GovChime
Notice ID: d424c42a048a49a78c61dce115a4670cSolicitation

INTRAVENOUS SYRINGE PUMP (IVSP)

Archived on June 13, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM UTC−04:00
Posted
June 13, 2024
Notice type
Solicitation
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of WarDEFENSE HEALTH AGENCY (DHA)

Notice details

Office
ARMY MED RES ACQ ACTIVITY
Last updated
Sep 25, 2026

Identifiers

Solicitation number
HT942524R0076
Notice ID
d424c42a048a49a78c61dce115a4670c

Description

USAMMDA has a requirement to procure an Intravenous Syringe Pump (IVSP). The IVSP is a medical device used to administer a highly accurate and consistent volume for small amounts of intravenous (IV) fluids such as antibiotics, regional anesthetics, antiarrhythmic medications, and chemotherapeutic agents in hospitals (role of care 3), veterinary medicine, and medical units able to conduct advanced resuscitation procedures and lifesaving surgeries (role of care 2). IVSPs should be able to provide a flow of 0.1 to at least 99.9 mL/hr in 0.1 mL increments and maintain an accurate flow rate to within 5% of flow settings. Pumps should accommodate syringe sizes from 3 to 60 mL. Pumps that accept syringes smaller than 3 mL may be advantageous in some settings. The pump should be designed to revert to a KVO (keep vein open) rate between 1 and 5 mL/hr (but not greater than the programmed flow rate) once the programmed volume is delivered. Facilities should also look for pumps that have pump-based priming.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

No documents available.

Lifecycle

Solicitation:HT942524R0076
  1. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. 3×
    SolicitationCurrentMay 29, 2024

    INTRAVENOUS SYRINGE PUMP (IVSP)

    Notice d424c42a048a49a78c61dce115a4670c on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
52%
AwardedOpen
JUSTIFICATION POSTING
49%
Sole Source / J&AOpen
Revision: 01 Effective Date: 11/15/2024 Acquisition ID#36C252-27-AP-0957 Page 1 of 2 Please note that this is not a request for proposal nor a request for quote as there is no solicitation document available. Therefore, this is a notice of intent issued by the Department of Veterans Affairs to negotiate a limited source contract with Iramed Corporation. DEPARTMENT OF VETERANS AFFAIRS Justification for Single Source Awards RFO FAR 12.102 For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K) Acquisition Plan Action ID: 36C252-27-AP-0957 Contracting Activity US Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) VISN 12 115 S. 84th Street Milwaukee, WI 53214 2237: 556-27-1-2993-0011 Brief Description of Supplies/ Services required and the intended use/Estimated Amount: The Captain James A. Lovell Federal Healthcare Center (FHCC), Building 556, Nursing Services, is requesting the acquisition of one MRI-compatible IV infusion pump system for the Intensive Care Unit (ICU). MRI-compatible infusion pumps are medically necessary for ICU patients who require continuous vasoactive or sedative titratable infusions while undergoing magnetic resonance imaging (MRI) to support the diagnosis and evaluation of complex disease processes. Estimated Amount: $105,270.20 Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The availability of this equipment will enable FHCC to perform medically necessary MRI examinations on-site, reducing the need to transfer patients to outside facilities. Currently, these patients are often taken for CT scans; however, CT imaging may not provide the comprehensive diagnostic information required for certain conditions Standardization and compatibility with the MRI IV infusion equipment currently installed at the facility are essential requirements for this acquisition. The requested system is intended to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could result in incompatibility, require additional accessories or system modifications, necessitate staff retraining, and increase costs to the facility. Therefore, procurement of the compatible MRI IV Infusion Pump System is justified to maintain system continuity, operational efficiency, and patient-care capabilities. Description of market research conducted and results or statement why it was not conducted: Market Research Findings: An SBA.gov search under NAICS code 339112 identified zero (5) SDVOSBs and (13) VOSBs. Two additional searches were conducted on sba.gov by combining NAICS code 339112 with the keywords Quad Non-Magnetic IV Pump System and Non-Magnetic IV Pump System and applying specific filters for SDVOSBs and VOSBs. Both searches yielded zero (0) results. A search on GSA Advantage using the keywords Non-Magnetic IV Pump System produced several results that does not appear to meet the requirement. The Contracting Officer (CO) searched Google.com using the keywords Non-Magnetic IV Pump System and identified several vendors, including BD, BioSpace, Hospital & Healthcare management, Iradimed, InMed, MDPI, and Ivenix. Although several alternative vendors were identified, their products are not compatible with the MRI IV infusion equipment currently installed at the facility. Standardization and compatibility are essential requirements for this acquisition. The requested system is designed to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could lead to compatibility issues, require additional accessories or system modifications, necessitate staff retraining, and increase facility costs. Therefore, procuring the compatible MRI IV infusion pump system is justified to ensure system continuity, operational efficiency, and uninterrupted patient-care capabilities. CO received a letter of authorization from the vendor that certifies Iradimed Corporation is the sole manufacturer and authorized seller of the MRidium 3870 MRI Infusion System and its accessories. Due to proprietary considerations, Iradimed Corporation is also the exclusive source for replacement parts for the MRidium MRI Infusion Pump System. The MRidium 3870 MRI Infusion System is the only nonmagnetic, MRI-compatible IV infusion pump currently available on the market. Contracting Officer's Certification: Purchase is approved in accordance with RFO FAR 12.102. I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief. Vernise L. Newton Contracting Officer
48%
Special Notice11/17/2026
SUBJECT: Brand-Name Solicitation; Nordson Medical Quest MPS 3 Console and Controller, Walter Reed National Military Medical Center 1.) This is a Brand-Name Only requirement for commercial products or commercial services prepared in accordance with the format in RFO Part 12, as supplemented with additional information included in this notice. This announcement constitutes the solicitation; Quotes are being requested in response to this announcement 2.) The Solicitation ID for this requirement is HT001427QE013, This Requirement is being solicited as a Request for Quotes (RFQ). 3.) This solicitation document incorporates provisions and clauses from Federal Acquisition Regulation (FAR), FAC 2026-01; and supplemental Regulations from the Defense Federal Acquisition Regulation Supplement (DFARS), DFARS Change 5/07/2026. 4.) This requirement is being solicited under other than full and open competition as a brand-name requirement under the NAICS code 339112. 5.) Offers are due 20 November 2026, by 1000 EST. 6.) The Primary POC for this requirement is Contract Specialist, Matthew Shozo Tsueda; Phone 907-201-0308; Email: Matthew.S.Tsueda.Ctr@Health.Mil
44%
Solicitation11/20/2026
44%
Market Research11/18/2026

Additional Details

Solicitation Number

HT942524R0076

Archive Date

Jun 13, 2025

Office Address

FORT DETRICK, MD, 21702