GovChime
Notice ID: 66647c860d4249cfa353eff8c20c5e98Combined Synopsis/SolicitationArchived

Giant Voice System Maintenance

Archived on June 10, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
May 20, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
811210: Electronic and Precision Equipment Repair and Maintenance
Agency
Department of WarDepartment of the Air Force

Notice details

Office
AIR COMBAT COMMAND.FA4830 23 CONS CC
Place of performance
Fort Moore, Georgia, 31699
PSC
J063: MAINT/REPAIR/REBUILD OF EQUIPMENT- ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
Last updated
Oct 29, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
FA483026Q0027
Notice ID
66647c860d4249cfa353eff8c20c5e98

Description

Amendment 0001- 

The purposes of Amendment 0001 is to:

1. Amended Attachment 2. Price Schedule.

2. Revised Statement of Work- 19 May 2026

2. Struckthrough inaccurate information listed in the Combo

3. Incorporate Wage Determination 2015-4493 Rev. 31, 13 May 2026

4. Amended SF 1449

4. Exend the response deadline to: 1200 PM EST on 26 May 2026

This is a combined synopsis and solicitation for commercial service prepared in accordance with (IAW) format in Federal Acquisition Regulation (RFO) part 12, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation will not be issued

Requirement Title: Giant Voice System Maintenance

Solicitation Number: FA483026Q0027

Solicitation Issue Date: 8 May 2026

Solicitation Updated: 13 May 2026 (only POC's and CO listed have been updated on solicitation)

Response Deadline: 2:00PM EST on 18 May 2026

Point(s) of Contact: SSgt Samantha Elia, Mrs. Amanda Richardson

Contracting Officer: Mrs. Amanda Richardson

Interested vendors are advised to review the attached Combined Synopsis/Solicitation, SF1449, and Statement of Work (SOW) for complete requirement details, submission instructions, and applicable terms and conditions

SCOPE

Moody AFB is seeking sources capable of providing the maintenance and sustainment of Emergency Mass Notification System (EMNS) Giant Voice (GV). The work entailed will provide for properly provisioning a preventive maintenance schedule and actions to ensure the serviceability of the system.

OBJECTIVES

Conduct one annual Preventive Maintenance Inspections and system upgrades at Moody AFB. All visits shall be accomplished by technicians proficient in the type of work for inspecting and testing the entire EMNS system consisting of the following:

  • 3 base station locations and equipment:
    • Command Post
    • Alternate Command Post
    • 23 CS/SCOTR Shop
  • EMNS power supplies at each location.
  • Perform diagnostic testing at each siren location, which includes performing a quiet test and inspecting the condition of each siren pole and antenna.
  • Perform functional testing – Note: Sounding of the warning sirens is a necessary part of inspection procedures, to include public address and ATHOC. Note: Moody Command Post must have previously obtained approval to sound the sirens in advance of technicians arriving on base.
  • Perform diagnostic tests REACT 5000 and associated computers.
  • Ensure latest software upgrades are included and installed on each computer throughout the year.
  • All EMNS poles and Sirens (Quantity 11)
    • Verify proper grounding at all siren sites.
    • Inspect interior and exterior of cabinet for corrosion.
    • Ensure inside of cabinet is clean and dry.
    • Load-test all batteries installed in siren battery cabinets to ensure they measure at least 25 volts DC at the RTU’s main circuit board.
    • Check charger’s DC voltage located on main circuit board voltage should measure approximately 30 volts DC.
    • Ensure all wires and circuit connections are secure and seated firmly.
    • Ensure speakers are free of animals and nesting materials.
    • Inspection of all radios installed within each siren control cabinet, its antenna and associated antenna cable, and all base station equipment.
    • Verify proper grounding at all sites.
    • Inspection of all radios installed within each siren control cabinet, its antenna and associated antenna cable, and all base station equipment.
  • Provide an emergency call-out within 24 hours and all non-emergency calls within 5 duty days. Routine issues are deemed less urgent, and a response within five duty days is acceptable for these cases. The vendor is expected to respond promptly to emergency requests, particularly during extreme weather conditions. For emergency issues that cannot be resolved over the phone and when the local technician is unavailable, the response time may be extended to 48-72 hours. In such cases, the Contractor shall dispatch a field service representative.

DELIVERABLES

Provide test and measurement data for all work accomplished during each inspection visit. Contractor shall submit reports electronically to the 23 CS within five (5) calendar days of work completion. Reports shall be available in electronic format that is Microsoft Word, Microsoft Excel or Adobe PDF compatible.

ANNUAL INSPECTION AND ROUTINE CARE

Contractor shall begin the annual inspection with a customer meeting to review the siren system service log and overall performance of the system over the past year. After completion of the preventative maintenance inspection (PMI), the contractor shall produce the results of the PMI report on the condition of all inspected areas.

PERSONNEL QUALIFICATIONS

Site POC, and respective alternate(s) shall be able to read, write, speak, and understand English. Site POC or respective alternate(s) are required to be a qualified trained technician with experience working with ATI Giant Voice (GV) equipment and systems.

SAFETY

The Contractor shall observe all Safety, Security, Traffic and Fire regulations presently enforced at Moody Air Force Base. Contractors shall comply with the OSHA (OSHA, Public Law 91-596) and the resulting standards, OSHA Standards 29 CFR 1910 and 1926. The detailed provisions of the act for accident prevention are directly applicable to all Contractor operations. Prime Contractors are also responsible for ensuring any sub-contractors also adhere to OSHA Guidance. OSHA compliance officers can visit Contractor worksites on the installation.

Responses to this Solicitation request should reference "Giant Voice System Maintenance - Moody AFB"

Responses must be submitted electronically to the following e-mail addresses: samantha.elia@us.af.mil and amanda.richardson.13@us.af.mil. All correspondence sent via email should contain a subject line that reads “Response to Moody AFB Giant Voice System Solicitation.” If this subject line is not included, the e-mail may not get through e-mail filters at Moody AFB. Filters are designed to delete emails without a subject or with a suspicious subject or attachment. Attachments with files ending in .zip or .exe are not allowable and may be deleted. Ensure only .pdf, .doc, .docx, .xsls, or .xls documents are attached to your email. All other attachment types may be deleted.

Direct all questions concerning this Solicitation to samantha.elia@us.af.mil and amanda.richardson.13@us.af.mil no later than Thursday, 14 May 2026 at 3:00 PM EST

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (11)

  • Amendment 0001 SF1449- FA483026Q0027.pdf

    768 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Attachment 2 - Price Schedule.xlsx

    24 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Attachment 1 Statment of Work Giant Voice System MAFB 19 MAY.pdf

    199 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Attachment 5 Wage Determination 2015-4493 Rev. 31 13 May 2026.pdf

    4.1 MBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Amended Combined Synopsis Service_Giant Voice.pdf

    349 KBAdded in Combined Synopsis/Solicitation version 4Posted
    Download
  • Attachment 3 Contract Insurance Compliance.pdf

    1.5 MBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Attachment 4 Mission Essential Contractor Services Plan.docx

    24 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Attachment 5 Wage Determination 2015-4493 Rev. 31 30 March 2026.pdf

    47 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Attachment 6 Base Access Request.docx

    202 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Attachment 7 Base Map.pdf

    1.4 MBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Attachment 8 Questions and Answers.docx

    24 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    Giant Voice System Maintenance

    Notice a6b91a29602a498086f236c1064527f0 on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationArchived

    Giant Voice System Maintenance

    Notice d4fbd10e8818403c8450ede0b10857a9 on SAM.gov

  3. 3
    Version 3Combined Synopsis/SolicitationArchived

    Giant Voice System Maintenance

    Notice 182ba03a5b3e438bb9db29c71beb4f37 on SAM.gov

  4. 4
    Version 4Combined Synopsis/SolicitationArchived

    Giant Voice System Maintenance

    Notice 010158d5e28340eb8fbf2a578f9680eb on SAM.gov

  5. 6
    Version 6Combined Synopsis/SolicitationArchivedCurrent

    Giant Voice System Maintenance

    Notice 66647c860d4249cfa353eff8c20c5e98 on SAM.gov

  6. 9
    Version 9Award NoticeArchived

    Type changed from Combined Synopsis/Solicitation to Award Notice

    Giant Voice System Maintenance

    Notice 3dba6d91eadc4678839176ee0069584f on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

FA483026Q0027

Archive Date

Jun 10, 2026

Office Address

MOODY AFB, GA, 31699-1700