Notice ID: 339ab2b88d2a4892bef41c598a0fbde6Sources SoughtArchived
6515--Patient Transfer Chairs FSS Pre-Solicitation Sources Saught Brand Name or Equal
Archived on July 31, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM EDT
- Posted
- July 15, 2026
- Notice type
- Sources Sought
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 248-NETWORK CONTRACT OFFICE 8 (36C248)
- Place of performance
- C.W. Bill Young Veterans Medical Center, Bay Pines, Florida, 33578
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24826Q0930
- Notice ID
- 339ab2b88d2a4892bef41c598a0fbde6
Description
Good day, SDVOSB s, VOSB s & SB's FSS Pre-Solicitation Sources Sought This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SB and large businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if no or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Please direct reply in the affirmative via email if you are interested and can provide the required product/service for this requirement. Please provide your capability statement, and letter of authorized supply and distribution and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of August 2026 14:00, thanks. GENERAL: C.W. Bill Young VA Medical Center Veterans Hospital, 10,000 Bay Pines Blvd Bay Pines, FL  33744, has a requirement for a new Raizer II Battery Mobile Lifting Chair Name Brand or Equal, and slings for patient lifts. BACKGROUND: Outpatient clinics frequently experience patient falls involving individuals who cannot independently stand but are otherwise medically stable. Staff rely on manual lifting techniques that place them at high risk for injury and violate SPHM principles. This provides a controlled, mechanical method to raise a fallen patient from the floor to a seated position without manual lifting. Fall recovery in CBOCS involves nursing assisting the veteran to a standing position or calling 911. Some patients just want nurses to assist them into a standing position after they have been cleared to get up. When staff allow a veteran to pull them on, we cannot control how much weight they are putting on staff. Fall recovery is mandated by Directive 1611 to have equipment. CBOCs do not have fall recovery equipment because they do not have the space. They need a recovery chair that is low profile. The raiser chair was chosen after market research was completed. The Raizer Lifting Chair will allow staff to get veterans up in a timely fashion, reduce potential for injury to veterans and staff and is small and compact and easy to store in the CBOC locations including Lee County PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: Raizer II Battery Mobile Lifting Chair Name Brand or Equal Lithium Ion Battery Requires only 1 caregiver Lifts in 20-30 seconds Includes a transport bag 300lb minimum lift capacity Rechargeable Charger: 12 V Battery indicator on panel Sound and light indicator for assembly Safe Working Load (SWL) (Maximum total load 150KG) Seat Width 25.7 cm- 27 inches No foam seats Number of lifts on a single charge- Minimum 75 Aluminum frame .FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Fall recovery devices that help lift a fallen person off the floor safely. Equipment must provide the functional and performance capability as listed above in section in above. TRAINING: Contractor is to provide required training at installation of equipment (if applicable) and support for additional training as needed to VA staff. Government will not require additional training. Safe Patient Handling and Mobility Program Manager will then train staff at each CBOC location. WARRANTY OF EQUIPMENT: 1-5-year maintenance warranty
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Vendor
OLYMPUS AMERICA INCContract end date
Sep 30, 2027
NAICS
334510
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Files (2)
Links (1)
- Department of Veterans Affairswww.va.govPosted
Lifecycle
- 1Version 1Sources SoughtArchived
6515--Patient Transfer Chairs FSS Pre-Solicitation Sources Saught Brand Name or Equal
- 3Version 3Sources SoughtArchivedCurrent
6515--Patient Transfer Chairs FSS Pre-Solicitation Sources Saught Brand Name or Equal
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
36C24826Q0930
Archive Date
Jul 31, 2026
Office Address
TAMPA, FL, 33637