GovChime
Notice ID: 13fb6354f0134d7e9427a6319bd247b1Solicitation

COOP House Furnace Replacement at West Fork Lake

Responses closed . Full description on SAM.gov.

Overview

Response deadline
10:00 AM EDT
Posted
September 8, 2026
Notice type
Solicitation
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of WarDepartment of the Army

Notice details

Office
US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION GREAT LAKES AND OHIO.ENDIST LOUISVILLE.W072 ENDIST LOUISVILLE
Place of performance
10558 MCKELVEN ROAD, Cincinnati, Ohio, 45240
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912QR26QA092
Notice ID
13fb6354f0134d7e9427a6319bd247b1

Description

This Request for Quote (RFQ) is for the contractor shall provide all labor, materials, equipment, and services necessary to remove the existing HVAC equipment and install a new 4-ton variable speed heat pump, air handler, and electric heat kit at the project location. All work shall be performed in strict compliance with the attached specifications and all other terms, clauses, and conditions incorporated herein. Quotes are due on 3 September 2026 at 10:00 AM Eastern Time.NOTE: THIS RFQ IS 100% SET ASIDE FOR SMALL BUSINESS. The NAICS code for this procurement is 238220. The size standard is $19M.The solicitation will be available on the web only. Telephone and Fax requests for this solicitation will not be honored. Project files are Portable Document Format (PDF) files and can view, navigated, or printed using Adobe Acrobat Reader. To download the solicitation for this project, contractors are required to register at the Federal Business Opportunities. Amendments will be available from the beta.sam.gov website by download only. Prior to submission of quotes all contractors must have an active registration in the System for Award Management (SAM) database. To register or update information go to http://www.SAM.gov. Questions may be addressed to adyson.medley@usace.army.mil. This announcement serves as the advance notice.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Solicitation

    COOP House Furnace Replacement at West Fork Lake

    Notice d454a10374cf49589805bb9cc7a00180 on SAM.gov

  2. 2
    Version 2Solicitation

    COOP House Furnace Replacement at West Fork Lake

    Notice 93d978d4b0b548888c1b304088532c63 on SAM.gov

  3. 3
    Version 3Solicitation

    COOP House Furnace Replacement at West Fork Lake

    Notice 0cfc99d6a6d54e9dbe80e0794ae7b20c on SAM.gov

  4. 4
    Version 4Solicitation

    COOP House Furnace Replacement at West Fork Lake

    Notice 286bde1bee724213afbfa2c3a5740622 on SAM.gov

  5. 5
    Version 5SolicitationCurrent

    COOP House Furnace Replacement at West Fork Lake

    Notice 13fb6354f0134d7e9427a6319bd247b1 on SAM.gov

  6. 8
    Version 8Award NoticeArchived

    Type changed from Solicitation to Award Notice

    COOP House Furnace Replacement at West Fork Lake

    Notice 10dd460ef9ee459eb8d5983727173ac8 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
*** Amendment 0006 has been posted. Clauses 252.204-7021 and 252.204-7025 have been removed. *** Amendment 0005 has been posted. Please see the Changed Response date from 19 March 2026 11:00AM EDT to 26 March 2026 11:00AM EDT and Specification changes.*** *** PLEASE NOTE previous Update 0005 was an Administrative update to fix response due date for Amendment 0004. No physical amendment documentation was posted with this update.*** *** Amendment 0004 *** 1. Amendment 4 revises/replaces sections 01 35 43, 01 35 53, 08 71 00, 22 00 00 in their entirety, various Plan Sheets as captured in the Summary of Changes Document, and the period of performance. 2. Changed Response date from 24 February 2026 at 11:00AM EST to 19 March 2026 at 11:00AM EST. *** Amendment 0003*** 1. Section 00 22 00 - Supplementary Instructions- (Procedures for Submittal of Offers and Proposal Evaluation Criteria), is hereby revised as indicated below.a. Requirements related to Paragraph 8.6 (Tab F - Project Labor Agreement) is hereby removed.2. Clauses 52.222-33 and 52.222-34 have been removed.3. The proposal due date has been extended from 06 February 2026 at 11:00 AM EST to 24 February 2026 at 11:00 AM EST. ***Amendment 0002 1. Changed Response date from 15 January 2026 to 06 February 2026 at 11:00 ET*** Amendment 0001: 1.Changed Response date from 05 January 2026 to 15 January 2026 at 10:00 ET. 2. The Period of Performance changed from 900 Calendar Days to 817 Calendar Days from Issuance of Notice to Proceed. PROJECT TITLE: NASIC DISTRICT COOLING PLANT AT WRIGHT PATTERSON AIR FORCE BASE, OHPROJECT LOCATION: WRIGHT PATTERSON AIR FORCE BASE, OHREQUEST FOR PROPOSAL FOR THE DESIGN AND CONSTRUCTION FOR A NASIC DISTRICT COOLING PLANT LOCATED AT WRIGHT PATTERSON AIR FORCE BASE, OH.THE MAGNITUDE OF CONSTRUCTION LISTED IN DFARS 236.204(II) IS BETWEEN $25,000,000.00-$100,000,000.00NAICS CODE 238220. SIZE STANDARD $19,000,000. PLEASE NOTE THAT BUSINESS SIZE IN THE SYSTEM FOR AWARD MANAGEMENT (SAM) IS DETERMINED BY THE NAICS CODE. IF THE VENDOR SIZE IS NOT LISTED CORRECTLY FOR A PARTICULAR NAICS CODE IN SAM, THE BUSINESS WILL BE CONSIDERED OTHER THAN A SMALL BUSINESS.THIS IS A FULL AND OPEN PROCUREMENT. IN ACCORDANCE WITH FEDERAL ACQUISITION REGULATION 19.1307, THIS PROJECT REQUIRES THE HUBZONE 10% PRICE EVALUATION PREFERENCE.PLEASE NOTE: SAM IS COMPLETELY FREE OF CHARGE FOR BOTH REGISTRANTS AND USERS.
-Solicitation03/26/2026
Please review the Market Survey Document within the "attachments" section and complete the required Market Survey Response Form provided within the "links" section. The US Army Corps of Engineers (USACE), Louisville District, is conducting market research to identify potential parties having interest in and capability of performing construction of a new, fully functional, industrial, compressed air plant in the controlled access B18 Complex at Wright-Patterson AFB, including two centrifugal air compressors (4,000 HP), two industrial, natural gas-fired air heaters (18.1 MM BTU/hr / 55 MM BTU/hr), insulated specialty steel distribution piping (schedule 80-120), valves, and all associated controls and monitoring devices, integrated with the existing control system. Based on the responses to this request via the Market Survey Response Form, this requirement may be set-aside for small business (in full or in part) or procured through full and open competition. All Small Business Set-Aside categories will be considered. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluation will be provided to companies regarding their submissions. The Government will consider feedback received in determining if a small business set-aside is appropriate for this requirement. DISCLAIMER: This request for information is for information purposes only; it is not a request for competitive proposals, quotations, or bids. It does not constitute a solicitation and shall not be construed as a commitment by the Government. Responses in any form are not offers and the Government is under no obligation to award a contract as a result of this announcement. No Funds are available to pay for preparation of responses to this announcement. Any information submitted by respondents to the announcement is strictly voluntary and will not be returned to the responder. Incomplete answers in any section or providing information outside the scope of this announcement may remove respondents from the Government's determination of whether to solicit the referenced project on a set-aside basis in accordance with Part 19 of the Federal Acquisition Regulation. Not responding to this notice does not preclude participation in any future request for competitive proposals, quotations, or bids, if any issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry (GPE). It is the responsibility of potential offerors to monitor the GPE for additional information pertaining to this requirement.
-Market Research10/31/2026
Repair Mechanical Systems IDIQ (FY 27-32)
-Solicitation11/12/2026
AHU Pictures and Answers
-Combined Synopsis09/22/2026
Pre-solicitation notice for Chiller Plant Preventative Maintenance at the Richarde L. Roudebush VA Medical Center, 1481 W. 10th Street, Indianapolis, IN 46202.
-Pre-Solicitation08/21/2026

Additional Details

Solicitation Number

W912QR26QA092

Archive Date

Sep 8, 2027

Office Address

LOUISVILLE, KY, 40202-2230