Lower Monumental PH HVAC System Upgrade
Archived on October 20, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM PDT
- Posted
- September 29, 2026
- Notice type
- Solicitation
- Set-aside
- No Set aside used
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION NORTHWESTERN.ENDIST WALLA WALLA.US ARMY ENGINEER DISTRICT WALLA WAL
- Place of performance
- Kahlotus, Washington, 99335
- PSC
- Y1KA: CONSTRUCTION OF DAMS
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W912EF26RA007
- Notice ID
- e217a7fed88c47d1abee64d52bd8ad5b
Description
OVERVIEW:
The work is located at the Lower Monumental Dam Powerhouse, Kahlotus, Washington. This solicitation is being issued as a Lowest Price Technically Acceptable (LPTA) Request for Proposal (RFP) and will result in a single firm-fixed price construction contract. This procurement is unrestricted. Competition is open to both large and small business concerns. A small business subcontracting plan is required for large businesses. 100% performance and payment bonds are required for this project. The North American Industry Classification System (NAICS) code for this project is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, and the associated small business size standard is $19,000,000.
System for Award Management (SAM): Offerors must register in SAM at: https://SAM.gov/content/home prior to receiving an award.
SCOPE OF WORK:
The work will provide a modernized HVAC system that will ventilate, heat, and cool the spaces in the powerhouse using river water for both heating and cooling sources. The new system must allow for efficient powerhouse pressurization to reduce smoke and dust ingress into the powerhouse, prolonging equipment life for many assets and providing for good indoor air quality for occupants. The occupied spaces must be provided with sufficient ventilation, comfort heating and comfort cooling. The control room and stairwells must be provided with a system that will be capable of pressurizing those spaces with clean outside air for the exclusion of smoke during a fire event anywhere in the powerhouse in addition to providing sufficient ventilation, comfort heating and comfort cooling. Update the HVAC control system to a modern electronic control system which can be operated from the control room to significantly reduce the effort required to operate the system. Provide permanent access platforms for efficient access to system components for maintenance, such as the maintenance of the dampers in the mixed air plenum and replacement of air filter media in the perceptron room.
THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THE SOLICITATION EITHER BEFORE OR AFTER THE CLOSING DATE. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS PRE-SOLICITATION NOTICE OR ANY FOLLOW-UP INFORMATION REQUEST.
The Contractor will be responsible for establishing and managing an effective Contractor Quality Control (CQC) System that will require the development and submission of a comprehensive project specific CQC Plan for Government acceptance. A CQC System Manager employed by the prime contractor shall be required to be on-site for each shift of the Contractor's operations. The CQC System Manager must possess a minimum of 5-years ‘ relevant experience in a supervisory or management position such as Quality Control Manager, Quality Assurance Manager, or Construction Manager directly involved in the management of construction quality at the project site. In addition, the CQC System Manager shall have completed the course entitled "Construction Quality Management for Contractors" within the last 5-years.
The project will involve the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract.
Please send your proposal by email to: nathan.i.bruce@usace.army.mil
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Files (11)
- Download
A.02.11 Technical Specifications (Amend 0003).pdf
36 MBAdded in Solicitation version 10Posted - Download
A.03.09 Drawings (Amend 0003).pdf
6.5 MBAdded in Solicitation version 10Posted - Download
B.08.03 Solicitation (Amend 0003).pdf
611 KBAdded in Solicitation version 10Posted - Download
B.08.03 Solicitation (Amend 0002) CONFORMED.pdf
12 MBAdded in Solicitation version 8Posted - Download
A.03.09 Supplemental Drawings (26RA007).pdf
519 KBAdded in Solicitation version 7Posted - Download
KTR Site Visit List.pdf
89 KBAdded in Solicitation version 6Posted - Download
B.08.03 Solicitation (Amend 0001).pdf
34 MBAdded in Solicitation version 5Posted - Download
A.03.09 Plans (26RA007).pdf
54 MBAdded in Solicitation version 4Posted - Download
B.08.02 Solicitation (26RA007).pdf
37 MBAdded in Solicitation version 4Posted - Download
A.03.09 Drawings (26RA007).pdf
15 MBAdded in Solicitation version 4Posted - Download
A.02.11 Technical Specifications (26RA007).pdf
4.0 MBAdded in Solicitation version 4Posted
Lifecycle
- 3Version 3PresolicitationArchived
Lower Monumental PH HVAC System Upgrade
- 4Version 4SolicitationArchived
Type changed from Presolicitation to Solicitation
Lower Monumental PH HVAC System Upgrade
- 5Version 5SolicitationArchived
Lower Monumental PH HVAC System Upgrade
- 6Version 6SolicitationArchived
Lower Monumental PH HVAC System Upgrade
- 7Version 7SolicitationArchived
Lower Monumental PH HVAC System Upgrade
- 8Version 8SolicitationArchived
Lower Monumental PH HVAC System Upgrade
- 10Version 10SolicitationArchivedCurrent
Lower Monumental PH HVAC System Upgrade
Similar Opportunities
Additional Details
Solicitation Number
W912EF26RA007
Archive Date
Oct 20, 2026
Office Address
WALLA WALLA, WA, 99362-1876