GovChime
Notice ID: c3b3cdffd5a5455285dda9229cf65ed1Combined Synopsis/SolicitationArchived

4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe

Archived on October 22, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM EDT
Posted
September 21, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
221310: Water Supply and Irrigation Systems
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Place of performance
Department of Veterans Affairs Chillicothe VAMC, Chillicothe, Ohio, 45601
PSC
4610: WATER PURIFICATION EQUIPMENT
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25026Q1034
Notice ID
c3b3cdffd5a5455285dda9229cf65ed1

Description

The purpose of this amendment is to post questions received and provide the facilities responses. The response date and time remain unchanged. Are the 0.2 Micron Filter Cartridges the ones that are for the tank vent filter we would be providing? Or is this for an existing endotoxin filter housing the facility has? 0.2 Micron Filter Cartridges are for bacterial removal from water and to be compatible with housing provided under CLIN 0003. Tank vent cartridges are maintained separately and not within scope. What flow rates do the 60-gallon and 160-gallon storage tank loop return need to handle? Specifically, when sizing the loop return flow meter we need to ensure it can handle the pump demand. I would assume 20 GPM and 40 GPM based on the UV assembly? Return is being constrained via 3gpm flow control device. Pumps are pressure sensing variable flow rate. Both flow control and pumps are not within scope of the solicitation. UV sized for peak demand. Are there existing pumps within the facility that they are keeping? I do not see a distribution pump mentioned in this bid. Pumps are not within scope. Do you have a list of existing equipment that is being kept for both systems? No What are the distribution loop sizes, loop material and loop length are they existing or is this a new loop? Modifying existing loop. Mixed materials, CPVC and Polypropylene. Loop is approximately 240 LF with mixed sizes of 1 and 1-1/2

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Christopher A. Callihan
Contracting Officer
Fax: N/A

Documents

Files (3)

  • 36C25026Q1034_1.docx

    17 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • OPPORTUNITIES-DESCRIPTION 02.docx

    69 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 36C25026Q1034.docx

    19 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe

    Notice b905cf614082406184365d110a5e3e2e on SAM.gov

  2. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe

    Notice c3b3cdffd5a5455285dda9229cf65ed1 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C25026Q1034

Archive Date

Oct 22, 2026

Office Address

DAYTON, OH, 45428