Fire Extinguisher Service
Archived on September 23, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 5:00 PM EDT
- Posted
- September 14, 2026
- Notice type
- Presolicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT STEWART
- Place of performance
- Georgia, 31409
- PSC
- J012: MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- PANMCC-26-P-0000054269
- Notice ID
- 4aca7fc9fe274b41bdedba4e2f266011
Description
This is a non-personnel services contract to provide an initial assessment visit, pickup, inspections/maintenance, and delivery of 1239 fire extinguishers of various types and sizes pickup from various building locations on Hunter AAF.
Each battalion within the brigade will schedule consolidated fire extinguisher services separately, on a quarterly basis, during this period.
Contractor visits will occur at buildings 7901, 850, 860 and 1296 on HAAF.
Services will be provided on a quarterly basis.
Extinguisher Inventory
10LB:
ABC 150
BC 28
Purple K 17
CO2 3
Halon 2
50LB:
ABC 14
5LB:
ABC 548
15LB:
ABC 51
20LB:
ABC 420
125LB:
ABC 6
5. Specific Tasks:
Tasks will be performed in accordance with NFPA 10, AR 420-5, and OSHA regulations.
5.1. The Contractor shall execute quarterly service dispatches to inspect and remediate 100% of inventory fire extinguishers, ensuring correction of all deficiencies within 5 business days.
5.2. The required fire extinguisher periodic maintenance includes annual inspections, 5/6 years maintenance (depending on the extinguisher type), and 10/12-year hydrostatic testing (depending on the extinguisher type).
5.3. Pressurized fire extinguishers require the following services (inspection, maintenance, and/or hydrostatic testing).
5.4. New extinguishers require an initial inspection to confirm the weight, pressure, condition, and provide the record on an inspection tag; all conducted by qualified personnel.
5.5. Annual inspections/maintenance includes full mechanical check, weighing, and servicing by qualified personnel.
5.6. During 5/6 year maintenance, extinguishers must be disassembled, emptied, and serviced.
5.7. Hydrostatic testing involves the same process as 5/6 year maintenance with an addition structural test to ensure cylinder integrity.
5.8. 14 Days to perform service, unless an understanding is agreed upon between the unit POC, the contracting officer, and the contractor. In the event a unit is activated for deployment, the Government will not be responsible to pay for the quarterly services not used under the contract. The contractor will be notified by the COR, in writing, explaining the length of the deployment and the period during which services will not be required for a particular unit. The contractor will cease billing during the period during which services will not be required for a particular unit.
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
4. 3CAB PWS Fire Ext Service Contract CAO 9SEP26.pdf
541 KBAdded in Presolicitation version 5Posted
Lifecycle
- 1Version 1PresolicitationArchived
Fire Extinguisher Service
- 2Version 2PresolicitationArchived
Fire Extinguisher Service
- 5Version 5PresolicitationArchivedCurrent
Fire Extinguisher Service
- 6Version 6Combined Synopsis/SolicitationArchived
Type changed from Presolicitation to Combined Synopsis/Solicitation
Fire Extinguisher Service
Similar Opportunities
Additional Details
Solicitation Number
PANMCC-26-P-0000054269
Archive Date
Sep 23, 2026
Office Address
FORT STEWART, GA, 31314-3324