GovChime
Notice ID: 91bdcba4bb0446ba9869a33cf76dc7a9SolicitationArchived

B118 Fire Panel

Archived on September 25, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM EDT
Posted
September 2, 2026
Notice type
Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
238210: Electrical Contractors and Other Wiring Installation Contractors
Agency
Department of WarDepartment of the Army

Notice details

Office
NATIONAL GUARD BUREAU.JFHQ USPFO OH.USPFO OH PROCUREMENT.W7NU USPFO ACTIVITY OHANG 180
Place of performance
Swanton, Ohio, 43558
PSC
N063: INSTALLATION OF EQUIPMENT- ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W50S8S26QA013
Notice ID
91bdcba4bb0446ba9869a33cf76dc7a9

Description

Solicitation has been amended: Quoters must acknowledge amendment in section 19.

Amendment 1 (2 September 2026):

Request for Information (RFIs) have been received and answered. Q&A Document is attached to this posting along with the new 1442 acknowledging the amendment to include Q&As. Additionally, the offers due date has been changed from 3 September 2026 at 10 AM Eastern to 10 September 2026 10 AM Eastern time. This change allows time for acknowledgement of the amendment.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~

The 180th Fighter Wing is issuing a Request for Quotes to award a single firm fixed-price contract for commercial construction services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, and supervision necessary for roof repairs on buildings 101 and 136, located at the 180th Fighter Wing (FW), Swanton, Ohio Air National Guard Base. This project includes a Brand Name requirement for the fire panel (Monaco) and the justification is attached to this posting. Objective is 

Phase 1 – Design & Demolition:

  • Provide a complete, stamped Fire Protection System design from a NICET certified designer.
  • Demo the existing Simplex Panel, carefully labeling all inputs and outputs for transfer to the new system.
  • Demo the existing Monaco M-2 Panel, carefully labeling all inputs and outputs.
  • Demo the existing Monaco BT2-8, antenna, and lightning arrestor.

Phase 2 – FACP Installation and Upgrade:

  • Install a new Monaco MAPP X panel, complete with all necessary expansion cards and devices to accommodate all existing and new equipment.
  • Install a new NFPA-compliant battery backup system and cabinet.
  • Install a new antenna and lightning arrestor system for the new panel.
  • Replace approximately 90 existing smoke detectors with new, compatible models.
  • Replace approximately 12 existing heat detectors.
  • Replace approximately 4 existing duct detectors.
  • Replace approximately 18 existing pull stations.
  • Replace approximately 22 existing horn strobes.
  • Install all new copper wiring as required to connect all devices to the new FACP.
  • Fully program the new FACP to manage all connected initiating and notification devices.
  • Perform a complete 100% functional and acceptance test of the entire system in accordance with NFPA and UFC standards, to be witnessed by the COR and Base Fire Department.

In accordance with the attached Performance Work Statement. 

The contract duration will be 90 days after award. This project is set aside 100% for Small Business. The North American Industry Classification (NAICS) Code is 238210, with a size standard of $19,000,000.00. The magnitude is between $25,000 and $100,000. 

Alternative payment protections apply under clause 52.228-13. The contractor shall submit one of the following payment protections: An irrevocable letter of credit (ILC), A tripartite escrow agreement, Certificates of deposit, or a payment bond. The amount of the payment protection shall be 100 percent of the contract price. The submission of the payment protection is required within 10 days of contract award. The payment protection shall provide protection for the full contract performance period plus a one-year period. Except for escrow agreements and payment bonds, which provide their own protection procedures, the Contracting Officer is authorized to access funds under the payment protection when it has been alleged in writing by a supplier of labor or material that a nonpayment has occurred, and to withhold such funds pending resolution by administrative or judicial proceedings or mutual agreement of the parties. When a tripartite escrow agreement is used, the Contractor shall utilize only suppliers of labor and material that signed the escrow agreement.

An optional site visit will be held on Wednesday August 26th, 9am local time, at the 180th Fighter Wing 2660 S Eber Rd, Swanton, Ohio 43558. Interested parties are required to RSVP to 180.fw.contracting@us.af.mil with the number of visitors attending, names, and company information by Tusday August 25th, 4pm local time. REAL ID drivers license is required for access to the installation, those without compliant identification will not be allowed on base. 

Any questions related to this posting can be sent to 180.fw.contracting@us.af.mil. 

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

TSgt Cody Walker

Secondary Contact

2d Lt Adam Krouse

Documents

Files (7)

  • Solicitation Amendment - W50S8S26QA0130001.pdf

    6.2 MBAdded in Solicitation version 3Posted
    Download
  • Solicitation Amendment W50S8S26QA0130001 SF 30.pdf

    3.8 MBAdded in Solicitation version 3Posted
    Download
  • 180th_fw_rfi_responses.pdf

    64 KBAdded in Solicitation version 3Posted
    Download
  • Solicitation - W50S8S26QA013.pdf

    7.3 MBAdded in Solicitation version 1Posted
    Download
  • PWS for B118 Fire Panel Install.pdf

    233 KBAdded in Solicitation version 1Posted
    Download
  • Limited Competition Justification - Brand name_Redacted.pdf

    325 KBAdded in Solicitation version 1Posted
    Download
  • Wage rates.pdf

    43 KBAdded in Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    B118 Fire Panel

    Notice d8980950a7dc4946a742e543052b8fec on SAM.gov

  2. 3
    Version 3SolicitationArchivedCurrent

    B118 Fire Panel

    Notice 91bdcba4bb0446ba9869a33cf76dc7a9 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

W50S8S26QA013

Archive Date

Sep 25, 2026

Office Address

SWANTON, OH, 43558-9645