Notice ID: 348ac5da38514f2d9149c5946c0892e5Presolicitation
NOTICE OF INTENT TO SOLE SOURCE � Equipment Maintenance Contract for Flash X-ray Systems and Computed Radiography Systems
Archived on November 17, 2020. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:59 AM UTC−05:00
- Posted
- November 2, 2020
- Notice type
- Presolicitation
- NAICS
- 334517: Irradiation Apparatus Manufacturing
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W6QK ACC-APG ADELPHI
- Place of performance
- Adelphi, MD, 20783
- Last updated
- Dec 4, 2025
Identifiers
- Solicitation number
- W911QX21R0006
- Notice ID
- 348ac5da38514f2d9149c5946c0892e5
Description
The United States Government intends to solicit and negotiate with only one source under the authority of FAR 6.302-1, Only One Responsible Source based on compatibility requirements, proprietary issues, and Original Equipment Manufacturer (OEM) certifications. The Government intends to solicit and negotiate with L-3 Applied Technologies, Inc., 2700 Merced St., San Leandro, CA 94577-5602, for an Indefinite Delivery Indefinite Quantity (IDIQ) type contract for equipment maintenance Contract for L-3 manufactured equipment. The proposed ordering period for this IDIQ contract will be for five (5) years which Firm Fixed Price (FFP) type delivery/task orders (TO) will be issued. This notice of intent is not a request for competitive proposals. However, any responsible source who believes it is capable of meeting the requirement may submit a capability statement, proposal, or quotation, which shall be considered by the agency, only if received by the closing date and time of this notice. A determination not to compete the proposed requirement based upon the responses to this notice is solely within the discretion of the Government. Requirement: The objective of this contract is to provide OEM supplies and services for Government-owned Flash X-ray Systems and Computed Radiography Systems. The supply portion consists of replacement and expendable items including but not limited to the following: x-ray tubes, 150 kilovolt (kV), 300 kV, 450 kV, 1 MV, Remote Tubehead Cables, Control cables, Remote Tubeheads, Modules, High voltage power supplies, XCON Trigger systems, Trigger Transformers, Charge Resistors, Flash X-ray Systems including standard add-on channels and options; 150 kV, 300 kV, 450 kV, 1 MV, CR Image plates and Cassettes, CR cleaning screens, CR image readers. The service portion consists of maintenance and/or replacement services including but not limited to pulser rebuilding, troubleshoot and repair flash x-ray equipment including: Trigger system malfunctions x-ray pulser malfunctions module and other high voltage component breakdowns, Factory repair of CR image readers and equipment modifications that consist of upgrades to existing system power supply and trigger systems, air conversion of existing 300 kV and 450 kV flash x-ray equipment, along with various components and assembly parts associated with -L3 Services.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
W911QX21R0006- Pre-Solicitation
Formal solicitation typically follows within 30–60 days. (estimate)
- Pre-SolicitationCurrentNov 2, 2020
NOTICE OF INTENT TO SOLE SOURCE � Equipment Maintenance Contract for Flash X-ray Systems and Computed Radiography Systems
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Source Measurement Units, Adapters and Test Fixtures for electronics measurement student labs. | 67% | Combined Synopsis | 11/17/2026 |
Reason for update is to change the set aside from N/ A to Total small business set aside. 1. LP6000 SYSTEM KIT-US Portable dual channels data acquisition base unit Detachable ruggedized controller LaserViewer Inspection Module-level 2, Soft key Wireless mouse Shipping case Documentation and manual kit AC Power cord US TYPE B 120V /10A AC Power Adapter for controller US TYP B 120V/10A FORUSE WITH LBIS /VBIS. Dimensions: 380 W x 200 H x 300 L [mm] (15 W x 8 H x 12 L [inch])Processor: Intel Core i7-1260P 12-Core/16-Thread 2.1 GHz Base/4.7 GHz TurboWeight: 12.4 Kg (27.3 lbs)Memory: 16GB DDR4 RAM; 3200 MHzPower: 110/240 VAC ? 50/60 Hz InternationalStorage (Internal)512GB PCIe 3.0x4 NVMe? SSDDisplay: Sunlight Readable Full HD LCD 13.3inch 1920x108 Environmental Specifications and CertificationsController UnitBase UnitOperating Temperature: -20?F - 145?F (-29?C - 63?C)Operating Temperature: Certified for 14?F - 122?F (-10?C - 50?C) per MIL-STD-810GHumidity: 95% RH, non-condensingHumidity: 0-90% non-condensing (equipment is not waterproof)IP Rating: IP66 certified IP Rating: Designed for IP54 MIL-STD-810H certifiedDrop and Vibration Certified per ASTM D4169 DC 13 Assurance Level II, Schedules A, E, F (within provided shipping case)MIL-STD-461G certified Vibration and 6 foot drop resistant2.Self-Propelled sensor delivery unit for 105-120mm camera/LVDT/LBIS? The SDU shall be capable of pushing or pulling the sensor 120mm sensors over an axial distance of no less than 8 meters (26.3 feet).? The SDU shall be provided with a muzzle adapter that is capable of being mounted to 105mm and 120mm gun tubes.? The SDU shall be capable of being interfaced with existing YPG-owned 105 mm and 120 mm LBIS (laser) sensors.? The SDU shall be provided with a flexible cable that includes a non-scratch protective cover.? The SDU shall be capable of allowing data acquisition over the full length of the 120 mm bore and up to the muzzle.? Linear resolution shall be 0.010? or better? Uni-directional position repeatability goal shall be 0.040? or better in | 61% | Combined Synopsis | 07/31/2026 |
Please see attachments | 61% | Solicitation | 11/23/2026 |
The 76 CMXG is requesting the utilization of funds for the procurement of Upgrade Xray controller and Automated Equipment. In accordance with AIR FORCE T.O 33B-1-2 (Table 3, Master List of Suppo1t Equipment), the system must be an approved equivalent to the X-Ray Apparatus Set (Master/Procmement NSN: MIL-PRF-32133/6635-01-394-5926). The required system must strictly adhere to the following component specifications: SYSTEM SPECIFICATIONS (Upgrade X-ray booth X-ray controller and automated equipment) • Hardware: Includes new servo motors, drives, operator control user interfaces, and manual controls hardware. • Software: Features programmable motion control software based on Parker Motion Systems libraries. It includes an intuitive interface for custom motion programs, automatic inspection positioning for repeatable programs, and digital image capture/save capabilities. • System Integration: The upgraded motion program will operate on the existing Vecow PC, interfacing directly with cmTent imaging software. INSTALLATION, TRAINING AND DOCUMENTATION • Installation & Training: Installation and a minimum of 4 homs of Operator and Maintenance Training onsite. (Covers travel, labor, shipping, and necessaiy bracketing hai·dwai·e to mount/remove equipment in the CMXG TSG X-ray System, with up to two (2) days onsite for installation, testing, debugging, and system acceptance). • Removal and Disposal of the existing equipment. • Documentation: Deliver three (3) complete sets of engineering manuals, which include drawings, schematics, and troubleshooting guides. | 61% | Pre-Solicitation | 11/05/2026 |
Solicitation number FA857927Q0006 is issued as a request for quote (RFQ) for the Keysight DC Power System. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. The 402d Software Engineering Group (402 SWEG) / 581st Software Engineering Squadron (581 SWES), located at Robins Air Force Base, Georgia, requires brand-name Keysight Technologies test instrumentation and modular power distribution equipment. This requirement directly supports organic depot-level maintenance, repair, calibration, and functional testing for the LGM-30G Minuteman III Intercontinental Ballistic Missile (ICBM) weapon system under the Depot Reentry Support Equipment Replacement Program (DRSERP). No foreign participation is permitted. Submission of a quotation in response to this RFQ is limited to contractors that are Keysight Technologies approved resellers and distributors. Submissions should only be sent to the Contracting Officer: Jonathon VanBrunt; jonathon.vanbrunt@us.af.mil Please note this is a DX-A1 DPAS rated requirement. | 60% | Solicitation | 11/17/2026 |
Additional Details
Solicitation Number
W911QX21R0006
Archive Date
Nov 17, 2020
Office Address
ADELPHI, MD, 20783-1197