Solicitation: Repair Fire Alarms Multi Facilities, JBPHH-HI
Archived on July 29, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 PM HST
- Posted
- July 24, 2026
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 561621: Security Systems Services (except Locksmiths)
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- NATIONAL GUARD BUREAU.JFHQ USPFO HI.USPFO HI PROCUREMENT.W7M4 USPFO ACTIVITY HIANG 154
- Place of performance
- JBPHH, Hawaii, 96853
- PSC
- J012: MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W50SLF26QA006
- Notice ID
- 4c43fdf435c04f6fa252d0c0bcbfc6b6
Description
07/24/2026: Amendment 0001 posted to incorporate Questions and Answers for solicitation W50SLF26QA006. See attachments. As confirmation of receipt, please update the highlight yellow portions of word document ‘Amendment 0001 Questions and Answers’ and return a copy to myself and the Contracting Officer, SMSgt de Veas with your RFQ offer or prior to RFQ offer due date.
----------------------
Questions regarding the solicitation are NO LONGER ACCEPTED at this time.
Quotes are due by 12:00 PM Hawaii Standard Time on Tuesday, 28 July, 2026. Electronic quotations must be submitted via e-mail to Emma Newbegin at emma.a.newbegin.civ@army.mil. Facsimile quotations will not be accepted.
SITE VISIT (CONCLUDED; NO ADDITIONAL SITE VISITS WILL BE SCHEDULED AT THIS TIME): A site visit will be conducted on Tuesday, 14 July 2026 At 0830 Hawaii Standard Time At 335 Gardner Ave, Bldg 3392, JBPHH-HI 96853. Use this google map link: https://maps.app.goo.gl/HEYYd4tAn5jwibrF9
IF YOU DO NOT HAVE BASE ACCESS PLEASE PROVIDE ATTENDEE NAME, PHONE NUMBER, AND COMPANY NAME to Garcia Rubio, Gonzalo Capt USAF (USA) via email at gonzalo.garcia_rubio.2@us.af.mil.
Information provided at this site visit as well as answers to questions shall not change/qualify the terms and conditions of this notice and specifications. Terms remain unchanged unless notice is amended in writing. If an amendment is issued, normal procedure relating to the acknowledgment and receipt of notice amendments shall apply.
REQUIREMENT SCOPE:
The Hawaii Air National Guard (HIANG) requires comprehensive assessment, repair, and inspection of fire alarm and suppression systems for multiple facilities at Joint Base Pearl Harbor-Hickam (JBPHH), HI. Several buildings have failed previous annual inspections and have known deficiencies that must be rectified before a re-inspection can be successfully completed. All work must be performed in accordance with applicable federal, state, and local fire codes and regulations, including UFC 3-601-02.
Scope of Work
The contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary to perform a comprehensive assessment, execute required repairs, and conduct post-repair operational testing and annual inspections for the fire alarm and life safety systems in the following buildings: 3376, 3382 (Main & Annex), 3380, 3379, 3392, and 3417.
The scope of work includes, but is not limited to, the following major tasks:
-
Fire Alarm Control Panel (FACP): Address "trouble" and "disable" statuses, and replace, program, and test FACPs in multiple buildings.
-
Transmitter & Antenna: Resolve communication issues and replace, program, and test transmitters and antennas.
-
System Components: Replace and test various system batteries, heat detectors, wiring, and sensors as required per building.
-
Fire Suppression System: Address and repair drain failures on a fire suppression riser.
-
Special Systems: Program and test a new walk-in refrigerator alarm system.
-
Inspection and Reporting: Upon completion of repairs, conduct a full annual inspection in accordance with NFPA 72 standards and submit detailed reports, including a completed NFPA 72 "Fire Alarm and Emergency Communication System Inspection and Testing Form" for each building.
-
Documentation: Provide pre-work submittals (e.g., material lists, safety plans, personnel qualifications) and post-work closeout documents (e.g., O&M manuals, warranty information, as-built drawings).
The work will be performed at the Hawaii Air National Guard Campus, Joint Base Pearl Harbor-Hickam (JBPHH), HI 96853.
Period of Performance
The estimated period of performance is 180 days, tentatively scheduled from September 1, 2026, to February 27, 2027.
Required Capabilities
Interested parties must demonstrate experience in the assessment, repair, and certification of complex fire alarm and suppression systems. All personnel performing technical work must meet the State of Hawaii's minimum licensing and certification requirements for Fire Alarm system technicians. A NICET (National Institute for Certification in Engineering Technologies) certification in Fire Alarm Systems is highly desirable.
Solicitations shall not exceed 5 pages, and provide the following:
One (1) signed copy of the Solicitation (SF1449)
Vender Name, Vendor POC, Vendor CAGE, Vendor UEI, Contact Ph#, E-mail, Discount terms (if applicable); Socio-Economic status; and completed Work Experience Form (attached).
Additionally, in order to be eligible for award, all respondents shall complete all Representations and Certifications found within their profile in the System of Award Management (SAM) at https://www.sam.gov.
Information provided from answers to questions shall not change/qualify the terms and conditions of the solicitation and specifications. Terms remain unchanged unless the solicitation is amended in writing. if an amendment is issued, normal procedure relating to the acknowledgment and receipt of solcitation amendments shall apply.
The Government intends to evaluate offers and award a contract WITHOUT discussions with offerors. Therefore, the offeror's inital offer should contain the offeror's best terms. [RFO FAR 52.212-1(d)].
A quoter which requires the Government to execute a separate agreement with a third party shall be deemed technically unacceptable.
Award Overview
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (6)
- Download
Amendment W50SLF26QA006 0001 Questions and Answers.docx
17 KBAdded in Solicitation version 7Posted - Download
QnA - KNMD260011 Fire Alarms Repair Services.pdf
129 KBAdded in Solicitation version 6Posted - Download
Solicitation - W50SLF26QA006.pdf
3.3 MBAdded in Solicitation version 4Posted - Download
ATCH 1 Drawings and Other Associated Project Documents.pdf
58 MBAdded in Solicitation version 4Posted - Download
ATCH 2 Wage Determination.txt
44 KBAdded in Solicitation version 4Posted - Download
ATCH 3 Work Experience Information.pdf
109 KBAdded in Solicitation version 4Posted
Lifecycle
- 3Version 3Sources SoughtArchived
Sources Sought for Repair Fire Alarms Multi Facilities, JBPHH-HI
- 4Version 4SolicitationArchived
Type changed from Sources Sought to Solicitation
Solicitation: Repair Fire Alarms Multi Facilities, JBPHH-HI
- 5Version 5SolicitationArchived
Solicitation: Repair Fire Alarms Multi Facilities, JBPHH-HI
- 6Version 6SolicitationArchived
Solicitation: Repair Fire Alarms Multi Facilities, JBPHH-HI
- 7Version 7SolicitationArchived
Solicitation: Repair Fire Alarms Multi Facilities, JBPHH-HI
- 9Version 9SolicitationArchivedCurrent
Solicitation: Repair Fire Alarms Multi Facilities, JBPHH-HI
Similar Opportunities
Additional Details
Solicitation Number
W50SLF26QA006
Archive Date
Jul 29, 2026
Office Address
KAPOLEI, HI, 96707-0000