H165--Annual Medical Gas-Testing Certification
Awarded on April 8, 2026. Full description on SAM.gov.
Overview
- Posted
- April 8, 2026
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- NAICS
- 541380: Testing Laboratories and Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262)
- Place of performance
- Phoenix VA Medical Center, Phoenix, AZ, 85012
- Last updated
- Nov 1, 2026
- First published
- Last updated on SAM.gov
- Award date
- Apr 8, 2026
- Award amount (SAM.gov award notice)
- $14.0K
Identifiers
- Solicitation number
- 36C26226Q0387
- Notice ID
- be2fedd026cb407eb9e5ffb423e3049b
- Award number (PIID)
- 36C26226C0169
Description
Award Overview
Award Number
36C26226C0169
Award Amount (SAM.gov award notice)
$14.0K
Award Date
Apr 8, 2026
Awardee
Awardee UEI
U3EKZYJDLWK3
Awardee CAGE Code
7W9Y9
Awardee Address
MANHASSET, NY 11030, NY
Line Item Number
5
Original Solicitation
Notice ID: be2fedd026cb407eb9e5ffb423e3049b
Posted Date: Apr 8, 2026
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $11.3KSigned Oct 29, 2026
- $218.5KSigned Oct 14, 2026
- $282.6KSigned Oct 7, 2026
- $218.5KSigned Oct 1, 2026
- $312.0KSigned Oct 1, 2026
Contacts
Contracting Officer
Primary Contact
Documents
Files (8)
- Download
36C26226Q0387 0003.docx
47 KBAdded in Solicitation version 8Posted - Download
36C26226Q0387 0002.docx
26 KBAdded in Solicitation version 3Posted - Download
36C26226Q0387 0001.docx
25 KBAdded in Solicitation version 2Posted - Download
VA10091 Vendor Request Form.pdf
115 KBAdded in Solicitation version 2Posted - Download
FMS Vendor File Update Request Form.pdf
255 KBAdded in Solicitation version 2Posted - Download
W9 Request for Taxpayer Identification Number and Certification.pdf
138 KBAdded in Solicitation version 2Posted - Download
36C26226C0169_1.docx
23 KBAdded in Award Notice version 4Posted - Download
36C26226Q0387_2.docx
145 KBAdded in Solicitation version 2Posted
Lifecycle
- 5Version 5SolicitationArchived
H165--Annual Medical Gas-Testing Certification
- 4Version 4Award NoticeArchivedCurrent
Type changed from Solicitation to Award Notice
H165--Annual Medical Gas-Testing Certification
Other notices for this solicitation
- Market ResearchRelated noticeFeb 19, 2026
H165--Annual Medical Gas-Testing Certification
- Pre-SolicitationRelated noticeFeb 25, 2026
H165--Annual Medical Gas-Testing Certification
- SolicitationRelated noticeFeb 27, 2026
H165--Annual Medical Gas-Testing Certification
- SolicitationRelated noticeMar 2, 2026
H165--Annual Medical Gas-Testing Certification
- SolicitationRelated noticeMar 9, 2026
H165--Annual Medical Gas-Testing Certification
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made. | 74% | Combined Synopsis | 11/12/2026 |
The purpose of this amendment is to upload the Limitations on Subcontracting form that must be completed and submitted with all quotes. | 61% | Combined Synopsis | 09/18/2026 |
58% | Awarded | Open | |
Amendment 1 See SF 30, Continuation Pages and attachements. | 54% | Solicitation | 10/27/2026 |
1. PURPOSE The Department of Veterans Affairs (VA) is conducting market research to identify qualified and interested firms capable of providing routine and surge Heterotrophic Plate Count (HPC) testing of potable waterlines at VA facilities along the Gulf Coast. The Government seeks capability statements from Small Businesses (including SDVOSB/VOSB) and other than small businesses, and from GSA Multiple Award Schedule (MAS) holders under SIN 541380 (Testing Laboratory Services). This RFI/Sources Sought Notice (SSN) is issued solely for information and planning purposes and does not obligate the Government to award a contract. 2. BACKGROUND & REGULATORY CONTEXT HPC (Standard Methods 9215) estimates live culturable heterotrophic microorganisms in water and is used to monitor premise plumbing microbiological condition; consistent method/media selection is essential to preserve trend comparability. Short, strict hold times for HPC samples require reliable local logistics (cooling/transport and initiation of analysis within program limits—commonly ≤24 hours, and in some jurisdictions ≤8 hours for compliance). In healthcare settings, CDC expects facilities to operate comprehensive water management programs; EPA notes HPC can indicate general distribution-system water quality status, and ≤500 CFU/mL is used for disinfectant-residual equivalency under SWTR. 3. DRAFT SCOPE OF WORK (SUMMARY) 3.1 Methods Contractor shall perform HPC under Standard Methods (SM) 9215 using acceptable variants (e.g., 9215B, 9215D/R2A, 9215E). Contractor shall document media, incubation temperature, and duration for each sample; the selected method/media shall remain consistent throughout the period of performance for comparability of trends. 3.2 Certifications & Accreditation Contractor shall hold current state certification/accreditation explicitly listing HPC under SM 9215 for the place(s) of performance (e.g., MSDH Drinking Water Laboratory Certification in Mississippi; Florida DOH/NELAP in Florida); ISO/IEC 17025 accreditation covering HPC is preferred. Copies of certificates and scopes must be provided. 3.3 Sample Handling & Logistics Contractor shall provide sampling containers, labels, chain‑of‑custody (COC) forms, coolers, and transport ice/ice packs; maintain 0–10 °C during transport; prevent freezing. Contractor shall initiate HPC analysis within applicable program hold times and in no case exceed 24 hours from collection unless stricter state limits are applicable. 3.4 Turnaround & Reporting Standard reporting shall be provided within 48 hours of laboratory receipt. Per‑sample reports must include sample ID/location, collection and receipt timestamps, method/media/incubation conditions, HPC result in CFU/mL, and QC/batch identifiers. Contractor shall flag and notify the COR for any sample exceeding 500 CFU/mL and provide interpretive notes consistent with EPA guidance. 3.5 Emergency/Surge Capability Contractor shall provide rapid response capability for urgent events (e.g., main breaks, disinfection upsets) and identify surge capacity (peak samples/day) to meet VA needs. 4. ACQUISITION PATHWAYS & MANDATORY SOURCES The Government anticipates competing this requirement via Open Market or GSA MAS SIN 541380 if available. Nothing in this RFI commits the Government to a particular path. 5. SMALL BUSINESS & VETERANS FIRST VA will consider the results of this market research to determine small business set‑asides and/or the use of Veterans First authorities. SDVOSB/VOSB respondents should indicate VetCert verification status. Any decision to set aside or use VAAR Subpart 819.70 sole‑source authorities (≤$5M) will be made at the Government’s discretion and in the best interest of the Government based on market research outcomes. 6. WHAT TO SUBMIT (Capability Statement – 10 pages max) A. Firm Information: Legal name, UEI, CAGE, business size/status (SB, SDVOSB, VOSB, HUBZone, WOSB), primary NAICS (541380) and any relevant NAICS. B. MAS Information (if applicable): GSA MAS contract number; confirmation of SIN 541380 listing; link to eLibrary T&Cs/price list. C. Certifications: Current state certification/accreditation scopes explicitly listing SM 9215 HPC (e.g., MSDH, FL DOH/NELAP) and ISO/IEC 17025 scope (if held). Attach certificates/scopes. D. Methods: Identify SM 9215 variant(s) used (B/D/R2A/E) and your approach to method/media consistency for trend comparability. E. Logistics & TAT: Confirm ability to meet hold‑time limits (≤24 h minimum; stricter limits prevail) and report within ≤48 h; describe courier coverage, latest daily lab receipt times, and COC controls. F. QA/QC: Proficiency testing participation, batch QC practices, and LIMS/portal capabilities for electronic reporting. G. Past Performance: Healthcare water microbiology clients (VA/DoD/hospitals). Provide references (optional). H. Pricing (Non‑binding for planning): Rough order‑of‑magnitude per‑sample pricing; field collection fees; surge/expedite rates. 7. GOVERNMENT FURNISHED INFORMATION With any future solicitation, the Government may furnish sampling maps, historical HPC data for trend continuity, and site points of contact. (Not provided at the RFI stage.) 8. Instructions and Response Guidelines: Sources Sought responses are due by September 23, 2026 at 10:00 am (CST) via email to anthony.marion2.gov. All Questions shall be submitted by September 17, 2026 at 10:00 pm (CST) via email to anthony.marion2.gov. Telephone requests or inquires will not be accepted. Public Information will not be provided and shall be utilized to the full extent possible. This a New Requirement. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract. If a solicitation is released, it will be synopsized on Contracting Opportunities (https://beta.sam.gov/) website or GSA. It is the responsibility of the interested parties to monitor these sites for additional information pertaining to this Sources Sought, or future RFP/RFQ. 9. DISCLAIMER This RFI is not a request for proposals or quotations. The Government will not reimburse costs incurred for responding. The Government reserves the right to use information provided to inform the acquisition strategy. If a solicitation is issued, it will be posted separately on SAM.gov. | 54% | Market Research | 09/25/2026 |
Additional Details
Solicitation Number
36C26226Q0387
Archive Date
Apr 13, 2026
Office Address
Gilbert, AZ, 85297