Boiler Inspection and Repairs
Archived on September 26, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM EDT
- Posted
- September 9, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of Homeland SecurityFEDERAL LAW ENFORCEMENT TRAINING CENTER
Notice details
- Office
- FLETC PROCUREMENT CHELTENHAM OFFICE
- Place of performance
- Cheltenham, Maryland, 20623
- PSC
- J042: MAINT/REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 70LCHE26QPFB00004
- Notice ID
- f687e995b409431e88e640f26c1f9635
Description
The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors.
The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers.
Bidders are responsible for verifying all site conditions and quantities prior to bid submission.
The Contractor shall provide a complete inspection and troubleshooting service, which includes:
- Submitting a detailed assessment checklist noting all deficiencies.
- Providing a line-item cost estimate to correct any identified deficiencies.
- Ensuring the inspection covers, at a minimum:
- Mounting, Isolators, and Filter Components
- Burner and Gas Train
- Breeching and Combustion Air
- Boiler Inspection and Chemical Treatment
- Fan functionality
- Sight Glass, Water Piping, Gas Piping, and associated valves
- Electrical connections, including disconnect switch and safety circuits
- Control systems, firing sequences, and interlocks
- Safety controls, flame safeguards, and low water cutout
- Pressure and temperature gauges
- Testing of the safety relief valve
- Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).
Award Overview
No prior contract identified
No matching prior contract was found within an 18-month window using the same agency, NAICS, place-of-performance state, and PSC. This may be a new requirement, or the prior award uses a different classification.
Contacts
Contracting Officer
Primary Contact
Documents
Files (7)
- Download
Site Visit Sign in sheet.pdf
445 KBAdded in Combined Synopsis/Solicitation version 6Posted - Download
Amendment 04 Site Visit Questions.pdf
54 KBAdded in Combined Synopsis/Solicitation version 6Posted - Download
Amendment 03 Questions.pdf
114 KBAdded in Combined Synopsis/Solicitation version 4Posted - Download
Boiler Inventory 9-2-2026.pdf
62 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
26OCH9006-1 SOW Boilers Revised.pdf
199 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
Boiler RFQ.pdf
124 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
Wage Determination 15-4281.txt
44 KBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 1Version 1Combined Synopsis/SolicitationArchived
Boiler Inspection and Repairs
- 2Version 2Combined Synopsis/SolicitationArchived
Boiler Inspection and Repairs
- 3Version 3Combined Synopsis/SolicitationArchived
Boiler Inspection and Repairs
- 4Version 4Combined Synopsis/SolicitationArchived
Boiler Inspection and Repairs
- 6Version 6Combined Synopsis/SolicitationArchivedCurrent
Boiler Inspection and Repairs
Similar Opportunities
Title | Phase | Deadline |
|---|---|---|
Additional Details
Solicitation Number
70LCHE26QPFB00004
Archive Date
Sep 26, 2026
Office Address