Solicitation version 3Posted
    Download
  • TEMP-PRC001A-EN_06162024.pdf

    6.1 MBAdded in Solicitation version 3Posted
    Download
  • ssc-cat_spirax-sarco-ft-traps.pdf

    2.0 MBAdded in Solicitation version 3Posted
    Download
  • 36C25525R0097 0002.docx

    21 KBAdded in Solicitation version 3Posted
    Download
  • PreProposal Conference Site Visit Agenda 657-23-101JB.pdf

    159 KBAdded in Solicitation version 2Posted
    Download
  • MO20250089 06-13-2025.pdf

    109 KBAdded in Solicitation version 2Posted
    Download
  • VA_St_Louis_MO_AHU_Updated_Selections.pdf

    3.7 MBAdded in Solicitation version 2Posted
    Download
  • PPQ- 657-23-101JB.docx

    35 KBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB Pre-proposal sign-in.jpg

    4.3 MBAdded in Solicitation version 2Posted
    Download
  • 36C25525R0097 0001.docx

    6.0 MBAdded in Solicitation version 2Posted
    Download
  • 852.219-75 VA Notice of Limitations on Subcontracting - Certificate of Compliance for Services and Construction.docx

    11 KBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_-Final Drawings Part-6.pdf

    2.6 MBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_-Final Drawings Part-5.pdf

    9.1 MBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_-Final Drawings Part-4.pdf

    8.9 MBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_-Final Drawings Part-3.pdf

    9.5 MBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_-Final Drawings Part-2.pdf

    9.6 MBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_-Final Drawings Part-1.pdf

    9.9 MBAdded in Solicitation version 2Posted
    Download
  • 657-23-101JB_Final Specifications.pdf

    8.2 MBAdded in Solicitation version 2Posted
    Download
  • 36C25525C0061_1.docx

    13 KBAdded in Award Notice version 5Posted
    Download
  • 36C25525R0097_1.docx

    135 KBAdded in Solicitation version 2Posted
    Download

Lifecycle

  1. 3
    Version 3SolicitationArchived

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 97f5b269a23c4ee08e4a2fbd4f6ef9b8 on SAM.gov

  2. 5
    Version 5Award NoticeArchivedCurrent

    Type changed from Solicitation to Award Notice

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 22f56b762b714f2dba97cd30584dda1f on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationRelated noticeMay 20, 2025

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 0b07b3b41eae4c4aa50acf04b98c5dcd on SAM.gov

  2. SolicitationRelated noticeMay 29, 2025

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 1945676ff032487f92cbba6088e7d1f1 on SAM.gov

  3. SolicitationRelated noticeJul 10, 2025

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 8022eb4834da4cdf8e073c19cb70b850 on SAM.gov

  4. SolicitationRelated noticeJul 17, 2025

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 2db77821760f41dc8447721a1355f973 on SAM.gov

  5. SolicitationRelated noticeJul 24, 2025

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 97953b2c371d4b149b50bf2f26c4bf55 on SAM.gov

  6. SolicitationRelated noticeAug 4, 2025

    Z1DA--657-23-101JB FCA Replace Various Air Handling Units/Chillers Buildings 1, 24 and 51

    Notice 53b42e9bdd50400fa2776066ef90e1f5 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C25525R0097

Archive Date

Oct 2, 2025