Notice ID: 509ba052ef7e44a1b2d26b76c7b16c20Combined Synopsis/Solicitation
W045--Boiler Rental
Responses closed . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM EDT
- Posted
- October 20, 2026
- Notice type
- Combined Synopsis/Solicitation
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242)
- Place of performance
- Department of Veterans Affairs Franklin Delano Roosevelt Hospital, Montrose, New York, 10548
- PSC
- W045: LEASE OR RENTAL OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24227Q0042
- Notice ID
- 509ba052ef7e44a1b2d26b76c7b16c20
Description
36C24227Q0042 Mod 2 Answers to questions submitted: Q1: What is the observed historical peak steam load of the facility? A1: 120,000 lb./hr. Q2: Will the Montrose VAMC waive the requirements of the VHA Safety Device and Testing Manual? A2: No. Q3: Air permits for emissions are the responsibility of the entity operating/generating the emission, not the owner of the equipment. Please clarify. A3: VA only, not the vendor. Q4: Will the VA change the 9PPM NOx requirement to 30 PPM? A4: No. Q5: Please clarify the size of the Boiler. A5: 800 HP Q6: Will fuel for the rental boiler be furnished by the Government of the Contractor? A6: Government Q7: Confirm intended placement and connection routing if boiler placement is on the south end but connections are at the north end? A7: East side of the plant (end near Boiler 1 near Building 24 hazmat storage area) Q8: What is the required installation and ready for service date? A8: Installation 11/1/2026. Ready for service 12/1/2026. Q9. Is a rental unit rated at about 30ppm NOx on natural gas acceptable for the temporary heating period, given that it is a temporary rental operating under the facility s existing permit? A9. Yes Q10. If 9 ppm NOx is mandatory, will the Government accept a unit fitted with flue gas recirculation (FGR) or selective catalytic reduction (SCR) to meet it, and will any additional time be allowed for delivery? A10. The most important factor is that the vendor make the delivery date, so the 9-ppm cis is not a deal breaker. Q11. The requirement lists a 95 PSIG operating pressure but also references 35,000 lb./hr. at 212° F and a 15 PSIG code. What operating pressure should the rental boiler be size for? A11. 95 PSI is sufficient. Q12. Can a portable day tank with a capacity of 10,000 gallons be placed next to the portable boiler in lieu of installing a return line several hundred feet across to the opposite end of the boiler plant? A12. No. ** Please acknowledge all amendments with your response**
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Files (9)
- Download
36C24227Q0042 0002.docx
30 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
36C24227Q0042 0001.docx
16 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
2015-4187 05132026.pdf
92 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
temp steam.jpg
222 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
temp water.jpg
202 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
temp gas.jpg
208 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
temp oil.jpg
162 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
Temp electric.jpg
195 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
36C24227Q0042.docx
52 KBAdded in Combined Synopsis/Solicitation version 1Posted
Links (1)
- Department of Veterans Affairswww.va.govPosted
Lifecycle
- 1Version 1Combined Synopsis/Solicitation
W045--Boiler Rental Montrose VAMC
- 2Version 2Combined Synopsis/Solicitation
W045--Boiler Rental Montrose VAMC
- 3Version 3Combined Synopsis/SolicitationCurrent
W045--Boiler Rental
Similar Opportunities
- Boiler Rental - VA Hudson Valley HCS Montrose Campus
Department of Veterans Affairs · Posted 09/11/2026
- Z1DA--NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOC
Department of Veterans Affairs · Posted 11/02/2026
- H245--FY27 - VH WNY Backflow Prevention Testing Services
Department of Veterans Affairs · Posted 10/28/2026
- Z1DA--NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOC
Department of Veterans Affairs · Posted 10/14/2026
- J045--36C24226P1049 - BOILER REPAIR HUDSON VALLEY VAHCS - MONTROSE CAMPUS (1X) -
Department of Veterans Affairs · Posted 09/29/2026
Additional Details
Solicitation Number
36C24227Q0042
Archive Date
Dec 20, 2026
Office Address
ALBANY, NY, 12208