GovChime
Notice ID: 1dbab732fc1b42eaa6a5db7b2487db7aSolicitation

26 WPS - WT15754265 - Mini Split Upgrade

Responses closed . Full description on SAM.gov.

Overview

Response deadline
2:00 PM PDT
Posted
August 13, 2026
Notice type
Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of WarDepartment of the Air Force

Notice details

Office
AIR COMBAT COMMAND.FA4861 99 CONS LGC
Place of performance
B119, Nellis Air Force Base, NV, 89191
PSC
Z2JZ: REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
FA486126Q0018
Notice ID
1dbab732fc1b42eaa6a5db7b2487db7a

Description

Construct and install two maintenance pads to house all condensing units and provide single line as built drawings, install a two sided screen block at the front of the building matching the existing CMU block color and style, use solid and vented CMU blocks to ensure sufficient airflow around all condensing units, and build screen block walls two rows higher than the condensing units; the contractor shall supply a weatherproof 120V maintenance receptacle for each pad, core drill the existing wall of Building 119, install a 3 inch PVC pipe sealed with acoustical seal to maintain ICD 705 compliance per Tech Spec 1.5.1, install insulation on all line sets entering Building 119, run all electrical from Room 119s electrical mechanical room using panel EDH 1 3 rated at 480/277V and 800 amps, tie all new HVAC systems to the existing generator for backup power, surface mount electrical conduits in Room 119 and the exterior HVAC yard, run conduits underground to each maintenance pad, and supply a weatherproof disconnect for each condensing unit; the contractor shall install new cassette type HVAC systems in Rooms 112, 113, 114, and 132 using the existing suspended ceiling grid with added support, provide a 1 ton HVAC system with a separate controller for Room 112, provide 2 ton HVAC systems with separate controllers for Rooms 113 and 114, and provide a 4 ton HVAC system with a separate controller for Room 132; all design and construction shall comply with the current International Building Code, UFC standards, all applicable public laws, executive orders, CFR requirements, DOD instructions and directives, Nellis ID2 standards, and Clark County, Nevada, and federal codes and laws, and any discrepancies between codes or standards and contract documents shall be immediately reported to the Contracting Officer, with the more stringent requirement applying unless otherwise directed. 26 WPS request this HVAC installation and testing be accomplish within, 160 days, period of performance. Proposals will be evaluated using lowest price, technically acceptable. A site visit will take place on 8/4/2026 at 0830 AM PDT, meeting in front of building 119 main entrance. Please ensure your base pass request has been submitted to me by 2PM PDT on 7/24/2026 if you do not have base access to Nellis AFB to ensure you have access by the date of the site visit. Proposals are due by 8/18/2026 at 2:00 PDT. Answers will be provided via a solicitation amendment.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Lifecycle

  1. 1
    Version 1Solicitation

    26 WPS - WT15754265 - Mini Split Upgrade

    Notice d7ae5520a976485c9818d5f1f7d508bd on SAM.gov

  2. 2
    Version 2Solicitation

    26 WPS - WT15754265 - Mini Split Upgrade

    Notice 5bb29ed069034960a2a748073bf68497 on SAM.gov

  3. 3
    Version 3Solicitation

    26 WPS - WT15754265 - Mini Split Upgrade

    Notice 4b4b3aeb60f34089a846f9c2480a13d3 on SAM.gov

  4. 4
    Version 4SolicitationCurrent

    26 WPS - WT15754265 - Mini Split Upgrade

    Notice 1dbab732fc1b42eaa6a5db7b2487db7a on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

FA486126Q0018

Archive Date

Aug 13, 2027

Office Address

NELLIS AFB, NV, 89191-7063