GovChime
Notice ID: d3f1cb94013b4a338053516e9c32d7cfSources Sought

6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software

Archived on November 7, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
7:00 AM EDT
Posted
August 27, 2026
Notice type
Sources Sought
Set-aside
Small Business Set Aside - Total
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Place of performance
VAMC CLEVELAND 10701 EAST BLVD., CLEVELAND, Ohio, 44106
Last updated
Nov 7, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25026Q0950
Notice ID
d3f1cb94013b4a338053516e9c32d7cf

Description

SOURCES SOUGHT NOTICE THIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a). DISCLAIMER This request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement. SOURCES SOUGHT DESCRIPTION The Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories for Surgical Department Mechanical Room that meets the following: Product/Items ITEM NO. DESCRIPTION QUANTIYT UNIT OR STOCK NO. Request purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3) Accommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor 1 EA 2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions 1 EA 3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST) 1 EA 4. Shipping and Handling 1 EA Specifications & Salient Characteristics Technical Specifications Refraction (vertical meridian): Binocular and monocular measurement Spherical range: +5.00 D to 7.00 D, in increments of 0.01 D Pupil size: Range: 4.0 8.0 mm, measured in 0.1 mm steps, ±10% accuracy Pupil distance (interpupillary distance): Measured in 1.0 mm steps, ±10% accuracy Sampling rate: 50 Hz (one measurement every 20 ms) Measuring distance: Standard working distance of 1 m (± 5 cm) Measurement principle: Binocular, dynamic photoretinoscopy Interfaces & Power Requirements Interfaces: 4 × USB ports 1 × VGA output (supports 1024 × 768 resolution) Power supply: AC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor) Environmental Conditions Operating temperature: 10 35 °C (50 92 °F) Storage temperature: 0 50 °C (32 122 °F) Relative humidity (non-condensing): Operating: 20 80% Storage: 10 85% Data Output & Logging Measurements are continuously recorded into a CSV logfile, capturing: Timestamp (every 20 ms) LED brightness (percentage) Pupil detection status (found/not found) Pupil size (width & height in mm) Pupil brightness (digital units 0 255) Purkinje reflex size & position (pixels: X & Y) Gaze angles (horizontal & vertical in degrees) Spherical refraction per eye, including mean & standard deviation over last 10 frames Interpupillary distance in mm Camera horizontal angle Salient Functional Characteristics Binocular dynamic measurement: Tracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes 50 Hz real-time sampling: High temporal resolution enables precise tracking of fast dynamics Open-field fixation: Uses a hot mirror to allow naturalistic visual targets at any distance Non-contact operation: Measurements gathered without touching the subject Research-grade device: Designed specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics Integration & Output Data can be streamed via USB or recorded to a VGA-connected monitor Outputs are ideal for integration into custom research setups and signal logging systems Salient Characteristics Plusoptix PowerRef 3 Accommodation Measurement System The PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement: 1. Measurement Capability Must perform simultaneous binocular measurement of: Refractive state (sphere, vertical meridian) Convergence/vergence Pupil size (both eyes) Must provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis. 2. Sampling and Data Output Must provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations. Must support continuous data streaming and export to external computers and research software. Must allow real time or recorded output in spreadsheet compatible formats. 3. Optical and System Design Must use infrared photorefraction technology. Must include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path. Must incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances. 4. Calibration and Reliability Must be engineered for long term calibration stability, requiring no routine recalibration under normal use. Must include durable optics and electronics suited for repeated daily research use. 5. Fixation Target Flexibility Must support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing. 6. Integration and Compatibility Must be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs. Must allow USB or networked connection for external data handling. 7. System Configuration Must include all necessary hardware, software, cables, and accessories required for full operational use upon installation. Background: The VA-ORD-funded study Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence. Scope: Acquisition of an automated retinoscopy-based accommodation and ocular vergence measurement device, its control software, and associated measurement apparatus.   The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.) Is your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code? Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items? If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). If you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract? Please provide general pricing of your products/solution for market research purposes. Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes. No re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM. SUBMISSION Responses to this notice shall be submitted via email to kevin.peeples@va.gov and robert.blasko@va.gov referencing 36C25026Q0950 in the email. Telephone responses will not be accepted. Responses must be received no later than September 8, 2026, at 7:00am EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. CLAUSES FAR Number Title Date 52.209-6 PROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT JAN 2025 52.212-4 CONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS NOV 2023 52.222-90 52.232-33 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS PAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT APR 2026 OCT 2018 52.252-2 CLAUSES INCORPORATED BY REFERENCE FEB 1998 52.232-40 PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS MAR 2023 52.233-1 DISPUTES MAY 2014 52.233-3 PROTEST AFTER AWARD AUG 1996 852.219-76 852.203-70 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION) COMMERCIAL ADVERTISING JAN 2023 MAY 2018 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS NOV 2018 852.237-70 CONTRACTOR RESPONSIBILITIES OCT 2019 PROVISIONS 52.212-1 INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS SEP 2023 52.212-2 EVALUATION--COMMERCIAL ITEMS NOV 2021

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Aug 26, 2025

NAICS

339112

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

KEVIN PEEPLES
CONTRACT SPECIALIST
Fax: NA

Documents

Files (1)

  • 36C25026Q0950.docx

    39 KBAdded in Sources Sought version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Sources SoughtCurrent

    6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software

    Notice d3f1cb94013b4a338053516e9c32d7cf on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Combined Synopsis/Solicitation Notice *= Required Field Combined Synopsis/Solicitation Notice DESCRIPTION This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. This solicitation is a Small Business set-aside. The associated North American Industrial Classification System (NAICS) code for this procurement is 339112. The FSC/PSC is 6515. The NCO 10 for Cleveland VA Medical Center is seeking to purchase the Olympus BX Microscope for the Cytology Department. This solicitation closes on September 25, 2026 @ 13:00 AM. Quotes should be submitted to Kevin Peeples kevin.peeples@va.gov Please reference 36C25026Q1066 1. Contracting Officer s Representative (COR NA 2. CONTRACT TITLE: BX43-1-3 Cytology Microscopes 3. BACKGROUND The Department of Veterans Affairs Northeast Ohio Healthcare System (VANEOHS) has an immediate requirement for the procurement of two (2) brand name Evident (formerly Olympus) BX43-1-3 cytology microscopes, inclusive of the True Color LED light source compatible with BX43F, BX46F, and BX63F platforms, and all required Original Equipment Manufacturer (OEM) components and accessories necessary for full clinical activation and use. The requested microscopes are additional units to the currently deployed Evident BX-series microscopes within the Cytology Section of Pathology & Laboratory Management Services (PALMS). The laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational protocols, and preventative maintenance programs are fully based upon the Evident BX-series platform. The Cytology laboratory s diagnostic workflows, digital imaging systems, standardized operating procedures, educational platforms, and preventative maintenance programs are built upon the BX-series architecture. The Cytology Section performs high-resolution visualization and evaluation of: Cellular morphology Cytological abnormalities Microbiological organisms Inflammatory processes Neoplastic pathologies These diagnostic evaluations are mission-critical to accurate, timely, and actionable patient diagnoses. This acquisition is required to maintain full operational capacity, mitigate diagnostic backlog, maximize utilization of existing Government-owned assets, and ensure uninterrupted cytopathology services. 4. SCOPE The Contractor shall provide two (2) new, current production BX43-1-3 microscopes, inclusive of the True Color LED light source and all requested and associated OEM components, accessories, modules, assemblies, and consumables required for immediate clinical deployment within the Cytology Section. The Contractor shall provide on-site installation, configuration, and operational verification of all microscopes and associated OEM components at the Louis Stokes Cleveland VA Medical Center, Pathology & Laboratory Management Services Cytology Section. Installation shall include full assembly, alignment of optical components, calibration of the illumination system, verification of mechanical stage functionality, confirmation of imaging integration (if applicable), and validation of overall system performance for clinical diagnostic use. All equipment shall be fully operational and ready for immediate patient care application upon completion of installation. Any deficiencies identified during installation or inspection shall be corrected by the Contractor at no additional cost to the Government prior to final acceptance. The microscopes and components shall meet or exceed the following operational, optical, interoperability, and performance requirements: Optical and Imaging Performance: UIS2 infinity-corrected optical system Plan Apochromat or Plan Fluorite objectives optimized for cytology applications High numerical aperture objectives suitable for oil immersion cytopathology 100x oil immersion capability Wide field number (FN 22 or greater) High-resolution visualization suitable for evaluation of cellular morphology, cytologic abnormalities, infectious organisms, and neoplastic processes OEM camera adapter compatibility for integration with existing digital imaging systems Illumination System: True Color LED light source compatible with BX43F, BX46F, and BX63F Daylight-balanced illumination to support accurate cytologic color interpretation Flicker-free, stable output LED lifespan 20,000 hours Intensity memory function Uniform illumination across full field of view Ergonomic and Mechanical Features: Ergonomic observation tube with adjustable inclination Low-position coaxial focus knobs Coarse and fine focus with tension adjustment Precision mechanical stage with fine movement control Stage inserts compatible with cytology slide preparation Configuration optimized for prolonged microscopic review Required OEM Accessories and Components: The Contractor shall provide all OEM components necessary to ensure full functionality and activation, including but not limited to: Proprietary stage inserts Light modules Camera adapters Immersion oil kits (OEM approved) Dust covers Power cords Calibration and setup materials Required mounting hardware Any additional OEM components necessary for clinical operation All components must be new, OEM-manufactured, and fully compatible with existing Evident BX-series microscopes currently deployed within the laboratory. Interoperability Requirements: The Cytology Section is standardized on the Evident BX-series microscope platform. All diagnostic workflows, imaging protocols, training materials, and maintenance programs are built upon this system. The requested microscopes are additional to the currently deployed fleet and must: Integrate seamlessly with existing BX-series equipment Maintain optical consistency across the microscope fleet Preserve manufacturer warranty protections Support existing service contracts and maintenance protocols Require no retraining due to platform change Non-OEM or alternate-brand equipment would: Disrupt standardized diagnostic workflow Introduce optical variability affecting diagnostic consistency Invalidate manufacturer warranties Require retraining of cytotechnologists and pathologists Undermine fleet uniformity and serviceability Warranty: Equipment shall include the manufacturer s standard warranty covering optical, mechanical, and illumination systems for a minimum of one (1) year. 6. Performance Monitoring The Government will monitor contractor performance to ensure compliance with all requirements outlined in this Statement of Work. Performance monitoring will include verification of timely delivery, proper installation, system functionality, completion of required training, and successful commissioning of the equipment in accordance with manufacturer specifications. Government representatives, including Pathology & Laboratory Medicine Service personnel and designated technical staff, will validate that the system operates as intended and meets operational and functional requirements prior to acceptance. Any deficiencies identified during delivery, installation, or operational verification shall be corrected by the Contractor at no additional cost to the Government. The Contractor shall coordinate all activities with the designated Government point of contact to ensure minimal disruption to laboratory operations and adherence to agreed installation schedules. 7. Security Requirements The C&A requirements do not apply, and the Security Accreditation package is not required for this SOW. 8. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). There will be no government-Furnished equipment of information. 9. Other Pertinent Information or Special Considerations. The requested equipment shall be interoperable/usable with current workflows and technology deployed and used within the clinical atmosphere and existing BX Microscopes and associated accessories. a. Identification of Possible Follow-on Work. NA b. Identification of Potential Conflicts of Interest (COI). NA c. Identification of Non-Disclosure Requirements. NA d. Packaging, Packing and Shipping Instructions. NA e. Inspection and Acceptance Criteria. Government acceptance will occur upon: Successful installation Demonstrated operational functionality Completion of training if applicable Readiness for clinical laboratory use 10. Place of Performance. Delivery Location: Louis Stokes Cleveland VA Medical Center Pathology & Laboratory Management Services Cytology 10701 East Boulevard Cleveland, OH 44106 11. Period of Performance NA 12. Delivery Schedule. The Contractor shall deliver all required equipment and system components within ninety (90) calendar days from the date of contract award. Installation, configuration, and commissioning activities shall be coordinated with Government personnel and completed within the same 90-day period unless otherwise agreed upon in writing by the Contracting Officer. SUBMISSION Responses to this solicitation shall be submitted via email to kevin.peeples@va.gov. Telephone responses shall not be accepted. Responses must be received no later than September 25 2026, at 13:00 pm EST, (Eastern Standard Time). CLAUSES FAR Number Title Date 52.209-6 PROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT JAN 2025 52.212-4 CONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS NOV 2023 52.222-90 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS APR 2026 52.232-33 PAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT OCT 2018 52.252-2 CLAUSES INCORPORATED BY REFERENCE FEB 1998 52.232-40 PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS MAR 2023 52.233-1 DISPUTES MAY 2014 52.233-3 PROTEST AFTER AWARD AUG 1996 852.219-76 852.203-70 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION) COMMERCIAL ADVERTISING JAN 2023 MAY 2018 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS NOV 2018 852.237-70 CONTRACTOR RESPONSIBILITIES OCT 2019 PROVISIONS 52.212-1 INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS SEP 2023 52.212-2 EVALUATION--COMMERCIAL ITEMS NOV 2021
-Combined Synopsis09/25/2026
Digital Non-Mydriatic Fundus Camera System This announcement requests information from industry to support market research and preliminary acquisition planning for the procurement of (1) one digital non-mydriatic fundus camera system with retinal image-capture software and vendor installation for the new East Indianapolis VA Clinic Tele-Eye Screening room. Of particular interest is identifying products that are made in America and meet the domestic end-product test of FAR 25.101. This is not a solicitation for proposals. No contract will be awarded from this notice. REQUIREMENT The agency is seeking information on sources of supply for one digital non-mydriatic fundus camera system with retinal image-capture software. Description: Compact, non-mydriatic digital retinal imaging system designed to acquire high-resolution color and fundus autofluorescence images of the human retina. The system shall support screening, documentation, and monitoring of ocular conditions without routinely requiring pharmacological pupil dilation. Salient Characteristics: Shall provide color retinal photography and fundus autofluorescence imaging. Shall produce retinal images with a resolution of at least 32 megapixels. Shall use infrared light for patient alignment and focusing before image capture. Shall acquire images through pupils approximately 3.3 mm in diameter or smaller without routinely requiring dilation. Shall provide automated alignment, focusing, exposure adjustment, image capture, and switching between anterior-eye and retinal observation. Shall permit the operator to override automatic focusing and manually adjust focus when necessary. Shall automatically evaluate image focus and eye alignment and alert the operator when image quality is insufficient. Shall provide digital image-processing modes capable of emphasizing retinal vascular and structural features, including red-free and blue-spectrum viewing modes. Shall include contrast-enhancement processing to improve differentiation between retinal blood vessels and surrounding tissue. Shall use low-intensity flash illumination to minimize pupil constriction and support sequential image acquisition. Shall provide adjustable image-sensitivity settings covering a range equivalent to ISO 200 through ISO 6400. Shall include an integrated display that allows the operator to preview and verify captured images at the imaging device. Shall include a complete retinal image-capture and management software package supporting image acquisition, patient-data entry or import, image review, processing, storage, and export of retinal images and associated patient information in DICOM and commonly used image formats. The software shall support DICOM worklist and electronic medical record integration when properly configured. Minimum of one-year manufacturer warranty coverage. Interested parties who can provide a product that meets the description above are requested to submit the following information: Product information documenting salient characteristics, Company name, address and point of contact with phone number, SAM Unique Entity Identifier (UEI), Place of manufacture, Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc., Any other pertinent company documentation. Note: All interested parties must be registered in SAM (System for Award Management) to be eligible for the award of a future Government contract. Send submissions to Brian.Rosciszewski@VA.gov., reference 36C25027Q0097 in email subject. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. Respondents may not be notified of the results of this notice; it is at the discretion of the Government to release any results. Thanks in advance for your time and consideration in supporting America s veterans. ** End of Sources Sought Notice **
-Market Research11/13/2026
-AwardedOpen
JUSTIFICATION POSTING
-Sole Source / J&AOpen
Brand Name Only, Unrestricted RFQ for Hemosphere Alta Bundle.
-Combined Synopsis09/24/2026

Additional Details

Solicitation Number

36C25026Q0950

Archive Date

Nov 7, 2026

Office Address

DAYTON, OH, 45428