Notice ID: c3b3cdffd5a5455285dda9229cf65ed1Combined Synopsis/SolicitationArchived
4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe
Archived on October 22, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:00 PM EDT
- Posted
- September 21, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 221310: Water Supply and Irrigation Systems
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250)
- Place of performance
- Department of Veterans Affairs Chillicothe VAMC, Chillicothe, Ohio, 45601
- PSC
- 4610: WATER PURIFICATION EQUIPMENT
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C25026Q1034
- Notice ID
- c3b3cdffd5a5455285dda9229cf65ed1
Description
The purpose of this amendment is to post questions received and provide the facilities responses. The response date and time remain unchanged. Are the 0.2 Micron Filter Cartridges the ones that are for the tank vent filter we would be providing? Or is this for an existing endotoxin filter housing the facility has? 0.2 Micron Filter Cartridges are for bacterial removal from water and to be compatible with housing provided under CLIN 0003. Tank vent cartridges are maintained separately and not within scope. What flow rates do the 60-gallon and 160-gallon storage tank loop return need to handle? Specifically, when sizing the loop return flow meter we need to ensure it can handle the pump demand. I would assume 20 GPM and 40 GPM based on the UV assembly? Return is being constrained via 3gpm flow control device. Pumps are pressure sensing variable flow rate. Both flow control and pumps are not within scope of the solicitation. UV sized for peak demand. Are there existing pumps within the facility that they are keeping? I do not see a distribution pump mentioned in this bid. Pumps are not within scope. Do you have a list of existing equipment that is being kept for both systems? No What are the distribution loop sizes, loop material and loop length are they existing or is this a new loop? Modifying existing loop. Mixed materials, CPVC and Polypropylene. Loop is approximately 240 LF with mixed sizes of 1 and 1-1/2
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Files (3)
Links (2)
- Department of Veterans Affairwww.va.govPosted
- Department of Veterans Affairswww.va.govPosted
Lifecycle
- 1Version 1Combined Synopsis/SolicitationArchived
4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe
- 3Version 3Combined Synopsis/SolicitationArchivedCurrent
4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe
Similar Opportunities
- H946--Sterile Processing Water Quality Chillicothe VA Medical Center
Department of Veterans Affairs · Posted 09/14/2026
- H946--RO/DI Requirement Dayton - Services
Department of Veterans Affairs · Posted 09/03/2026
- H946--Sterile Processing Water Quality Chillicothe VA Medical Center
Department of Veterans Affairs · Posted 08/27/2026
- FA8601 - Industrial Water Treatment at Wright-Patterson AFB
Department of War · Posted 10/08/2026
- Saratoga National Cemetery is in need of Water Testing Services, which involves the collection and testing of water to maintain Government owned Water Purification System. -- H246
Department of Veterans Affairs · Posted 03/31/2023
Additional Details
Solicitation Number
36C25026Q1034
Archive Date
Oct 22, 2026
Office Address
DAYTON, OH, 45428