Notice ID: 1dbab732fc1b42eaa6a5db7b2487db7aSolicitation
26 WPS - WT15754265 - Mini Split Upgrade
Responses closed . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM PDT
- Posted
- August 13, 2026
- Notice type
- Solicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of WarDepartment of the Air Force
Notice details
- Office
- AIR COMBAT COMMAND.FA4861 99 CONS LGC
- Place of performance
- B119, Nellis Air Force Base, NV, 89191
- PSC
- Z2JZ: REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- FA486126Q0018
- Notice ID
- 1dbab732fc1b42eaa6a5db7b2487db7a
Description
Construct and install two maintenance pads to house all condensing units and provide single line as built drawings, install a two sided screen block at the front of the building matching the existing CMU block color and style, use solid and vented CMU blocks to ensure sufficient airflow around all condensing units, and build screen block walls two rows higher than the condensing units; the contractor shall supply a weatherproof 120V maintenance receptacle for each pad, core drill the existing wall of Building 119, install a 3 inch PVC pipe sealed with acoustical seal to maintain ICD 705 compliance per Tech Spec 1.5.1, install insulation on all line sets entering Building 119, run all electrical from Room 119s electrical mechanical room using panel EDH 1 3 rated at 480/277V and 800 amps, tie all new HVAC systems to the existing generator for backup power, surface mount electrical conduits in Room 119 and the exterior HVAC yard, run conduits underground to each maintenance pad, and supply a weatherproof disconnect for each condensing unit; the contractor shall install new cassette type HVAC systems in Rooms 112, 113, 114, and 132 using the existing suspended ceiling grid with added support, provide a 1 ton HVAC system with a separate controller for Room 112, provide 2 ton HVAC systems with separate controllers for Rooms 113 and 114, and provide a 4 ton HVAC system with a separate controller for Room 132; all design and construction shall comply with the current International Building Code, UFC standards, all applicable public laws, executive orders, CFR requirements, DOD instructions and directives, Nellis ID2 standards, and Clark County, Nevada, and federal codes and laws, and any discrepancies between codes or standards and contract documents shall be immediately reported to the Contracting Officer, with the more stringent requirement applying unless otherwise directed. 26 WPS request this HVAC installation and testing be accomplish within, 160 days, period of performance. Proposals will be evaluated using lowest price, technically acceptable. A site visit will take place on 8/4/2026 at 0830 AM PDT, meeting in front of building 119 main entrance. Please ensure your base pass request has been submitted to me by 2PM PDT on 7/24/2026 if you do not have base access to Nellis AFB to ensure you have access by the date of the site visit. Proposals are due by 8/18/2026 at 2:00 PDT. Answers will be provided via a solicitation amendment.
Award Overview
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for FA486126Q0018piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 1Version 1Solicitation
26 WPS - WT15754265 - Mini Split Upgrade
- 2Version 2Solicitation
26 WPS - WT15754265 - Mini Split Upgrade
- 3Version 3Solicitation
26 WPS - WT15754265 - Mini Split Upgrade
- 4Version 4SolicitationCurrent
26 WPS - WT15754265 - Mini Split Upgrade
Similar Opportunities
- 99CES - PKA - WT16747339 - Install Lift Station Disconnect B1730
Department of War · Posted 05/28/2026
- Replace Chiller in Building 418
Department of War · Posted 06/29/2026
- J--E21 PRCA HVAC REPLACEMENT
Department of the Interior · Posted 10/20/2026
- R-410A LEAK DETECTORS (Bldgs 750, 751 & 768)
Department of War · Posted 10/27/2026
- Infrared Radiant Heat Maintenance Services
Department of War · Posted 10/26/2026
Additional Details
Solicitation Number
FA486126Q0018
Archive Date
Aug 13, 2027
Office Address
NELLIS AFB, NV, 89191-7063