Z--HVAC REFURBISHMENT CU-9_NHOTIC for the BLM Vale Di
Awarded on September 22, 2026. Full description on SAM.gov.
Overview
- Posted
- September 22, 2026
- Notice type
- Award Notice
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of the InteriorBUREAU OF LAND MANAGEMENT
Notice details
- Office
- OREGON STATE OFFICE
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
- Award date
- Sep 22, 2026
- Award amount (SAM.gov award notice)
- $84.6K
Identifiers
- Solicitation number
- 140L4326R0032
- Notice ID
- 74e0b50f3f694ddb9ed1333a8abc6051
- Award number (PIID)
- 140L4326P0148
Description
Award Overview
Award Number
140L4326P0148
Award Amount (SAM.gov award notice)
$84.6K
Award Date
Sep 22, 2026
Awardee
Awardee UEI
KKGZHGB44RF3
Awardee CAGE Code
914P1
Awardee Address
33786 SANTIAM HWY, Lebanon, OR 97355, UNITED STATES
Original Solicitation
Notice ID: 74e0b50f3f694ddb9ed1333a8abc6051
Posted Date: Sep 22, 2026
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $61.9KSigned Sep 22, 2026
- $31.2KSigned Jun 17, 2026
- $3.1MSigned May 22, 2026
- $22.1KSigned May 4, 2026
- $2.6MSigned Mar 30, 2026
Contacts
Contracting Officer
Primary Contact
Documents
Files (16)
- Download
Sol_140L4326R0032_Amd_0002.pdf
202 KBAdded in Combined Synopsis/Solicitation version 5Posted - Download
Attach_2_Contractor_Questions_and_Answers_2pgs_0002.pdf
104 KBAdded in Combined Synopsis/Solicitation version 5Posted - Download
Attach_3_Revised_RFP_Amend2_140L4326R0032_47pgs_0002.pdf
15 MBAdded in Combined Synopsis/Solicitation version 5Posted - Download
Attach_1_Site_Visit_Attendance_Record_1pg_0002.pdf
360 KBAdded in Combined Synopsis/Solicitation version 5Posted - Download
Attach_4_Revised_Specifications_4pgs_0002.pdf
150 KBAdded in Combined Synopsis/Solicitation version 5Posted - Download
Attach_5_Additional_Clause_and_Provision_Option_Item_1pg_0002.pdf
103 KBAdded in Combined Synopsis/Solicitation version 5Posted - Download
B09_Amend_2_SF30_140L4326R0032_0002.pdf
353 KBAdded in Combined Synopsis/Solicitation version 5Posted - Download
Sol_140L4326R0032_Amd_0001.pdf
202 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
B09_Amend_1_Sol_140L4326R0032_0001.pdf
1.3 MBAdded in Combined Synopsis/Solicitation version 2Posted - Download
Sol_140L4326R0032.pdf
281 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
B08_RFP_140L4326R0032_HVAC_Refurbishment_CU-9_(2).pdf
1.2 MBAdded in Combined Synopsis/Solicitation version 1Posted - Download
B01_Synopsis_HVAC_Refurbishment_CU-9.pdf
52 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
B08_Sect_C_attach1_Specifications_4pgs.pdf
119 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
B08_Sect_C_attach2_Map_1pg.pdf
231 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
B08_Sect_C_attach3_Floor_Plan_Drawing_1pg.pdf
72 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
B08_Sect_J_attach4_CWD_OR20260002_5pgs.pdf
1.6 MBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 3Version 3Combined Synopsis/SolicitationArchived
Z--HVAC REFURBISHMENT CU-9_NHOTIC
- 5Version 5Award NoticeArchivedCurrent
Type changed from Combined Synopsis/Solicitation to Award Notice
Z--HVAC REFURBISHMENT CU-9_NHOTIC for the BLM Vale Di
Other notices for this solicitation
- Combined SynopsisRelated noticeAug 19, 2026
HVAC REFURBISHMENT CU-9_NHOTIC
- Combined SynopsisRelated noticeAug 20, 2026
Z--HVAC REFURBISHMENT CU-9_NHOTIC
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
NHOTIC AV SYSTEM REPLACEMENT | - | Solicitation | 11/20/2026 |
Solicitation number 1240BE27Q0018 is issued as a Request for Quotation (RFQ) for the replacement of an existing 3-ton packaged heat pump system with a new, high efficiency ENERGY STAR certified unit that also satisfies FEMP federal purchasing requirements for energy consuming products. The unit serves the Laboratory at the Santee Experimental Forest located at 3734 SC-402, Cordesville, SC 29434. Please see attached solicitation and supporting documents for a full description of the requirement. | - | Combined Synopsis | 11/24/2026 |
11/05/2026: Amendment 1 is attached. 10/29/2026: The solicitation with specifications and the drawings are attached. 10/30/2026: PIEE may label additional documents posted to this solicitation as amendments, even when those documents do not amend the solicitation. Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence, not the PIEE system label to distinguish formal solicitation amendments from other posted documents. The drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access. In accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information. To request access to the CUI solicitation documents, interested offerors shall: 1. Be registered in PIEE. 2. Provide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE. 3. Request access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate. | - | Solicitation | 12/28/2026 |
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. Solicitation number 1240BJ27Q0006 is issued as a Request for Quotation (RFQ) for the replacement of the HVAC system at the Tonasket Ranger Station. This will not be an HVAC replacement in-kind for the existing system. The replacement HVAC system shall be designed and installed based upon consideration of current energy standards. Work includes removal of existing HVAC equipment, delegated design, and installation of new HVAC equipment. This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220 Plumbing, Heating, and Air-Conditioning Contractors The small business size standard is $19,000,000.00 This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency. Location: The Tonasket Ranger Station Office Building 2007 is located at street address: 1 W Winesap St, Tonasket, Washington 98855. | - | Combined Synopsis | 12/03/2026 |
NOTICE OF SOLICITATION NUMBER CHANGE The solicitation number for the John Day Powerhouse HVAC Upgrades has changed from W9127N26BA006 to W9127N27BA007 due to the fiscal-year transition. This is the same acquisition previously announced here under presolicitation notice number W9127N26BA006. Here is a link to the presolicitation notice under the new number W9127N27BA007: https://sam.gov/workspace/contract/opp/61ff2d54f9114299950236018dce1902/view The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for HVAC upgrades at the John Day Dam (JDA) Powerhouse. JDA is approximately 109 miles east of Portland, Oregon, and 275 miles from Seattle, Washington. JDA spans two states, with Units 1–14 located in Sherman County, Oregon, and Units 15–16 in Klickitat County, Washington. Cybersecurity Maturity Model Certification (CMMC). This solicitation requires the contractor and/or subcontractor(s) information system to process, store, or transmit Federal Contract Information (FCI) or Controlled Unclassified Information (CUI), and requires the contractor and/or subcontractor(s) to comply with CMMC requirements. The CMMC level required by this solicitation is: CMMC Level 2 (Self). This CMMC level, or higher, is a condition of award. Prior to award, the apparent successful offeror must have a current CMMC status at Level 2 (Self), or higher, posted in SPRS for each relevant CMMC UID in order to remain eligible for award; failure to meet this requirement will render the offeror ineligible for contract award. CMMC requirements apply to prime contractors and subcontractors throughout the supply chain at all tiers that will process, store, or transmit any FCI or CUI on contractor information systems in the performance of this DoD contract or subcontract. Prime contractors shall comply and shall require subcontractors to comply with and to flow down CMMC requirements, such that compliance will be required throughout the supply chain at all tiers with the applicable CMMC level and assessment type for each subcontract as follows: If a subcontractor will only process, store, or transmit FCI (and not CUI) in performance of the subcontract, then a CMMC status of Level 1 (Self) is required for that subcontractor. If a subcontractor will process, store, or transmit CUI in performance of the subcontract, then a CMMC status of Level 2 (Self), or higher, is required for that subcontractor, and must be current in SPRS prior to subcontract award. Prime contractors are responsible for ensuring that all covered subcontractors obtain and maintain the appropriate CMMC level and assessment type for the information they will process, store, or transmit during performance. For this solicitation, contractors requesting access to documents containing FCI or CUI must have an active SAM registration and a current NIST SP 800‑171 assessment with at least a Basic confidence level recorded in SPRS. Summary of Work: Work includes but is not limited to the following: Complete replacement of the primary and installation of secondary chillers on two chilled water loops serving the majority of the Powerhouse galleries. Demolition and removal of the existing system and installation of four new chiller skid packages totaling approximately 600 tons of refrigeration capacity. New electrical feeds, chilled water pumps, piping, and air handler units, with selective reuse of existing components. Systems must be integrated into a new automated digital HVAC control system. Half of the new systems will be water-cooled; half will be converted to air-cooled. For the air-cooled units, roof-mounted air-cooled condensers will be installed, requiring roof penetrations, piping, and building modifications. HVAC upgrades include new intake and exhaust ducting to prevent smoke propagation through the building in the event of fire, and fire protection measures at all penetrations. HVAC and the building fire protection systems must be fully integrated, replacing all existing pneumatic controls with an integrated digital control system which is capable of functioning to selectively shut down the HVAC to isolate sectors in the event of a fire or smoke event. The work includes mechanical and controls provisions for free cooling using passive outside air during cold nights and modifications to existing intakes, louvers, and penetrations to support smoke ventilation. Localized HVAC units such as mini-splits will be installed for specific spaces, with new electrical supplies, piping, insulation, penetrations, and data reporting to the central HVAC control system. Work will be performed in an active, operational Powerhouse with 6000A, 13.8kV busbars and other heavy electrical equipment, including areas below headwater with nuisance water intrusion risks. Certain pumps must remain operational throughout construction, presenting noise and safety hazards that must be managed. The existing fire suppression system must remain active during construction and be recommissioned upon project completion. Work includes ductwork installation and protection of floor penetrations in close proximity to operational high-voltage electrical busbars, emphasizing strict delineation and safety control of work areas. New systems to be installed must not use refrigerants subject to future refrigerant phase-out schedules (no refrigerant subject to phase-out at any point in the future may be used). Work includes extensive structural penetrations and modifications to support permanent equipment installation including piping, ductwork and new condensing systems. Asbestos abatement and lead mitigation may be required. The anticipated completion date for physical construction is 1,004 calendar days after receiving the Notice to Proceed. The solicitation will be issued as an Invitation for Bids (IFB). This acquisition will result in a single firm-fixed-price contract. The estimated magnitude of construction is between $25M and $100M. This procurement is unrestricted/full and open competition. The North American Industry Classification System (NAICS) code for this action is 238220; Plumbing, Heating, and Air-Conditioning Contractors with a small business size standard of $19M. One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements. This synopsis is not a request for quotes (RFQ), proposals (RFP), or in an invitation for bids (IFB). This is a pre-solicitation notice indicating that a solicitation for a competitive acquisition for the award of one firm-fixed-price contract is intended to be issued via Contract Opportunities at SAM.gov. The tentative solicitation issuance date is October 2026. The solicitation will not be issued less than 15 days from the date of this notice. The specifications and drawings will be included with the solicitation once issued. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Bids will be due not less than 30 days from the date the solicitation is issued. The definitive bid due date and time will be stated in the solicitation and any associated amendments that may be issued. Contractors are responsible for checking this page for any update(s) to this notice. Pursuant to Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) 4.203-1 (b), firms must be System for Award Management (SAM) registered at the time their bid is submitted. Bids from firms that have not registered or completed their online representations and certifications may be rejected. The initial registration process in SAM may take several weeks. Registration instructions may be obtained, and online registration may be accomplished, at www.SAM.gov | - | Pre-Solicitation | Open |
Additional Details
Solicitation Number
140L4326R0032
Archive Date
Oct 7, 2026
Office Address
PORTLAND, OR, 97204