GovChime
Archived

Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

Overview

Response deadline
1:00 PM EDT
Posted
June 12, 2025
Notice type
Solicitation
NAICS
236220: Commercial and Institutional Building Construction
Agency
Department of WarDepartment of the Army

Notice details

Office
W2SD ENDIST NEW ENGLAND
Place of performance
Hanover, NH, 03755
Last updated
Nov 12, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912WJ25BA018
Notice ID
01c8dade32ec4133b306850808e44937

Description

The U.S. Army Corps of Engineers (USACE), New England District is solicitating an Invitation for Bids (IFB) for Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH. This will be a 100% Small Business Set-Aside IFB procurement. The NAICS code for the work described below is 236220 and the size standard is $45 million. The estimated cost range of this project is between $500,000 to $1 Million. The project site is at the TIAC Building located on the CRREL campus. CRREL is a USACE research campus which solves important problems of the Department of Defense and the Nation by advancing and applying science and engineering to complex environments, materials and processes with unique core competencies related to the Earth?s cold regions. This project is to construct a new egress doorway for the building and will enhance the mobility and aesthetics for a world class research facility. The work consists of providing Construction Services to demolish the existing suspended concrete walkway (20 LF) and the associated metal egress doorway. A new secured, storefront style entrance will be constructed in a relocated area on the south facing side of the building. The new egress doorway will include a heated vestibule (100 SF) and additional work for interior construction such as new partitions and finishes to accommodate a configured egress path in the building. Ancillary renovation impacts include electrical work, HVAC, and life safety systems. All work is located on an access controlled military installation.The TIAC building was constructed in 1992 and is primarily an office building. It is a 4-story steel structure enclosed by a mixture of 6? CMU cavity walls with brick veneer and metal stud walls with insulated metal panel. The first-floor level has a 1-foot raised access floor throughout.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • Bid Abstract.pdf

    502 KBAdded in Solicitation version 12Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice f1be367adee54b9282a818b324af11b1 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 5302258a3c904bcaac5fe238933f0391 on SAM.gov

  3. 3
    Version 3SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 3d6d26889f994005ab9f9bd6962f1f80 on SAM.gov

  4. 4
    Version 4SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 81de768e276445cea72da2fd1b61a4ea on SAM.gov

  5. 5
    Version 5SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 52d858c389744ce18b4c6b5b84044ec5 on SAM.gov

  6. 6
    Version 6SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 1242225508cd45f2949dbb4d5036770b on SAM.gov

  7. 7
    Version 7SolicitationArchived

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 791dc54be96149aaa75241b90ce2000e on SAM.gov

  8. 12
    Version 12SolicitationArchivedCurrent

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice 01c8dade32ec4133b306850808e44937 on SAM.gov

  9. 10
    Version 10Award NoticeArchived

    Type changed from Solicitation to Award Notice

    Construction Services to relocate the egress door for the Technical Information Analysis Center (TIAC) located at the Cold Regions Research and Engineering Laboratory (CRREL) in Hanover, NH.

    Notice e71e076bfe184656a72c0ad836238b70 on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationRelated noticeApr 11, 2025

    TIAC Egress Door Relocation, Cold Regions Research Engineering Laboratory, Hanover, NH

    Notice 00005ffb0d5f4bdaac3ca6175b9d9900 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W912WJ25BA018

Archive Date

May 30, 2026

Office Address

CONCORD, MA, 01742-2751