GovChime
Notice ID: da8e3f1924574f4f9cb44186f92733e6Solicitation

HJZH 21-4004 Repair Replace Boiler B55804

Archived on September 21, 2021. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM UTC−08:00
Posted
August 18, 2021
Notice type
Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of WarDepartment of the Air Force

Notice details

Office
FA5000 673 CONS LGC
Place of performance
Jber, AK, 99506
Last updated
Dec 4, 2025

Identifiers

Solicitation number
FA500021R0064
Notice ID
da8e3f1924574f4f9cb44186f92733e6

Description

0002 The purpose of this amendment is to attach the contractors Questions and Answers. 0001 The purpose of this amendment is to replace attachment 7 with a uncorrupted version. Site visit information was added as attachment 11. Project consists of work to replace the hot water boiler and associated equipment. Demolition work includes removal of existing WEIL-McLAIN Boiler, BL-976-WS, and controls. The new work will include installation of new Hot Water Boilers and controls, and new Automated Logic Controls (ALC) DDC, installed by Meridian Systems, Inc. DDC to provide tandem boiler operation, efficiency operation with run time equalization, and modulating fire control.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:FA500021R0064
  1. Pre-Solicitation
  2. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. Pre-SolicitationJul 19, 2021

    HJZH 21-4004 Repair Replace Boiler Bldg B55804

    Notice 9cdbb4cab9ea4107983f55a96bdae7e1 on SAM.gov

  2. 3×
    SolicitationCurrentAug 6, 2021

    HJZH 21-4004 Repair Replace Boiler B55804

    Notice da8e3f1924574f4f9cb44186f92733e6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
THE TIMELINE FOR VISIT WILL BE 11/3/26-11/6/2026, 11/9/2026-11/10/2026 8AM- 3PM EST. SITE VISITS: MUST BE COORDINATED WITH DC1 MICHAEL BUSH VIA PHONE 934-235-0487. This project consists of combustion analysis, calibration, and commissioning services for eleven (11) boilers at the U.S. Coast Guard housing area at Station Eaton’s Neck.(12 Lighthouse Rd, Northport, NY 11768) Each housing unit contains the following equipment covered under this agreement: Boiler: Weil-McLain EVG 299 (280,000 BTU) Hot Water Storage Tank: Weil-McLain AQUA PLUS – 55 – S2 The purpose of this requirement is to verify and adjust boiler combustion settings in accordance with applicable manufacturer specifications; support safe, efficient, and reliable boiler operation; and document any equipment conditions requiring work beyond the scope of combustion calibration and commissioning.
65%
Combined Synopsis11/13/2026
THIS IS A SOURCES SOUGHT NOTICE. THIS NOTICE IS ISSUED FOR MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION OR INVITATION FOR OFFERORS TO SUBMIT QUALIFICATION DOCUMENTS OR PROPOSALS. SHOULD THIS REQUIREMENT MOVE FORWARD, A SYNOPSIS OF THE PROPOSED CONTRACT ACTION WILL BE POSTED AT A LATER DATE PROVIDING INSTRUCTIONS FOR OFFERORS TO RESPOND TO THIS OPPORTUNITY. Please only respond to this sources sought notice if you are seriously interested and if your company is capable of performing the corresponding work required. The Federal Bureau of Prisons (FBOP), Federal Detention Center (FDC) Philadelphia, Pennsylvania, anticipates the issuance of a solicitation for the award of a firm-fixed-price construction contract for a project titled Replace Boilers for FDC Philadelphia located at 700 Arch Street, Philadelphia, Pennsylvania, 19106. The awarded contractor will provide all necessary labor, materials, equipment, tools, and incidentals required to remove and dispose of three (3) existing Unilux hot water heating boilers and to furnish and install three (3) new Unilux ZF-1000W-FE boilers (brand name or equal) with dual-fuel burners and controls. Work includes connection to existing piping, breeching, electrical service, and the Building Automation System, as well as hydrostatic testing, start-up, and commissioning. One (1) boiler must remain operational at all times during construction. Refer to the attached Statement of Work and drawings for complete details. The solicitation will be posted at a later date. Access to the solicitation will require an active vendor registration at SAM.gov. You will need to request access to the controlled document(s) and receive approval prior to being able to view the files. If you encounter problems requesting access to these documents, please refer to the Help section on SAM.gov or contact the Federal Service Desk at 866-606-8220. The North American Industrial Classification System (NAICS) code applicable to this requirement is 238220 - Plumbing, Heating, and Air-Conditioning Contractors with a corresponding small business size standard of $19.0 million average annual receipts for the firm's preceding three fiscal years. The estimated magnitude of this project lies between $1,000,000 and $5,000,000. Interested bidders must be registered in the System for Award Management (SAM) at https://urldefense.us/v3/__https://sam.gov__;!!KDHJTnLT9htas3gmAhw!eCpfFV-1erMjrD_6TvycEXS7FramRYQ1fgdAWzohAQiBPS2AV-NYpiHnWdBMmT71Ua0fcOVNiGdPNo3tet8LEuxWAA$ . The FBOP is seeking small business contractors for this project. Only small business concerns should respond to this notice; responses from large businesses will not be considered for this market research. Your business size metrics information entered in your SAM registration must be less than or equal to the small business size standard specified above to qualify as a small business. You should be certified in accordance with SBA requirements if you are claiming a socioeconomic status (WO, 8(a), HUBZone, SDVOB). We verify this information utilizing the SBA website "Small Business Search". Please verify your status before submission. Interested small business contractors are requested to respond to this notice by adding their names to the Interested Vendors List for this posting on the SAM website at https://urldefense.us/v3/__https://sam.gov__;!!KDHJTnLT9htas3gmAhw!eCpfFV-1erMjrD_6TvycEXS7FramRYQ1fgdAWzohAQiBPS2AV-NYpiHnWdBMmT71Ua0fcOVNiGdPNo3tet8LEuxWAA$ . You must be logged in to your vendor account in order to access the Interested Vendors List. Please add your business name only if you are interested in submitting a bid as a Prime contractor and are capable and eligible to compete for and perform this project. This notice is intended only for those who would be entering into a Prime contract with FBOP for the entirety of the project. The FBOP does not award subcontracts. Subcontracts (if applicable/necessary) are the responsibility of the Prime contractor. The FBOP has no privity of contract with subcontractors. Interested parties are also requested to complete the attached Market Research Questionnaire and return the completed document to j2xcortez@bop.gov. The synopsis of proposed contract action will include further instructions for responding to this opportunity. Interested bidders are advised to continuously monitor https://urldefense.us/v3/__http://www.sam.gov__;!!KDHJTnLT9htas3gmAhw!eCpfFV-1erMjrD_6TvycEXS7FramRYQ1fgdAWzohAQiBPS2AV-NYpiHnWdBMmT71Ua0fcOVNiGdPNo3tet_U62a4uA$ for all future updates.
56%
Market Research11/19/2026
Upgrade the existing heating infrastructure in building 1515 on Hill AFB in accordance with the Statment of Work. The objective is to transition from the current steam heat exchanger system to a more efficient, decentralized gas-fired hot water boiler system.
54%
Combined Synopsis11/12/2026
*****Amend 0003 - The purpose of Amend 0003 is to revise the requirement removing temporary cooling and to extend the quote due date to 7 July 2026 at 10:00 AM EDT.***** *****Amend 0002 - The purpose of Amend 0002 is to include Attach 8 - RFIs with Answers and Attach 9 - Attachment to RFI Answers. The quote due date is extended to 24 June 2026 at 10:00 am EDT. ***** *****Amend 0001 - The purpose of Amend 0001 is to incorporate photos from the Site Visit as Attach 7 - Site Visit Photos. ***** The 911th Airlift Wing, Air Reserve Station (ARS) has a project to replace the chiller in Building 418 in Coraopolis, PA. Solicitation FA671226Q0010 is issued as a Request for Quote (RFQ). ***This is the re-release of FA671226Q0003.*** The solicitation document, with the incorporated clauses and provisions, will be issued in accordance with the Federal Acquisition Regulation (FAR) Parts 12 and 36 and will be incorporated in the awarded firm-fixed price contract. Interested vendors should reference the solicitation documents for all terms and conditions. All interested and eligible parties are responsible for monitoring this website to ensure they have the most current information (i.e. Amendments) for the solicitation. No paper solicitation will be available. Procurement is solicitation as a one hundred percent (100%) Small Business set-aside. The solicitation will result in a Firm-Fixed Price (FFP) contract. The North American Industry Classification System (NAICS) code is 238220 with a small business size standard of $19 Million. The magnitude of construction for this procurement is estimated to be between $250,000 and $500,000. Site Visit: An organized site visit will be held at the project location. See solicitation for details. In order to attend the site visit, you are required to pre-register. Attendance at the site visit will be limited to no more than two (2) representatives per company. The site visit will be held for the purpose of providing contractors with the opportunity to familiarize themselves with the site which may be helpful in the preparation of offers. Attendance at the site visit is not mandatory for offer submission; however, failure to visit the site will not relieve or mitigate the successful contractors responsibility and obligation to fully comply with the terms, conditions, and specifications contained and/or referenced in this document. Telephone requests for information will not be accepted or returned. In order to submit an offer on this project, your company must be registered in the System for Award Management (SAM) and maintain an active registration. Please see the attached solicitation and supporting documents.
54%
Combined Synopsis07/07/2026
This is a construction requirement for the design, demolition and installation of HVAC equipment in building 611 in accordance with the Statement of Work. The existing chiller and chilled water pump shall remain and be used in the design. Period of Performance: Not to exceed 167 calendar days after Notice To Proceed issuance. Competition: This requirement is a 100% Small Business Concern Set Aside for North American Industry Classification System (NAISC) code 238220.The Magnitude of this requirement in accordance with Federal Acquisition Regulation (FAR) 36.204(d) is valued between $250,000.00 and $500,000.00. ***A site visit is scheduled for Tuesday, 3 February 2026 / 10:00 (local) Eastern Standard Time EST. Site visit location is 330 Killian Avenue, Building 611, Shaw AFB, SC 29152. SITE VISIT ATTENDANCE FOR PRIME CONTRACTORS COMPETING FOR AWARD IS MANDATORY! Please refer to attachments 14 through 16 to ensure to adhere to all requirements necessary to obtain a pass to access the installation. Please send base access request to Ms. Goodman and Mr. Ford at kishauna.goodman@us.af.mil and darrel.ford.3@us.af.mil no later than Wednesday, 28 January to allow time for processing. Escorts will NOT be provided. All questions for this solicitation will be due no later than Wednesday, 11 February 2026 / 1:00 P.M. (local) EST. Submit questions to the Contracting Officer, Mr. Darrel Ford at darrel.ford.3@us.af.mil and the Contract Specialist, Ms. Kishauna Goodman at kishauna.goodman@us.af.mil. Bids for this solicitation are due no later than Thursday, 16 April 2026 / 1:00 P.M. (local) EST. Only electronic bids will be accepted through the Procurement Integrated Enterprise Environment (PIEE) system for this solicitation posted on SAM.gov. Bids may be accepted at email addresses darrel.ford.3@us.af.mil or kishauna.goodman@us.af.mil ONLY after attempts to post bid through SAM.gov / PIEE systems are unsuccessful and prior coordination with Mr. Ford or Ms. Goodman. Bid Opening is scheduled for Friday, 17 April 2026 / 10:00 (local) EST. Bid opening location is 20th Contracting Squadron, 321 Cullen Street, Building 216, 2nd Floor Conference Room 219. If attending in person, please ensure installation access requirements are met. Escorts will NOT be provided. Bid opening procedures will also be available on Microsoft Teams. A dial-in number will be made available prior to bid opening. ***SOLICITATION AMENDMENT FA480326B0010001*** The purpose of this amendment is to provide updates to solicitation FA480326B0001. Updates include replacing Statement of Work dated 11 Sep 25 with Statement of Work dated 3 Mar 26. removing Design Phase requirement, reducing Period of Performance Dates from 167 calendar days to 90 calendar days, incorporating questions & answers into the solicitation and adding site visit sign-in sheet. Please see attachment Solicitation Amendment FA480326B00010001, Attachment 01, Revised SOW dated 3 March 2026, Attachment 17, B611 HVAC Repair Sign-In Sheet and Attachment 18, B611 HVAC Repair Questions-Answer attachments for details. **Notice to Offerors: Ensure to acknowledge this Amendment per Block 19, ACKNOWLEDGMENT OF AMENDMENTS on Standard Form 1442. Failure to do so may result in offeror's bid ineligible for consideration***
51%
Solicitation04/16/2026

Additional Details

Solicitation Number

FA500021R0064

Archive Date

Sep 21, 2021

Office Address

JBER, AK, 99506-2501