GovChime
Notice ID: 565df1f17e664111a9d534c39de0d3e8Combined Synopsis/SolicitationArchived

MOF Elk Lick Dam Decommissioning & Restoration

Archived on September 12, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:00 PM EDT
Posted
August 21, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
237990: Other Heavy and Civil Engineering Construction
Agency
Department of AgricultureFOREST SERVICE

Notice details

Office
USDA-FS, CSA EAST 13
Place of performance
Elkins, West Virginia
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
12445526Q0113
Notice ID
565df1f17e664111a9d534c39de0d3e8

Description

-------------------------------------------------------------------------------

Q&A Memorandum: Uploaded 21 August 2026

-------------------------------------------------------------------------------

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. Solicitation number 12445526Q0113 is issued as a Request for Quotation (RFQ) for MOF Elk Lick Dam Decommissioning & Restoration.


PROJECT SUMMARY: The USFS is pursuing a Purchase Order for decommissioning and restoration construction services on the Monongahela National Forest Elk Lick Dam. Work includes removal of an existing concrete gravity dam and restoration of a stable stream channel through the former reservoir footprint. Services shall be performed by the awardee in accordance with the specifications, terms, and conditions of this solicitation, including those found in the solicitation attachments.


SET-ASIDE: This solicitation is set aside 100% for Small Business entities under NAICS 237990 - Other Heavy and Civil Engineering Construction (Size Standard: $45M).


PROJECT LOCATION: Elk Lick Dam, Monongahela National Forest. See solicitation and its attachments for additional location details.

SOLICITATION POINT OF CONTACT: Matthew (Matt) Killian, Contracting Officer matthew.killian@usda.gov

SITE VISIT INFORMATION:


A site visit will be held at 9:30 AM EDT on Tuesdsay, 11 August 2026.


Site Visit Meet-up Coordinates:

39.061205, -79.668473


To attend the site visit, contact the Contracting Officer, Matthew (Matt) Killian, via email at matthew.killian@usda.gov.

PLEASE REVIEW ALL SOLICITATION MATERIALS IN-FULL, INCLUDING ALL INSTRUCTIONS TO OFFERORS, PRIOR TO SUBMITTING A QUOTATION. LATE QUOTATIONS AND/OR QUOTATIONS THAT DO NOT COMPLY WITH SAID INSTRUCTIONS MAY BE DETERMINED NON-REPONSIVE AND ELIMINATED FROM AWARD CONSIDERATION.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Matthew (Matt) Killian

Documents

Files (7)

  • C08_QAmemo-12445526Q0113.pdf

    1007 KBAdded in Combined Synopsis/Solicitation version 5Posted
    Download
  • C04_1-12445526Q0113-Att2-Plans.pdf

    8.7 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • C04_0-RFQ-12445526Q0113.pdf

    1.2 MBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • C04_1-12445526Q0113-Att1-SOW.pdf

    2.0 MBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • C04_1-12445526Q0113-Att3-Specs.pdf

    1019 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • C04_1-12445526Q0113-Att4-DBAWD_WV20260061.pdf

    38 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • C04_1-12445526Q0113-Att5-FillableSOI.xlsx

    17 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    MOF Elk Lick Dam Decommissioning & Restoration

    Notice e972bc87a2124e008b739cee49e3797d on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationArchived

    MOF Elk Lick Dam Decommissioning & Restoration

    Notice 328402d464a949bd8ddfd9a1757d3d62 on SAM.gov

  3. 3
    Version 3Combined Synopsis/SolicitationArchived

    MOF Elk Lick Dam Decommissioning & Restoration

    Notice 8f788bf71d254d89afbaa1da9a60496a on SAM.gov

  4. 5
    Version 5Combined Synopsis/SolicitationArchivedCurrent

    MOF Elk Lick Dam Decommissioning & Restoration

    Notice 565df1f17e664111a9d534c39de0d3e8 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This is a SOURCES SOUGHT SYNOPSIS and is not a solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified Small Business, HUBZone, 8(a), Service Disabled Veteran owned, and Women owned Small Business firms. Responses to this Sources Sought Synopsis will be used by the government in making appropriate acquisition decisions. The intended work falls under NAICS code 237990, Other Heavy and Civil Engineering Construction. The U.S. Army Corps of Engineers, Mobile District, anticipates a requirement for a firm-fixed-price construction contract to perform structural concrete and gate repairs on the spillway at the Carters Reregulation Dam located in Chatsworth, Georgia. The purpose of this project is to perform concrete rehabilitation and retrofit existing structural elements that have been impacted by concrete expansion due to Alkali-Silica Reactivity (ASR). The scope of work includes, but is not limited to: structural concrete demolition of existing pier stoplog slots; installation of new steel stoplog guides and embedded seal plates; placement of specialized shrinkage-compensating concrete; and recessing of side seal plates. Additional mechanical and structural work includes replacing side and bottom seals on four (4) Tainter gates and replacing seals on eight (8) stop logs. The contractor will be fully responsible for the design, fabrication, and installation of Temporary Dewatering Structures (TDS)/cofferdams and temporary gate support shoring. To maintain operational continuity, construction must be executed sequentially, allowing only one gate bay to be dewatered and out of service at any given time. The estimated magnitude of construction is between $5,000,000 and $10,000,000, with an anticipated performance period of approximately 180 calendar days. Responses are requested with the following information, which shall not exceed a total of eight pages. 1. Offeror name, address, points of contact with telephone numbers and e-mail addresses. 2. Business size/classification to include any designations as Small Business, 8(a), HUBZone, Service Disabled Veteran Owned and Women-Owned Small Businesses shall be indicated on first page of submission. 3. Bonding capability: construction bonding level per single contract and aggregate construction bonding level, both expressed in dollars; along with current available bonding capacity. 4. Description of your capability to perform the specialized work described above, manage subcontractors, secure and comply with environmental permits, and safely execute Dam and hydraulic Steel structures (HSS) construction. Specifically address your capacity and proposed approach to designing, fabricating, and installing Temporary Dewatering Structures (TDS) and tainter gate shoring systems. 5. Past performance and experience on up to three (3) projects of similar scope, complexity, and value completed within the past five (5) years, or at least 50% construction complete. Relevant experience includes: structural concrete demolition, specialized concrete placement (such as shrinkage-compensating concrete under strict curing/testing protocols), stainless steel structural embed/guide fabrication and welding, Tainter gate seal replacement, and work with USACE Hydraulic Steel Structures within the civil works branch. For each project, provide the title, location, general description of the scope, contract value, role (Prime or Subcontractor), and client contact information (name, phone, and email). NO RESPONSES WILL BE ACCEPTED BY FAX OR MAIL. ALL RESPONSES MUST BE E-MAILED to: Jeffrey M. Donaldson at Jeffrey.M.Donaldson@usace.army.mil. Submittals are due no later than 20 October 2026 at 2:00 PM CDT. Telephonic responses will not be honored. This is not a Request for Proposal, only a Request for Information. No award will result from this Sources Sought. This notice does not constitute any commitment by the Government.
65%
Market Research10/20/2026
* Bid Abstract uploaded September 21, 2026. * Amendment 0003 - The purpose of this amendment is to make the following changes to the solicitation: SOLICITATION CLOSING DATE The solicitation closing date is hereby extended from Friday, September 18, 2026, at 9:00 PM Pacific Daylight Time (PDT) to Monday, September 21, 2026, at 9:00 AM Pacific Daylight Time (PDT). NEW SOLICITATION CLOSING DATE: Monday, September 21, 2026, at 9:00 AM Pacific Daylight Time (PDT) BID OPENING The bid opening will be conducted on Monday, September 21, 2026, at 10:00 AM Pacific Daylight Time (PDT). Bids received prior to the solicitation closing date and time will be secured and opened at the date and time specified above. Will send TEAMs link once BID is received. *Amendment 0002 - The purpose of this amendment is to make the following changes to the solicitation: 1. Extend the Solicitation Closing Date: The solicitation closing date is hereby extended by one week, from September 11, 2026, to September 18, 2026. 2. Clarify Bidder Inquiry Deadline: The bidder inquiry provision is revised from: No response will be posted to inquiries after Close of Business on the seventh business day preceding the solicitation due date to: The deadline for submission of bidder inquiries is Close of Business on the seventh business day preceding the solicitation due date. Inquiries received after this deadline may not be answered. 3. Add Pertinent Documents/Attachments: The following six (6) documents/attachments are hereby added to the solicitation: A9 - Work Space Access Trailer and Parking Location, A10 - Pump Access, A11 - Propeller Condition, A12 - JDA Fish Pump rehab drawings, A13 - SouthFishwayPumps_OandM Manual, A14 - SouthFishTurbine-Unit3_OandM Manual (all documents previously designated as CUI have been downgraded) 4. Remove Attachment: Attachment AMD0002_Technical Sections.pdf is hereby removed from the solicitation. 5. Revise Specifications: The following revisions are hereby incorporated into the solicitation specifications: File Section Changes Specifications 15 00 00.03 25 Paragraph 1.4.2 is revised to change pump shaft assembly and propeller assembly to vertical shaft assembly. Paragraph 2.1.2 is revised to change pumpshaft to pump propeller. Specifications 01 10 10.00 25 Paragraph 1.6.b is amended to extend the outage window through June 30, 2028.Specifications 09 97 02.00 25 Paragraph 3.5 is amended to include the extension shaft in the painting schedule. All other terms and conditions of the solicitation remain unchanged.*Amendment 0001 - The purpose of this amendment is to extend the solicitation closing date by two weeks from August 28, 2026 to September 11, 2026. All other terms and conditions of the solicitation remain unchanged. PROJECT TITLE: JOHN DAY FISH PUMP REHABILITATION PROJECT LOCATION: JOHN DAY LOCK AND DAM, RUFUS, OR DESCRIPTION: REMOVAL, REFURBISHMENT, AND REPLACEMENT OF MAJOR COMPONENTS OF FISH PUMP UNIT 1, INCLUDING BUT NOT LIMITED TO SHAFTS, BEARINGS, BEARING BRACKETS, AND RIGHT-ANGLE DRIVE GEARBOXES. MAGNITUDE OF CONSTRUCTION: BETWEEN $5,000,000 - $10,000,000 NAICS: 237990 OTHER HEAVY AND CIVIL ENGINEERING CONSTRUCTION SIZE STANDARD: $45,000,000 SOCIO-ECONOMIC CONSIDERATIONS: TOTAL SMALL BUSINESS SET-ASIDE Bid Opening: Monday, September 21st, 2026, at 10:00 AM Pacific Daylight Time (PDT). Will send TEAMs link once BID is received. Due to CMMC access requirements, in order to gain access to CUI attachments, please verify your organization has a minimum CMMC Level 1 Self verification and submit your CMMC Unique Identifier Number and CAGE Code via email to joseph.b.jarvis@usace.army.mil and cory.r.pfenning@usace.army.mil. BIDS DUE: Friday, September 18th, 2026, at 09:00 PM Pacific Daylight Time (PDT). BID OPENING: Monday, September 21st, 2026, at 10:00 AM Pacific Daylight Time (PDT).
65%
Solicitation09/21/2026
Dashields Locks and Dam Install 4 Corner Hydraulics Dashields Locks and Dam, Coraopolis, PennsylvaniaThe Dashields hydraulic system upgrade consists of demolition and removal of the existing hydraulic system and its related components, and installation of a new hydraulic system with supporting controls and buildings.Primary hydraulic system components to be demolished and removed are motors, pumps, reservoir, filters, filter housings, piping and pipe hangers, hydraulic fluid, valves, and manifolds. Any hydraulic piping that is embedded in concrete must be drained, cut flush with the concrete surface, capped or plugged, and abandoned in place. Nine (9) new hydraulic cylinders must be furnished by the contractor and five (5) will be furnished by the government. Electrical demolition work must include but not be limited to removal of specified buckets, cabinet doors, junction boxes, levers, buttons, indicators, limit switches, wiring, and hardware. Some concrete demolition work must be required for placement of new buildings and routing of new electrical cable and mechanical pipe.Three (3) new hydraulic power units (HPUs) must be furnished and installed on the land and middle lock walls inside two new 2-story HPU buildings at locations specified on the contract drawings. The fourth HPU will be furnished and installed on an elevated platform in the river wall at the location specified in the contract drawings. The HPU buildings and elevated platform must be designed and constructed by the contractor in accordance with the performance specification and the concept drawings included in the contract drawings. The HPUs must send hydraulic power to the existing hydraulic cylinders by means of new stainless-steel piping and new manifold mounted hydraulic components.The new hydraulic equipment must be operated by new electronic controls that will be installed inside new panels and new control consoles. The new control panels must be installed on each HPU with an additional control panel inside of the middle wall operations building. The new control consoles must be installed inside three existing and one new 1-story control shelter at locations specified in the contract drawings. The control shelter must be designed and constructed by the contractor in accordance with the performance specification and the concept drawings included in the contractdrawings.New buckets and supporting equipment must be installed inside existing motor control centers (MCCs). New hardware and power and control cabling must be installed as specified and as required for operation of the new electrical/mechanical equipment. Some concrete installation work must be required for placement of new buildings and routing of new electrical cable and mechanical pipe. A geotechnical and civil site analysis must be completed to confirm the structural integrity of all foundations for all new project components and to confirm proper drainage. Minimal new steel grating must be required for placement over top new concrete utility trenches. All new hydraulic and controls equipment must be tested and commissioned prior to project handoff. This project is to be completed at a locks and dam site along the Ohio River and thus requires the use of a floating work plant and work boat(s) for construction. Also, all as-built drawings must be stamped by a registered PE.The work shall be completed within 730 after written Notice to Proceed.The acquisition will be procured as 100% Set-Aside for Small Business. The resulting award will be for one (1) Firm-Fixed-Price (FFP) Contract. All responsible Offerors are encouraged to participate. The Request for Proposal (RFP) will be issued on or about 18 June 2026, online through Procurement Integrated Enterprise Environment (PIEE) which posts the opportunity to SAM.gov; therefore, requests for hardcopies of the solicitation will not be honored.The North American Industrial Classification System (NAICS) Code for this acquisition is 237990 - 0ther Heavy and Civil Engineering Construction.The Small Business Size Standard for this NAICS Code is $45,000,000.00.In order to submit an Offer on this project, your company must-1) Be registered in System for Award Management (SAM) and maintain an active registration status. 2) Be registered in the Procurement Integrated Enterprise Environment (PIEE) for the Solicitation Module with the PROPOSAL MANAGER Manger role. System for Award Management (SAM) RegistrationRegistering in SAM.gov includes both entity validation and entity registration.To register in SAM:a. Navigate to SAM.govb. Select Sign-In (top right)c. Select Create an Account then Follow the Instructions. d. After Account is Set-up, Select Sign In.e. Under the Entity Management widget, Select Get Started button. f. Select Register Entity. As part of entity registration, a Unique Entity ID will be assigned.For Additional Information on SAMTo Register Your Entity (company), please visit https:/www.fsd.gov/gsafsd_sp?id=gsa_index . Here you will find the following, Get Started with Your Registration Check Registration Status ACTIVE, INACTIVE, PENDING Update Your Registration Become an Entity Administrator Validate Your Entity *Access User Guides *By selecting this option, you can obtain a Quick Start Guide for Contract Registrations.Also, here you will find in addition to the User Guides - FAQs, Videos, and Definitions.PLEASE NOTEIt is mandatory that all companies be registered in SAM in order to receive federal contracts.There is no charge to register or maintain your company (entity) registration.Login.gov manages usernames and passwords for SAM.gov. *Important* Registration InformationRegistration can take at least ten (10) business days to be active in SAM.gov.Registration must be in active status upon offer submission and remain active during award period.Registration must be renewed every 365 days to remain active.The Federal Service Desk (FSD) for SAM questions, may be contacted. Phone Number: 866-606-8220Hours of Operation: Monday-Friday 8 a.m. to 8 p.m. ETProcurement Integrated Enterprise Environment (PIEE) Solicitation Module RegistrationTo register for PIEE follow the below instructions. Register in PIEE:a. Navigate to https://piee.eb.mil/b. Select Register [top right]c. Select Vendord. Create a User ID and Password and follow the prompts [next]e. Create Security Questions [next]f. Complete your User Profile Information [next]g. Complete your Supervisor or Approving Official Information [next]h. Complete Rolesi. Step 1. Select SOL-Solicitationii. Step 2. Select Proposal Manageriii. Step 3. Click Add Rolesiv. Step 4. Fill in your Location Code (CAGE Code) [next]i. Provide a justification for your registration [next]j. Follow the remaining prompts to submit your registrationThe Procurement Integrated Enterprise Environment (PIEE) help desk may be reached by calling telephone number 866-618-5988 for assistance. 30 June 2026 - Amendment 0001 issued. 23 July 2026 - Amendment 0002 Issued 31 July 2026 - Amendment 0003 issued. 13 August 2026 - Amendment 0004 issued.
65%
Solicitation08/20/2026
Dashields Locks and Dam Install 4 Corner Hydraulics Dashields Locks and Dam, Coraopolis, PennsylvaniaThe Dashields hydraulic system upgrade consists of demolition and removal of the existing hydraulic system and its related components, and installation of a new hydraulic system with supporting controls and buildings.Primary hydraulic system components to be demolished and removed are motors, pumps, reservoir, filters, filter housings, piping and pipe hangers, hydraulic fluid, valves, and manifolds. Any hydraulic piping that is embedded in concrete must be drained, cut flush with the concrete surface, capped or plugged, and abandoned in place. Nine (9) new hydraulic cylinders must be furnished by the contractor and five (5) will be furnished by the government. Electrical demolition work must include but not be limited to removal of specified buckets, cabinet doors, junction boxes, levers, buttons, indicators, limit switches, wiring, and hardware. Some concrete demolition work must be required for placement of new buildings and routing of new electrical cable and mechanical pipe.Three (3) new hydraulic power units (HPUs) must be furnished and installed on the land and middle lock walls inside two new 2-story HPU buildings at locations specified on the contract drawings. The fourth HPU will be furnished and installed on an elevated platform in the river wall at the location specified in the contract drawings. The HPU buildings and elevated platform must be designed and constructed by the contractor in accordance with the performance specification and the concept drawings included in the contract drawings. The HPUs must send hydraulic power to the existing hydraulic cylinders by means of new stainless-steel piping and new manifold mounted hydraulic components.The new hydraulic equipment must be operated by new electronic controls that will be installed inside new panels and new control consoles. The new control panels must be installed on each HPU with an additional control panel inside of the middle wall operations building. The new control consoles must be installed inside three existing and one new 1-story control shelter at locations specified in the contract drawings. The control shelter must be designed and constructed by the contractor in accordance with the performance specification and the concept drawings included in the contractdrawings.New buckets and supporting equipment must be installed inside existing motor control centers (MCCs). New hardware and power and control cabling must be installed as specified and as required for operation of the new electrical/mechanical equipment. Some concrete installation work must be required for placement of new buildings and routing of new electrical cable and mechanical pipe. A geotechnical and civil site analysis must be completed to confirm the structural integrity of all foundations for all new project components and to confirm proper drainage. Minimal new steel grating must be required for placement over top new concrete utility trenches. All new hydraulic and controls equipment must be tested and commissioned prior to project handoff. This project is to be completed at a locks and dam site along the Ohio River and thus requires the use of a floating work plant and work boat(s) for construction. Also, all as-built drawings must be stamped by a registered PE.The work shall be completed within 730 after written Notice to Proceed.The acquisition will be procured as 100% Set-Aside for Small Business. The resulting award will be for one (1) Firm-Fixed-Price (FFP) Contract. All responsible Offerors are encouraged to participate. The Request for Proposal (RFP) will be issued on or about 18 June 2026, online through Procurement Integrated Enterprise Environment (PIEE) which posts the opportunity to SAM.gov; therefore, requests for hardcopies of the solicitation will not be honored.The North American Industrial Classification System (NAICS) Code for this acquisition is 237990 - 0ther Heavy and Civil Engineering Construction.The Small Business Size Standard for this NAICS Code is $45,000,000.00.In order to submit an Offer on this project, your company must-1) Be registered in System for Award Management (SAM) and maintain an active registration status. 2) Be registered in the Procurement Integrated Enterprise Environment (PIEE) for the Solicitation Module with the PROPOSAL MANAGER Manger role. System for Award Management (SAM) RegistrationRegistering in SAM.gov includes both entity validation and entity registration.To register in SAM:a. Navigate to SAM.govb. Select Sign-In (top right)c. Select Create an Account then Follow the Instructions. d. After Account is Set-up, Select Sign In.e. Under the Entity Management widget, Select ?Get Started? button. f. Select Register Entity. As part of entity registration, a Unique Entity ID will be assigned.For Additional Information on SAMTo Register Your Entity (company), please visit https:/www.fsd.gov/gsafsd_sp?id=gsa_index . Here you will find the following, Get Started with Your Registration Check Registration Status ? ACTIVE, INACTIVE, PENDING Update Your Registration Become an Entity Administrator Validate Your Entity *Access User Guides *By selecting this option, you can obtain a Quick Start Guide for Contract Registrations.Also, here you will find in addition to the User Guides - FAQs, Videos, and Definitions.PLEASE NOTEIt is mandatory that all companies be registered in SAM in order to receive federal contracts.There is no charge to register or maintain your company (entity) registration.Login.gov manages usernames and passwords for SAM.gov. *Important* Registration InformationRegistration can take at least ten (10) business days to be active in SAM.gov.Registration must be in active status upon offer submission and remain active during award period.Registration must be renewed every 365 days to remain active.The Federal Service Desk (FSD) for SAM questions, may be contacted. Phone Number: 866-606-8220Hours of Operation: Monday-Friday 8 a.m. to 8 p.m. ETProcurement Integrated Enterprise Environment (PIEE) Solicitation Module RegistrationTo register for PIEE follow the below instructions. Register in PIEE:a. Navigate to https://piee.eb.mil/b. Select Register [top right]c. Select Vendord. Create a User ID and Password and follow the prompts [next]e. Create Security Questions [next]f. Complete your User Profile Information [next]g. Complete your Supervisor or Approving Official Information [next]h. Complete Rolesi. Step 1. Select SOL-Solicitationii. Step 2. Select Proposal Manageriii. Step 3. Click Add Rolesiv. Step 4. Fill in your Location Code (CAGE Code) [next]i. Provide a justification for your registration [next]j. Follow the remaining prompts to submit your registrationThe Procurement Integrated Enterprise Environment (PIEE) help desk may be reached by calling telephone number 866-618-5988 for assistance.
65%
Pre-Solicitation06/18/2026
Sources Sought Synopsis PROJECT TITLE: Kissimmee River Restoration (KRR) Project, S-69 Weir Repair This is announcement constitutes a Source Sought Synopsis and seeks information from industry which will only be used for preliminary planning purposes. THIS IS NOT A SOLICITATION FOR BIDS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. Respondents will not be notified of the results of the evaluation. The South Atlantic Jacksonville District of the U.S. Army Corps of Engineers (SAJ) is seeking interest from prospective bidders for a potential fiscal year (FY) 2027 contract award for the subject construction project. SAJ has a requirement for the repair of components of the existing S-69 weir structure inclusive of sheet pile’s concrete cap and ancillary concrete driving slab. The purpose of this sources sought is to gauge interest, capabilities, and qualifications of contractors that have experience in completing similar projects. The scope of the contract is inclusive of but not limited to (a) partial concrete cap demolition, (b) inspection and cleaning of existing concrete, steel bars, anchor studs and steel sheet piles, (c) preparation of studs and rebar, (d) installation of new closed-loop epoxy coated stirrups routed through the sheet pile and new anchor studs welded to the sheet pile, (e) provision of new expansion joints, (f) repairing of concrete caps with structural concrete, (g) driving slab subsurface void investigation and subsequent repairs to address separation of the slab from sheet pile, and (h) all quality control and construction administration submittals relevant to the construction effort, including as-builts of the final repaired structure. The proposed project will be a Firm Fixed Price (FFP) contract. The Jacksonville District anticipates the issuance of a Request for Proposal (RFP). No reimbursement will be made for any costs associated with providing information in response to this Sources Sought or any follow-up information requested. DESCRIPTION OF WORK: The S-69 Weir consists of driven sheet pile walls with a concrete cap that acts as a weir and is a key feature of the Kissimmee River Restoration (KRR) Project. Located in Okeechobee and Highlands Counties, Florida, the weir’s primary function is to restore the Kissimmee River’s floodplain hydrology to pre-canal conditions by controlling water stages and discharges into the C-38 canal. Repair of components of the existing S-69 weir structure require sheet pile concrete cap and driving concrete slab. Anticipated work includes but is not limited to: concrete removal portions of the cap, addition of new reinforcement steel closed stirrups, welding of anchor studs, providing expansion joint material, casting-in-place new structural concrete, assessment of voids underneath the driving slab through concrete coring and grouting of cored holes, and filling of gaps between the slab and cap with Controlled Low Strength Material (CSLM) or equivalent approved flowable fill. The overall project site components encompass work to done at the following approximate location: 27.334767, -81.032830; very close to the “Chandler Slough South Trailhead”. Specific project components include the following items and incidental related work; refer to conceptual plans for further information: Concrete Cap Repair 1. Concrete Cap Partial Demolition at Expansion Joints a. At 29 expansion joint locations, demolish 36” of concrete cap on each side of expansion joint. Existing rebar and sheet pile studs to remain. 2. Inspection and Cleaning of Existing Concrete, Steel Bars, Anchor Studs, and Steel Sheet Piles prior to new repair. a. Use blast cleaning techniques for steel. Demolish concrete beyond the 36” footprint if concrete material is weak and unsuitable. 3. Drilling/Burning of holes into sheet pile to allow for closed stirrups to pass through. a. Drill or burn 2-inch diameter holes to allow installation of closed-hoop steel stirrups. 4. Welding of new anchor studs to sheet pile. a. Anchor stud size is 1/2"(diameter) x 4” 5. Preparation of Studs and Rebar (Coating) prior to new repair a. Apply inorganic zinc-based primer for all existing rebar as well as both existing and new studs (coating to be applied after welding). 6. Installation of new #5 closed-loop epoxy-coated stirrups at 6” on-center, with the bottom leg routed through the sheet pile. a. First stirrup must be 3” from expansion joint, all others to follow the spacing requirement. 7. Provision of new expansion joints. a. Expansion joint thickness must be increased to 2”. Use Class 50 system, with ASTM C920 elastomeric sealant rated for at least 50% movement an documented as suitable for the anticipated weather and ultraviolet exposures, temperature range, and substrate conditions. 8. Repair of concrete cap using structural cast-in-place concrete (f’c = 4,500 psi). a. Concrete quality, placement, consolidation, and curing procedures per plans and specifications will be strictly monitored by both Contractor QC and Government QA personnel. Ancillary North Driving Slab Repair 1. Coring layout and investigation of potential subsurface voids a. Core drill 20 cores into the slab from approximately STA 23+80 to 25+20 (centered about the primary area of concern near STA 24+50). Cores will be spaced at approximately 20-foot intervals and positions 2 to 5 feet from the inner wall to characterize conditions directly adjacent to the gap. Core drill new cores spaced at approximately 40-foot intervals along the remainder of the Northern leg. b. Investigate cored areas for voids underneath the slabs. Coordinate with the Government for any adverse conditions found. c. Fill all core holes with non-shrink grout after Government inspection. 2. Repair of separated slab at North leg of weir. a. The 3-inch separation as indicated in concept drawings and all other voids must be filled with Controlled Low Strength Material (CLSM) or an approved flowable fill. 3. Repair of slab’s expansion joints a. Expansion joints of the driving slab must be mechanically routed or scraped out, joint faces cleaned and prepared, new closed-cell backer rod installed to achieve the proper depth-to-width ration, and heavy-duty, UB-resistant elastomeric joint sealant applied. Construction Submittals and As-Builts 1. Providing quality control and all required submittals during construction, which includes but is not limited to, the void investigation report, concrete mix design, and all product data. 2. Providing as-built documentation once repair is completed. ROUGH ORDER OF MAGNITUDE: $500,000 to $1,000,000 PRODUCT SERVICE CODE: Z2KA – REPAIR OR ALTERATION OF DAMS NAICS CODE: The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 237990 - Other Heavy and Civil Engineering Construction. SMALL BUSINESS SIZE STANDARD: $45,000,000 The anticipated period of performance is 90 calendar days after receipt of the Notice to Proceed (NTP). SUBMISSION REQUIREMENTS: Responses to this Sources Sought shall be limited to 5 pages and shall include the following information: 1. Company/Contractor name, address, point of contact, phone number and e-mail address. 2. Company’s interest in bidding on the subject requirement when issued. 3. Company’s capability to perform a work of this magnitude and complexity (include company’s capability to execute comparable work performed within the past 10 years), within an area of similar remoteness. Company should provide at least 3 examples which, at a minimum, include the following: a. Brief description of the project b. Customer name c. Customer satisfaction d. Timeliness of performance e. Dollar value of the completed projects 4. Offeror shall identify their Small Business classification and Small Business Size: a. Small Business b. Small Disadvantage Business c. 8(a) Small Business d. HUBZone e. SDVOSB f. WOSB 5. If significant subcontracting or teaming is anticipated in order to deliver technical capability, firms should address the structure of such arrangement include Joint Venture information, if applicable – existing and potential. 6. Bonding Capacity (construction bonding level per contract and aggregate construction bonding level, both expressed in dollars) via letter from the bonding company. NOTES: DO NOT SUBMIT A RESPONSE TO THIS SOURCES SOUGHT IF YOU DO NOT INTEND TO BID ON THIS PROJECT. DO NOT SUBMIT PROPRIETARY AND/OR BUSINESS CONFIDENITAL DATA. SUBMISSION INSTRUCTIONS: Interested parties who consider themselves qualified to perform the work associated with the subject requirement, are invited to submit a response to this Sources Sought Notice no later than November 09, 2026, at 10:00 AM, EST. All responses under this Sources Sought Notice shall be sent to Ms. Tedra Thompson via email at tedra.n.thompson@usace.army.mil and Mr. William Wallace via email at: william.j.wallace@usace.army.mil. Prior Government contract work is not required for submitting a response under this sources sought synopsis. You must be registered in the System for Award Management (SAM), in order to be eligible to receive an award from any Government solicitation. To register, go to www.sam.gov. For additional information visit the website for the Federal Service Desk (www.FSD.gov) which supports SAM or contact them at 866-606-8220 for assistance.
64%
Market Research11/09/2026

Additional Details

Solicitation Number

12445526Q0113

Archive Date

Sep 12, 2026

Office Address

Atlanta, GA, 303092449