Notice ID: 464cde224c82c51ef0e4210c1e397d09Presolicitation
C--A/E Services for Seismic Corrections Buildings 128/133 VA Long Beach Healthcare System, Long Beach, CA
Archived on March 15, 2009. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 AM UTC−05:00
- Posted
- December 15, 2008
- Notice type
- Presolicitation
- NAICS
- 541310: Architectural Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)
- Place of performance
- VA Long Beach Healthcare System;Long Beach Medical Center;5901 East 7th Street;Long Beach, CA 90822 US
- PSC
- C: ARCHITECT/ENGINEER SERVICES
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- VA-101-09-RP-0026
- Notice ID
- 464cde224c82c51ef0e4210c1e397d09
Description
The Department of Veterans Affairs, Office of Construction and Facilities Management, Washington, DC is seeking architect or architect/engineer (North American Industry Classification Code (NAICS) 541310) firms capable of preparing all design documentation including, but not limited to, advance/master planning and design a new Mental Health Facility; a new Community Living Center (CLC), formerly called Nursing Home; improvements to the energy/chiller plant; and, demolition of two (2) buildings, in the Long Beach, California area. Prime contractor should have, at least, the following licensed/registered specialty disciplines be members of the firm, or team, with demonstrable expertise in their respective fields: Architects; Medical Planners; Structural, Seismic, Mechanical, Geo-technical, Communication, and Electrical Engineers; Interior Designers; an independent Commissioning Agent; and Cost Estimators with experience in the planning and design of new hospitals, large medical and significant outpatient/ambulatory care clinics, long term care facilities, mental heath facilities or similar complex healthcare projects. VA proposes to construct the following at the VA Long Beach Healthcare System: (1) a new Mental Health facility of approximately 115,000 GSF; (2) a new Community Living Center (CLC), formerly called Nursing Home, of approximately 160,000 GSF; (3) improvements to the energy/chiller plant; and, (4) demolition of Buildings 128 and 133. Once a thorough analysis of the users and the facilitys needs has been completed, the scope and method of meeting those needs may change and require a different approach. Seismic design will adhere to VAs manual for Seismic Design Requirements (H-18-8). Space layout and interior partitioning will meet current VA Space Planning Guidelines and optimize patient care and staff efficiency. Applicants must demonstrate success in sustainable design including prescribing the use of recovered materials, achieving waste reduction, along with water and energy efficiencies in design; and, in addition, the project will comply with the VA Sustainable Design and Energy Reduction Manual. Mechanical, plumbing, electrical, nurse call, medical gases, and fire and safety systems will meet current codes and standards. All structures and utilities will be designed to meet VAs criteria as detailed in its Physical Security Design Manual for VA Facilities, both Life-Safety Protected and Mission Critical Facilities. The space will be in compliance with the Uniform Federal Accessibility Standards (UFAS) and PG-18-13 in all areas. Required services will include preparation of schematics and design development plans, including all appropriate architectural and engineering disciplines, and a firm estimate of construction cost. The contract will include a government option for: design-build RFP package or construction document preparation; construction period services, and site visits. The completed project should be capable of achieving LEEDS Silver equivalency. Only firms, or teams, with in-house architectural services, recent experience in the design of contemporary, state-of-the-art medical facilities similar to that proposed. Additional tasks may include site analysis and selection of potential new locations for the new facilities. Emphasis will be placed on cost and scope management capabilities and previous successful experience with construction and renovations of medical facilities, along with the firms, or teams, Quality Assurance /Quality Control procedures. In addition, the firms or teams must demonstrate their ability to effectively utilize IFC version 2x-3 (or later) compliant parametric Building Information Modeling (BIM) system in developing this project from its initial conception through completion of documentation. The team shall have the experience, ability, and data management skills to execute an integrated design approach using BIM technology. Only architects or architect/engineer firms, or teams, demonstrating the above capabilities and a planned approach to perform contract services will be considered. In addition to design capabilities, estimating capabilities of the applicants will be considered. An estimate of construction cost based on level of design detail will be required at each design phase. The selected team shall design to the governments estimated cost for construction. Applicants must have an established working office within roughly 100 mile radius of Long Beach area of California, be of sufficient size and experience to accomplish the work, and be licensed in the State of California. No firm will be considered unless an application consisting of a completed SF 330 Part I and other evidence of experience and capabilities the applicant considers relevant is received by the Office of Construction and Facilities Management, VA Cost Estimating and A/E Evaluation Service (00CFM1B) Attention: Robert T. Smoot, 810 Vermont Avenue, NW, Washington, DC 20420, five (5) copies are required within 30 days of the date of this advertisement. A current SF 330 Part II, representing and differentiating among the personnel, experience and capabilities of all involved offices, must be included with the application together with current SF 330 Part IIs for each proposed consultants office involved. Applicants will be rated based on the relevant experience - advance planning and design on projects of similar scale and scope - of both the firm(s) and assigned individuals, the applicants capacity to do the work, record of past performance on VA work, geographic consideration, the participation of minority-owned and women-owned consultants, and demonstrate success in prescribing the use of recovered materials, achieving waste reduction, energy efficiency, and systems integration in facility design. Award of contract is dependent upon the availability of funds. This is not a request for a proposal. If subcontracting opportunities exist and the submitting firm is not a small business, the small business subcontracting goals will be: (a) 28.7% for Small Business (SB); (b) 5% for Small Disadvantaged Business (SDB); (c) 5% Women-Owned Small Business (WOSB); (d) 3% for Historically Underutilized Business Zone Small Business (HUB Zone); (e) 10% for Veteran-Owned Small Business (VOSB); and (f) 7% for Service-Disabled Veteran-Owned Small Business (SDVOSB). Note: The covenant against contingent fee clause is applicable to this solicitation. *** Point of Contacts (POC): Selection Process is Robert T. Smoot, 202-461-8220; POC Scope is Larry Villaluna, 707-562-8340
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Frank A ClemonsContracting Officer 202-461-8486 Contracting Officer
Documents
No documents available.
Lifecycle
Solicitation:
VA-101-09-RP-0026- Market Research
- Pre-Solicitation
Formal solicitation typically follows within 30–60 days. (estimate)
- Market ResearchNov 11, 2008
C--A/E Services for Seismic Corrections, Building 128 and Building 133, VA Long Beach Healthcare System
- Pre-SolicitationCurrentDec 15, 2008
C--A/E Services for Seismic Corrections Buildings 128/133 VA Long Beach Healthcare System, Long Beach, CA
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
This procurement is restricted to Service Disabled Veteran Owned Small Business (SDVOSB) firms located within a 300 mile radius of the Battle Creek VA Medical Center, 5500 Armstrong Rd, Battle Creek, MI 49037. The mile restriction is in compliance with VAAR 805.207 (b). This requirement is being procured in accordance with the VAAR 836.606-73 as implemented in FAR Subpart 36.6. Description of work to be performed includes: Architect-Engineering services are required for Schematics, Design Development, Construction Documents, Technical Specifications, Construction Period Services, Site Visits, Cost Estimates, and all other related information for Project #515-14-123, Replace Fire Alarm System. The project will include design work for the preparation of 100% complete working drawings and contract documents using edited VA Master Specifications to complete the following: I. STATEMENT OF AE TASKS A. The AE shall furnish all services for a complete schematic design, design development, construction documents, bid documents, site visits, cost estimates, as-built documentation, and construction period services and all other related information for project 515-14-123 Replace Fire Alarm System for 30 buildings at the Battle Creek VA Medical Center in Battle Creek, MI. 1) Necessary site survey work such as verifying existing conditions, verifying record drawings, and verifying and analyzing utility systems shall be accomplished in conjunction with preparation of Schematic Design, and Design Development. 2) The A/E shall design a station wide fire monitoring system to be installed parallel to the existing system. Redundant monitoring: primary at building 25 and redundant at police department building 2. The system shall be designed to be monitored by wireless network including transmitters, receivers, and transceivers, including all permits, and FCC application for equipment frequency allocation. 3) The A/E shall evaluate each building to determine which field devices need to be added in accordance with current codes. 4) The AE will be required to attend in person (or Senior Delegate of AE) to pre-bid meetings, a pre-construction meeting, project construction meetings and a final inspection meeting. There will also be various construction site meetings that will require a representative of the AE. 5) AE will provide meeting notes / minutes for meetings and conference calls. 6) The A-E shall provide competent design and construction period services utilizing individuals who are adequately knowledgeable of the various design disciplines including but not limited to architectural and engineering of structural, mechanical, electrical, and special systems as required by the project. Changes in personnel from those who are proposed in negotiations, interviews, kick-off meeting, and/or A-E submission forms must be approved in writing. The registered individuals who will stamp the completed documents shall accomplish engineering design work. B. The AE shall provide cost estimation, project scheduling & phasing, bid period and construction period services as further described in the contract. Estimates shall have a full itemized line item breakout commensurate with the degree of design accomplished. At the Schematic Design phase, square foot estimates would be adequate. As the design progresses in detail, so the estimate would progress in detail. C. The AE shall provide bid documents in both hard paper copies and electronic format. Electronic format shall include AutoCAD and Microsoft Word/Excel as well as PDF format for all. Final PDF of the construction drawings shall include the professional stamp. D. AE shall design construction to phase and coordinate work to minimize disruptions to medical center operations. Outages shall be minimized and temporary conditions planned to maintain critical utility systems. Suitable space/access for mechanical room equipment maintenance must be maintained throughout construction. To keep the number of outages to a minimum, group common work. Phasing of interruptions shall be clearly indicated on the construction documents. E. A-E shall design within funding limitations. AE shall coordinate cost control measures with COR to design within funding limits. Cost control alternatives shall be explored in Design Development (DD's). The AE is required by national VA directive to include a 20% bid deduction. F. Review AE Quality Alerts from the TIL. Design completion timeframe of 190 days after receipt of the Notice to proceed. The A/E firm shall also be required to perform construction period services after award of the construction project contract. In accordance with FAR 36.204, the estimated magnitude of the resulting construction project is between $1,000,000 and $5,000,000. Qualifications (SF330) submitted by each firm for Project #515-14-123 for "Replace Fire Alarm System" will be reviewed and evaluated based on the following criteria: Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required and SF 330 submissions including any additional pages are not to exceed fifty (50) pages. Selection criteria shall be in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1 and VA Acquisition Regulation (VAAR) Part 836.602-1 as follows: (1) Professional Qualifications: the qualifications of the individuals which will be used for these services will be examined for experience and education and their record of working together as a team. The specific disciplines which will be evaluated are architectural, engineering, and estimating. (2) Specialized Experience and Technical Competence: specific experience and technical skill in the type and scope of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. (3) Capacity to Accomplish the Work: the general work load and staffing capacity of the design office which will be responsible for the majority of the design and the ability to accomplish the work in the required time will be evaluated. (4) Past Performance: the past performance of the firm on contracts relevant in scope to the advertised project that were accomplished with the Department of Veterans Affairs, other Government agencies, and private industry in terms of cost control, quality of work, and compliance with performance schedules will be examined. Project past performance references older than 3 years will receive a lesser score than those references for projects accomplished within the past 3 years. (5) Location of Design Firm: the geographic proximity of each firm to the location of the VA Medical Center will be evaluated. This criterion will apply to the office from which the majority of the design services will be performed. Scoring will be based off of the proposed location of the prime contractor firm for this category. Scoring shall be as follows: within 75 miles - Excellent (Blue); 76-125 miles - Very Good (Green); 126-175 miles - Acceptable (Yellow); 176 - 225 miles - Marginal (Orange); 226 - 300 miles - Poor (Red). (6) Claims and Terminations: record of significant claims against the firm or terminated contracts because of improper or incomplete architectural and engineering services will be examined. (7) Reputation in A-E Community: reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. (8) Specific experience and qualifications: of personnel proposed for assignment to the project and their record of working together as a team. FAILURE TO CLEARLY ADRESS ALL EIGHT LISTED EVALUATION CRITERIA AND INFORMATION REQUIRED BY THE SUBMISSION REQUIREMENTS BELOW MAY RESULT IN REJECTION OF SF330. The NAICS Codes for this procurement is 541310 Architectural Services and small business size standard of $7.5 Million. Award of a Firm Fixed Price contract is anticipated. Anticipated time for completion of design is approximately 190 calendar days including time for VA reviews. The A/E firm shall also be required to perform construction period services if award of a construction project contract is made. DATABASE REGISTRATION INFORMATION: VERIFICATION OF STATUS OF APPARENTLY SUCCESSFUL OFFEROR THIS ACQUISITION IS 100% SET-ASIDE FOR QUALIFIED SERVICE DISABLED VETERAN OWNED SMALL BUSINESS AE FIRMS IN COMPLIANCE WITH VAAR 852.219.10. ONLY BUSINESSES VERIFIED AND LISTED IN THE VENDOR INFROMATION PAGES DATABASE (http://www.vetbiz.gov) SHALL BE CONSIDERED. SYSTEM FOR AWARD MANAGEMENT (SAM): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM) database at www.sam.gov and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in SAM prior to submitting their qualifications package. THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and 1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at www.sam.gov for each person providing services under this contract. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities. E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all of their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54) Qualified A-E firms are required to respond if interested by submitting one (1) original completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486) Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions must be bound in some manner (spiral, wire, binder, etc.) and a CD copy of the Standard Form 330. Completed SF330s can be delivered to Battle Creek VA Medical Center, Attn: Craig Jenkins, Contract Specialist, NCO 10 West Contracting Office (90VC), Building 9, 5500 Armstrong Rd, Battle Creek, MI 49037, no later than 3:00 p.m. EDT, April 11, 2016. Outermost envelope or packaging shall clearly identify Solicitation number and project. Information shall be submitted via commercial express service. No hand carried deliveries. Telegraphic, email, and facsimile forms are prohibited. All submissions must be bound in some manner (spiral, wire, binder, etc.). Award of any resultant contract is contingent upon the availability of funds. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted via email only (craig.jenkins@va.gov) telephone inquiries will not be honored. After the evaluation of SF330 submissions in accordance with the evaluation criteria, three or more of the most highly qualified firms will be chosen for interviews to present their approach to the design to arrive at selection of the number one firm for negotiations. The contract is anticipated to be awarded in JUNE/JULY 2016. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. | - | Pre-Solicitation | 04/11/2006 |
The agency notice ID should be 1620000393 Admendment 0002 SVO237-26 posted 09/21/2026 Add additional information in the description for clarification and correct the document number from SVO237-26 to SV0237-26. As provided, all other terms and conditions remain unchanged. Offerors must submit SF 330 Parts I and II and sign and return all admendments. The following Qualifications-Based Selection (QBS) shall be submitted by each offeror illustrating work performed within a correctional environment, addressing each criteria listed below: Professional Qualifications: Licenses, registrations, education, and overall staff capability. Specialized Experience: Past success and technical competence on similar project types. Capacity: Ability to perform the work and meet project schedules. Past Performance: Record of previous work quality, responsiveness, and client satisfaction. Technical Approach: Project understanding, quality control procedures, and innovative concepts. Geographic Location / Local Knowledge: Familiarity with the project locale, though strict local preferences are heavily restricted or capped Once the QBS has been met consideration for a contract award will be based solely upon the hourly rates, overhead and profit that are proposed and found to be fair and reasonable. | - | Solicitation | 11/02/2026 |
This is a Sources Sought Notice only. This notice does not constitute a Request for Qualifications (RFQ), Request for Proposals (RFP), or Invitation for Bids (IFB), nor does it represent a commitment by the Government to issue a solicitation or award a contract. This Sources Sought Synopsis is issued solely for market research and planning purposes to determine the availability and adequacy of potential sources. It is not a Request for Proposals or Quotes and imposes no obligation on the Government to acquire any goods or services. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The Government reserves the right to determine the appropriate acquisition approach based on the results of this market research. Responders should not anticipate feedback regarding their submissions. The Government will not pay for any costs incurred in responding to this Synopsis; all costs associated with responding are solely at the responding party's expense. The information provided herein is subject to change and is non-binding on the Government. The purpose of this notice is to conduct market research to identify potential and qualified sources, assess industry capabilities, and establish effective acquisition strategies, including potential small business set-aside opportunities. No reimbursement will be provided for any costs associated with submitting information in response to this announcement or any follow-up information requests. Overview The General Services Administration (GSA), Public Buildings Service (PBS), is conducting market research to establish Multiple-Award Indefinite-Delivery, Indefinite-Quantity (IDIQ) contracts for comprehensive, multidisciplinary Architect-Engineer (A/E) services. These contracts are intended to provide integrated, sustainable, and adaptive design solutions across federally owned and leased real property nationwide. The Government anticipates awarding multiple contracts with multi-year ordering periods (5 year base with one 5 year option) to support GSA zones and client agencies across the United States and its territories. Expected typical project size is to be above the simplified acquisition threshold of $350,000. The potential place of performance for services rendered under this contract is on an as-needed basis for federal projects anywhere in the United States and its territories. This will require the capability to travel to GSA and other Government agency office locations nationwide. In some instances, performance of services is expected to require the capability for contractors to dispatch personnel to multiple locations simultaneously. The applicable North American Industry Classification System (NAICS) code for this requirement is 541310 (Architectural Services) & 541330 (Engineering Services), which has a small business size standard of $12.5 million and $25.5 million respectively. Scope of Services Services provided under the resulting IDIQ contracts will encompass a comprehensive range of professional A/E design and engineering disciplines. Scopes of work for individual task orders may include, but are not limited to, the following: 1. Core Project Life Cycle Services - These services cover the entire project lifecycle, from initial concept to post-construction closeout. Planning and Pre-Design Feasibility, pre-design, and project development studies Master planning Cost Estimating Real Estate Market Analysis Assessment and Investigation Existing conditions surveys, and field investigation Building condition survey evaluation reports (exterior and interior) Environmental investigation, reviews, inventories, and audits Energy audits and studies Design and Documentation Concept design, Design development, and Construction document development (both architectural and engineering) Interior design, including Furniture, Fixtures, and Equipment (FFE) Building standard documents Construction Support and Closeout Constructability review and evaluation Submittal and shop drawing review Management and inspection (M&I) services during construction and Construction inspection Building and system commissioning Post Construction Contract Services (PCCS); Record and close-out documents 2. Specialized Technical & System Design - Work requested often involves the assessment, repair, and upgrade of existing complex building systems. Mechanical, Electrical, and Plumbing (MEP) Full MEP services, including design of HVAC systems and electrical systems and lighting Assessment and design for mechanical components (e.g., pumps, fans, air handlers, water distribution systems) and air distribution Design of water and waste water systems, including performance of sanitary inspections Temperature control assessment and design and BAS system assessment and integration Building Structure and Envelope Structural evaluation and design Façade evaluation and remediation design Water infiltration investigation and mitigation design Safety, Security, and Compliance Fire and Life Safety evaluation and design Rehabs to improve energy efficiency and safety concerns Seismic & Blast protection and Vertical Transportation Code Compliance 3. Required AE Disciplines and Expertise - AE firms will need staff with licensed and/or specialized expertise in the following disciplines: Core Architectural and Engineering Disciplines Architecture and Interior Architecture Mechanical Engineering, Electrical Engineering, Structural & Civil Engineering, and Plumbing Historic Preservation Specialized Expertise A Qualified/Licensed Fire Protection Engineer (NCEES)* Security Space Planning & Workplace Cost Estimating and Scheduling Environmental Services Modernization and Quality Control Building Information Modeling (BIM) Quality control review and Report writing Submission Requirements Interested firms are invited to submit a written Capability Statement. Submissions must not exceed five (5) pages in length and must address the following elements: A. Company Profile Official company name, street address, telephone number, and primary website URL. Unique Entity Identifier (UEI) and Commercial and Government Entity (CAGE) Code. Office location(s) and primary design production facilities. Business size status under NAICS 541310 or 541330 (Large Business or Small Business). Applicable SBA socio-economic certifications (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business [SDVOSB], Woman-Owned Small Business [WOSB], or Economically Disadvantaged WOSB [EDWOSB]). B. Relevant Experience Summarize three to five (3–5) relevant projects completed within the past ten (10) years. Demonstrate experience in projects of similar scale, scope, and complexity, such as federal workplace design, major repairs and alterations, or complex building systems. Include project title, customer/agency point of contact, contract value, role (Prime or Subcontractor), and a brief narrative of the work performed. C. Nationwide Capacity Demonstrate organizational capacity to manage and execute multiple task orders simultaneously across diverse geographic locations nationwide. Describe key disciplines maintained in-house versus those typically fulfilled through subcontractor or joint venture arrangements. Submission Instructions Responses must be submitted electronically via email to the primary procurement contacts listed below: Submission Deadline: Primary Contact: Point of Contact Email: Subject Line Format: Sources Sought Response - National A/E IDIQ - [Firm Name] Hard copies, telephonic inquiries, and late submissions will not be reviewed or acknowledged. All information provided in response to this notice will be used strictly for market research and acquisition planning purposes. This notice encourages participation from qualified small business concerns, including socio-economic program participants, to assist GSA in evaluating the feasibility of small business set-asides for this procurement. All prospective offerors are responsible for monitoring SAM.gov for updates, future notices, or potential solicitations related to this requirement. | - | Market Research | 11/13/2026 |
*10/21/2026- Amendment posted of Questions and responses posed by contractors. Submission due date reemains the same. THIS IS A SYNOPSIS OF PROPOSED CONTRACT ACTION. FOLLOW THE INSTRUCTIONS CONTAINED IN THIS NOTICE FOR RESPONDING TO THIS OPPORTUNITY. The Federal Bureau of Prisons (FBOP), Central (CO), anticipates the need for indefinitedelivery indefinite-quantity (IDIQ), firm fixed-price contracts for supplemental architect-engineer (A-E) services, with a one (1) year base requirement and up to four (4) unilaterally exercised option years, with a possibility for a six-month extention as well. The Government is not obligated to exercise any of the option periods. While the Government anticipates multiple awards, no more than four (4) awards are expected. The services will be for various FBOP facilities throughout the United States. See the Statement of Work attachment for description of services. Most projects will take place in a fully occupied, fully operational, secure correctional environment. Most projects require complex design effort and detail along with extensive coordination between design disciplines, the institutions, and Central Office during design and construction. Firms are to perform services as required by the issuance of individual task orders. The guaranteed annual minimum amount of each contract is $10,000.00 and the estimated annual maximum is $10,000,000. The North American Industrial Classification System (NAICS) code applicable to this requirement is 541310 (Architectural Services). Interested firms must be registered in the System for Award Management (SAM) at https://SAM.gov. This requirement will be fulfilled pursuant to the Federal Acquisition Regulation (FAR) 36.6 and the Brooks Act. Pursuant to FAR Deviation 36.201(b), for any firm(s) receiving award under this requirement, no construction contract may be awarded to the firm (including any of its subsidiaries or affiliates) that designs the corresponding project Firms having the capabilities to perform the services described in this announcement are invited to respond by submitting Parts I and II of the Standard Form 330 (Architect Engineer Qualifications) dated not more than 12 months before the date of this synopsis. The current version of the form along with any extra pages/sections may be retrieved from www.gsa.gov/forms (Type in "SF330" in the Form Name or Number block for a full listing of the associated forms. *** Include a cover letter detailing your firms name and main office address (as registered in sam.gov), UEI#, Tax ID# (TIN), CAGE code, and main point of contact for your firm through out the solicitation process (phone and e-mail). Submissions should be on standard 8.5'' x 11" format. No extraneous attachments. Selection criteria will be based on the following evaluation factors in descending order of importance: Specialized Experience and Technical Competence (32%) Capacity to Accomplish the Work in the Required Time (demonstrated ability to complete projects on time) (27%) Acceptability of an Established Team of Key Personnel (23%) Professional Qualifications Necessary for Satisfactory Performance (including licensed engineers and architects licensed Nationwide)(18%) Submit details (maximum of one page per project) of not more than five significant and/or complex renovation projects completed in the past five years (Utilize Section F of the SF-330). Identify the lead designer and address the design approach with salient features for each project. Discuss how the client's program, function, image, mission, economic, schedule and operational objectives were satisfied by the overall design/planning solution. Include tangible evidence where possible such as certificates, awards, peer recognition, etc., demonstrating design excellence. Provide a client reference contact for each project, including name, title, address, phone, fax, and email. Submit resumes of key personnel outlining commitment to projects and qualifications and relevant experience as individuals and as a team. Highlight sustainability features incorporated into the project design (e.g., energy/water efficiency, waste reduction, use of recycled materials). Submit a narrative outline of not more than one page describing the firm's project management planning, coordination, scheduling and production facilities, capabilities, and techniques for both design and construction inspection (Utilize Section H of the SF-330). Submit a narrative outline (maximum one page) with examples describing the firm's ability to evaluate/develop accurate preliminary project budgets, ability to control project costs during design process, ability to design within funding limitations, methods used to coordinate construction documents, work of various engineering disciplines, and provide general production quality control (Utilize Section H of the SF-330). No fax or paper submissions. Submit electronically through the JEFS APP BOX at link below: https://jefs.app.box.com/f/336fbbe977394048827a238f901db3a3 All submissions should be in Adobe format. Title the file in the following format: 15BBNF26R70000006_ Company Name_SF330 Architect Engineer (A/E) Services for Central Office Electronic copies of each submission shall be compatible with the following software products: Adobe Acrobat Reader 11 and Microsoft Office Suite 2016. Narrative portions of the submission shall be in Adobe Acrobat portable document file (pdf) searchable text format. The Submitter shall not embed sound or video (e.g., MPEG) files into the submission files. Electronic files shall be clearly identified for each volume, section, and item. The Submitter must ensure electronic files are virus-free and shall run an anti-virus scan before submission. Submissions by mail or hand carried will not be evaluated. All responses must be received no later than Wednesday, November 4, 2026, 10:00 AM MST. It is the responsibility of the Submitter to confirm receipt by contacting Alex Jackson, Contracting Officer, at a4jackson@bop.gov. Failure to submit all required information may result in rejection. All submissions received after the exact time specified for receipt shall be treated as late submissions and will not be considered except under facts and circumstances allowed by the Federal Acquisition Regulations (FAR). Based on these submissions, a short-list of no more than six (6) firms will be selected for an interview. Firms should be prepared to discuss their submittals and to demonstrate their ability to fulfill the contract requirements. Final selection will be based on SF-330 submissions and interviews. After the SF-330 review and interview process, four (4) selected firms will be invited to submit a formal proposal and must be prepared to negotiate overhead, profit, and hourly rates for anticipated disciplines for use in negotiating firm-fixed-price contract rates as well as firm-fixed-price task orders to be completed under the contract. All contract awards and task orders thereunder are subject to a determination of fair and reasonable pricing. This acquisition is 100 percent small business set-aside. Firms must be registered in SAM.gov as a small business (see FAR provision 52.219-1 in the Representations & Certifications section of the SAM registration. If you have questions about SAM.gov, Government procurements in general, or need assistance in the preparation of your bid/proposal/offer, a local Procurement Technical Assistance Center (PTAC) may be able to help. The Procurement Technical Assistance Program was authorized by Congress in 1985 in an effort to expand the number of businesses capable of participating in the Government marketplace. To locate a PTAC near you, go to http://www.aptac-us.org. | - | Pre-Solicitation | 11/04/2026 |
Description The purpose of this announcement is to request new Architect / Engineer (A/E) qualification information for the General Services Administration / Public Buildings Service (GSA/PBS) A/E short selection for Continental United States (CONUS) and Outside Continental United States (OCONUS). WHAT IS THE SHORT SELECTION PROCESS? The short selection process utilizes the procedures set forth in Revolutionary FAR Overhaul (RFO) Federal Acquisition Regulation (FAR) Subsection 36.202-4 for Architect/Engineer (A/E) projects with an estimated total fee less than the simplified acquisition threshold (currently $350,000; see RFO FAR Part 2.101). The A/E's professional qualifications, the firm's geographic proximity, knowledge of the local area as identified on the A/E's SF330, and supplemental information will be used for the first preliminary screening of firms. For each proposed project, GSA will conduct discussions with at least three (3) firms to consider anticipated concepts and compare alternative methods for furnishing services. Additional information may be requested during discussions if necessary to facilitate the final ranking of firms (i.e.: past performance references, specialized experience, capacity, schedule, etc.). Upon conclusion of discussions, the top three firms will be ranked, and a price proposal will be requested from the highest ranked firm. If a fair and reasonable price cannot be negotiated with the highest ranked firm, a request for a price proposal will be sent to the second ranked firm, and so on until an award can be made at a fair and reasonable price. All acquisitions utilizing the GSA A/E short selection list (database) shall be set-aside for small business concerns unless requirements cannot be met by a small business and the Contracting Officer (CO) obtains a proper waiver. WHAT IS THE SHORT SELECTION PROCESS USED FOR? GSA will use the short selection list to award A/E contracts, valued at less than the simplified acquisition threshold (currently $350,000) in CONUS/OCONUS (NOT Estimated Cost of Construction at Award (ECCA). The firm must have NAICS code 541310 - Architectural Services, with a small business size standard of $12.5 million and/or 541330 - Engineering Services, with a small business size standard of $25.5 million. The firm must clearly notate which states/territories they have active production offices and which states they are licensed by November 1, 2026. Most work will be executed for repair and alteration projects within existing Federal Buildings and U.S. Courthouses. The estimated cost of construction at award (ECCA) for a majority of the project requirements could range from, but are not limited to, above micro-purchase threshold for construction (currently $2,000) to annual prospectus threshold (currently $3.961M) or higher. Fees for design services cannot exceed 6% of the ECCA. For more information about the 6% fee limitation, see FAR 15.404-9(c)(4)(ii) (GSA Class Deviation RFO-2025-15) and 41 U.S.C. 3905(b)(3). GSA manages a nationwide real estate portfolio of approximately 360 million rentable square feet, including preserving more than 500 historic properties nationwide. A broad range of services potentially requested under this short list may include, but are not limited to the following: 1. Core Project Life Cycle Services - These services cover the entire project lifecycle, from initial concept to post-construction closeout. Planning and Pre-Design Feasibility, pre-design, and project development studies Master planning Cost estimating Real estate market analysis Assessment and Investigation Existing conditions surveys, and field investigation Building condition survey evaluation reports (exterior and interior) Environmental investigation, reviews, inventories, and audits Energy audits and studies Design and Documentation Concept design, design development, and construction document development (both architectural and engineering) Interior design, including furniture, fixtures, and equipment (FFE) Building standard documents Construction Support and Closeout Constructability review and evaluation Submittal and shop drawing review Management and inspection (M&I) services during construction and construction inspection Building and system commissioning Post construction contract Services (PCCS); Record and close-out documents 2. Specialized Technical & System Design - Work requested often involves the assessment, repair, and upgrade of existing complex building systems. Mechanical, Electrical, and Plumbing (MEP) Full MEP services, including design of HVAC systems, electrical systems, and lighting Assessment and design for mechanical components (e.g., pumps, fans, air handlers, water distribution systems) and air distribution Design of water and waste water systems, including performance of sanitary inspections Temperature control assessment and design and BAS system assessment and integration Building Structure and Envelope Structural evaluation and design Façade evaluation and remediation design Water infiltration investigation and mitigation design safety, security, and compliance Fire and life safety evaluation and design Rehabs to improve energy efficiency and safety concerns Seismic & blast protection and vertical transportation Code compliance 3. A/E Disciplines and Expertise - A/E firms will need staff with licensed and/or specialized expertise. The following are typical disciplines and categories utilized for GSA projects. Firms do not need to have all of them, but should include the most relevant disciplines for their firm: Core Architectural and Engineering Disciplines Architecture and anterior architecture Mechanical engineering, electrical engineering, structural & civil engineering, and plumbing Historic architecture/preservation Specialized Expertise A qualified/licensed fire protection engineer (NCEES)* Security Space planning & workplace Cost estimating and scheduling Environmental services Building automation Scifs Modernization and Quality Control Building information modeling (BIM) Quality control review and report writing SUBMISSION INSTRUCTIONS To be considered for future Architect-Engineer (A/E) projects, your firm must submit a package demonstrating the applicability and comparability of its portfolio to the types of services outlined above. Please submit your complete package as a single PDF document. This file, which should be no larger than 30MB and no more than thirty (30) pages, must contain all submittal documents. Submit your PDF file as an attachment via the online “GSA A/E Short Selection Submission Form” (Link provided below). Note: Hardcopy submissions received by mail will not be filed or considered. The following information shall be submitted as part of the thirty (30) page limit (LISTED IN REQUIRED ORDER): DO NOT SUBMIT ANY PROPRIETARY INFORMATION 1. A cover letter. The letter should outline the work your firm specializes in and include a brief description of your firm's capabilities specifically related to the project examples stated above. 2. SAM Entity Registration Print Out - 1st and 2nd page only to show active registration in System for Award Management (SAM). Registration is required for award of federal contracts and you must have an active registration in SAM to be considered for project work. Contractors may register in SAM free of charge at https://sam.gov/ under the header labeled Register Your Entity or Get a Unique Entity ID. 3. Standard Form (SF) 330 - Architect-Engineer Qualifications. DO NOT include subconsultants. Please include photos of accomplished work. 4. A separate list of the licensed (or will be licensed by November 1, 2026) professionals and the State/territories of their licensing. Note: This A/E short selection process is for Primes only; consultants are NOT part of this selection process. However, submitted project experience may reference work executed with consultants. Firms should highlight their specific role and explain the work they performed alongside any consultants. Consultants will be requested by project managers during project development. Submittals that don't contain the required documentation will be returned for revision and/or non selection. Organizing your submittal package in the same order enumerated above will facilitate a more efficient review process. Questions related to this announcement shall be referred to aeshortselection@gsa.gov The following information should be easily found in your SF330 Submission: 1. Relevant Project Experience, Demonstrated Comparability and Creative Problem Solving Offerors must provide a minimum of three (3) but no more than five (5) comparable project examples that demonstrate a wide range of repair and alterations work similar in budgets and complexities to those anticipated for contracts. An additional maximum of ten (10) relevant projects completed in the last ten (10) years can be submitted in list form. Please include relevant project photographs. A comparable project is defined as an “A/E engagement involving the repair, alteration, or renovation of existing, occupied facilities, with a focus on both architectural and engineering solutions. Specifically, the project should demonstrate specialized experience in: Building system upgrades (e.g., MEP services or mechanical pump replacement) Historic preservation (especially classical building architecture) Workplace design Furthermore, a comparable project's Estimated Cost of Construction at Award (ECCA) should generally range from $50,000 to an annual prospectus threshold (currently $3.961M). Breadth of Scope: Teams must demonstrate proficiency in seamlessly incorporating architecture and engineering to solve both complex and routine design issues within existing buildings. Specialized Expertise: Highlight specialized experience in the areas most critical to the GSA/PBS mission. This must include work in: Occupied buildings Historic preservation, restoration, and adaptive reuse (special consideration will be given to firms demonstrating experience with classical building architecture and design) Building system upgrades (e.g., MEP services, mechanical pump replacement, HVAC systems, electrical systems, and building controls). Workplace design strategies, interior office redesign, and building standard documents Creative Problem Solving: Firms must demonstrate their ability to be creative and "think outside the box" when developing design solutions, especially given the constraints and challenges of government buildings and existing customer agencies while successfully navigating constraints such as schedule and budget. 2. Team Capacity, Management, and Quality Control The team’s ability to manage projects efficiently, flexibly, and collaboratively is essential for handling the unpredictable nature of GSA task orders. Contract Management and Flexibility: Demonstrate the ability to staff and manage contracts on an as-needed basis, accounting for the unpredictable issuance of work in terms of number, size, importance, and urgency. Consultant and Customer Agency Management: The A/E short selection process is for the Architecture or Engineering Prime only, but the firm must demonstrate its ability to manage its entire team. Firms must demonstrate proven success in establishing good relationships with and effectively managing future sub-consultants, as well as managing scope and communication while working with difficult customer agencies. Quality Assurance: Team must demonstrate formalized processes for quality control (QC) and a commitment to QC standards while consistently designing within the project’s budget and schedule limitations. 3. Key Personnel Education and Qualifications Key Personnel should possess the education, professional qualifications, and specific project experience that provides the best opportunity for the successful completion under this contract. Licensing: Provide a separate list of states in which the firm is licensed or will be licensed by November 1, 2026. Specialized Roles: Key Personnel must demonstrate expertise in disciplines relevant to the services outlined above, such as a Qualified Fire Protection Engineer1, historic preservation, etc. 1A Qualified Fire Protection Engineer is an individual with deep knowledge of fire physics and chemistry, meeting one of the following criteria: (a) An engineer with an undergraduate or graduate degree in fire protection/safety engineering, plus a minimum of four (4) years of relevant work experience; (b) A registered Professional Engineer (P.E. or similar) in Fire Protection Engineering; or (c) A P.E. in a related engineering discipline who is a Professional Member of the Society of Fire Protection Engineers and has passed the NCEES fire protection exam. 4. Past Performance Offerors should include CPARS (Contractor Performance Assessment Reporting System) if they have past government experience as the prime. No more than three (3) most recent relevant records. The CPARS information does not count against the thirty (30) page limit. Impact: If a firm does not have past government experience, they will not be negatively impacted during the selection process. Please register to attend the industry outreach and Q&A meeting on October 16 at 9am PDT or October 22 at 3pm EDT by completing the “A/E Short Selection Process Registration Form CONUS/OCONUS” (Link provided below). Invites will be sent out to all registered attendees approximately one week in advance. Relavant Links GSA A/E Short Selection Process for CONUS/OCONUS - Registration Form https://forms.gle/8kd1qZfZeVMag3HG9 GSA A/E Short Selection Process for CONUS/OCONUS - Q&A https://docs.google.com/document/d/1sGIs_KEnEvP99mxeB2VKBS64IVoUixEZSOLsczc_2As/edit?usp=sharing GSA A/E Short Selection Process for CONUS/OCONUS - Submission Form https://forms.gle/7Rh3FkMkubweUHveA | - | Market Research | 10/31/2026 |
Additional Details
Solicitation Number
VA-101-09-RP-0026
Archive Date
Mar 15, 2009
Office Address